Fabrication of Ceramic Membrane Chromatography for Biologics Purification

Chromatography is one of the most important separation processes of choice for the recovery/purification of proteins and complex bio-structures. Fabrication of chromatographic membranes and their efficiency in the chromatography process has been the subject of many recent researches. In this study,...

Full description

Bibliographic Details
Main Authors: Maizirwan Mel, Fouad R.H. Abdeen, and Iis Sopyan
Format: Article
Language:English
Published: IIUM Press, International Islamic University Malaysia 2011-12-01
Series:International Islamic University Malaysia Engineering Journal
Online Access:http://journals.iium.edu.my/ejournal/index.php/iiumej/article/view/213
id doaj-95eddd7ac3d94a7381f15f5d5a28f88e
record_format Article
spelling doaj-95eddd7ac3d94a7381f15f5d5a28f88e2020-11-25T03:17:44ZengIIUM Press, International Islamic University MalaysiaInternational Islamic University Malaysia Engineering Journal1511-788X2289-78602011-12-0112410.31436/iiumej.v12i4.213Fabrication of Ceramic Membrane Chromatography for Biologics PurificationMaizirwan Mel0Fouad R.H. Abdeenand Iis SopyanInternational Islamic University Malaysia; P.O. Box 10, 50728 Kuala Lumpur Chromatography is one of the most important separation processes of choice for the recovery/purification of proteins and complex bio-structures. Fabrication of chromatographic membranes and their efficiency in the chromatography process has been the subject of many recent researches. In this study, a coin-like, 13 mm diameter and 3 mm thick, ceramic membrane was fabricated to be used as a chromatographic medium. The membrane is used to replace the conventional resin-based chromatography columns. Hydroxyapatite (HA) powder was used as a material for the membrane fabrication. In this project, a HA powder was produced using starch as pore creating agents. Characterization processes were done for the ceramic membrane using the suitable apparatuses. Three parameters of the fabrication process (starch wt %, compaction pressure and sintering temperature) were manipulated to optimize the performance of the membrane. The fabricated membrane was placed in a (FPLC) system to be tested for its performance as an adsorptive membrane. (IMAC) process was run by immobilizing Ni2+ ions at the membrane particles surfaces. NP protein of the (NDV) was used to test the membrane's ability to bind Histidine-tagged proteins. The optimum set of process parameters that yielded in the highest porosity and good chromatogram was determined to be 5 wt % starch, 3000 psi compaction pressure and 1100°C sintering temperature. ABSTRAK: Kromatografi merupakan satu daripada proses pengasingan yang penting yang dipilih untuk perolehan/penapisan protein dan biostruktur yang kompleks. Pemfabrikatan membran kromatografi dan kecekapannya dalam proses kromatografi merupakan fokus beberapa kajian terkini. Dalam kajian ini, membran seramik berbentuk duit syiling, berdiameter 13 mm dengan ketebalan 3 mm, direka untuk digunakan sebagai perantara kromatografi. Membran ini digunakan untuk menggantikan turus kromatografi berasaskan resin yang lazim. Serbuk hidroksiapatit (HA) digunakan sebagai bahan pemfabrikatan membran. Dalam projek ini, serbuk HA dihasilkan menggunakan kanji sebagai agen penghasilan liang. Proses pencirian dilakukan terhadap membran seramik menggunakan radas yang sesuai. Tiga parameter proses pemfabrikatan (peratusan berat kanji, tekanan padatan dan suhu pensinteran) dimanipulasikan untuk mendapatkan prestasi membran yang optima. Membran yang difabrikatkan diletakkan dalam sistem FPLC (Fast Protein Liquid Chromatography) untuk diuji prestasinya sebagai membran serap. Proses IMAC (Immobilized Metal Affinity Chromatography) dijalankan dengan memegunkan ion Ni2+ pada permukaan zarah membran. Nucleoprotein dari NDV (Newcastle disease virus) digunakan untuk menguji kebolehan membran terikat dengan protein yang dilabelkan dengan Hisditina. Set parameter proses yang optima yang menghasilkan keliangan tertinggi dan kromatogram yang baik ditentukan pada berat kanji 5 %, tekanan padatan 3000 psi dan suhu pensinteran 1100°C. KEYWORDS: Membrane Chromatography, Porous Ceramic Membrane, IMAC, Hydroxyapatite, Chromatography. http://journals.iium.edu.my/ejournal/index.php/iiumej/article/view/213
collection DOAJ
language English
format Article
sources DOAJ
author Maizirwan Mel
