Development of an MFL Coil Sensor for Testing Pipes in Extreme Temperature Conditions
This paper aims to design a coil sensor for corrosion monitoring of industrial pipes that could detect variations in thickness using the MFL (Magnetic Flux Leakage) technique. An MFL coil sensor is designed and tested with pipe sample thicknesses of 2, 4, 6, and 8 mm based on the magnetic field effe...