Fouad R.H. Abdeen
and Iis Sopyan
spellingShingle Maizirwan Mel
Fouad R.H. Abdeen
and Iis Sopyan
Fabrication of Ceramic Membrane Chromatography for Biologics Purification
International Islamic University Malaysia Engineering Journal
author_facet Maizirwan Mel
Fouad R.H. Abdeen
and Iis Sopyan
author_sort Maizirwan Mel
title Fabrication of Ceramic Membrane Chromatography for Biologics Purification
title_short Fabrication of Ceramic Membrane Chromatography for Biologics Purification
title_full Fabrication of Ceramic Membrane Chromatography for Biologics Purification
title_fullStr Fabrication of Ceramic Membrane Chromatography for Biologics Purification
title_full_unstemmed Fabrication of Ceramic Membrane Chromatography for Biologics Purification
title_sort fabrication of ceramic membrane chromatography for biologics purification
publisher IIUM Press, International Islamic University Malaysia
series International Islamic University Malaysia Engineering Journal
issn 1511-788X
2289-7860
publishDate 2011-12-01
description Chromatography is one of the most important separation processes of choice for the recovery/purification of proteins and complex bio-structures. Fabrication of chromatographic membranes and their efficiency in the chromatography process has been the subject of many recent researches. In this study, a coin-like, 13 mm diameter and 3 mm thick, ceramic membrane was fabricated to be used as a chromatographic medium. The membrane is used to replace the conventional resin-based chromatography columns. Hydroxyapatite (HA) powder was used as a material for the membrane fabrication. In this project, a HA powder was produced using starch as pore creating agents. Characterization processes were done for the ceramic membrane using the suitable apparatuses. Three parameters of the fabrication process (starch wt %, compaction pressure and sintering temperature) were manipulated to optimize the performance of the membrane. The fabricated membrane was placed in a (FPLC) system to be tested for its performance as an adsorptive membrane. (IMAC) process was run by immobilizing Ni2+ ions at the membrane particles surfaces. NP protein of the (NDV) was used to test the membrane's ability to bind Histidine-tagged proteins. The optimum set of process parameters that yielded in the highest porosity and good chromatogram was determined to be 5 wt % starch, 3000 psi compaction pressure and 1100°C sintering temperature. ABSTRAK: Kromatografi merupakan satu daripada proses pengasingan yang penting yang dipilih untuk perolehan/penapisan protein dan biostruktur yang kompleks. Pemfabrikatan membran kromatografi dan kecekapannya dalam proses kromatografi merupakan fokus beberapa kajian terkini. Dalam kajian ini, membran seramik berbentuk duit syiling, berdiameter 13 mm dengan ketebalan 3 mm, direka untuk digunakan sebagai perantara kromatografi. Membran ini digunakan untuk menggantikan turus kromatografi berasaskan resin yang lazim. Serbuk hidroksiapatit (HA) digunakan sebagai bahan pemfabrikatan membran. Dalam projek ini, serbuk HA dihasilkan menggunakan kanji sebagai agen penghasilan liang. Proses pencirian dilakukan terhadap membran seramik menggunakan radas yang sesuai. Tiga parameter proses pemfabrikatan (peratusan berat kanji, tekanan padatan dan suhu pensinteran) dimanipulasikan untuk mendapatkan prestasi membran yang optima. Membran yang difabrikatkan diletakkan dalam sistem FPLC (Fast Protein Liquid Chromatography) untuk diuji prestasinya sebagai membran serap. Proses IMAC (Immobilized Metal Affinity Chromatography) dijalankan dengan memegunkan ion Ni2+ pada permukaan zarah membran. Nucleoprotein dari NDV (Newcastle disease virus) digunakan untuk menguji kebolehan membran terikat dengan protein yang dilabelkan dengan Hisditina. Set parameter proses yang optima yang menghasilkan keliangan tertinggi dan kromatogram yang baik ditentukan pada berat kanji 5 %, tekanan padatan 3000 psi dan suhu pensinteran 1100°C. KEYWORDS: Membrane Chromatography, Porous Ceramic Membrane, IMAC, Hydroxyapatite, Chromatography.
url http://journals.iium.edu.my/ejournal/index.php/iiumej/article/view/213
work_keys_str_mv AT maizirwanmel fabricationofceramicmembranechromatographyforbiologicspurification
AT fouadrhabdeen fabricationofceramicmembranechromatographyforbiologicspurification
AT andiissopyan fabricationofceramicmembranechromatographyforbiologicspurification
_version_ 1724630261699706880