Application of the Electret in Alpha Radiation Sensor to Measure the Concentration of Radon in Selected Ambient Conditions

A novel electret sensor, made from a polytetrafluoroethylene (PTFE) foil, is proposed for monitoring of radon concentration in closed spaces. A triode air system was implemented to form the electret foil. In order to calibrate the electret sensor, the ionization chamber with the electret embedded at...

Full description

Bibliographic Details
Main Authors: Adam Gubanski, Jan Kupracz, Paweł Kostyla, Dominika Kaczorowska, Jerzy Wrobel
Format: Article
Language:English
Published: Hindawi Limited 2019-01-01
Series:Journal of Sensors
Online Access:http://dx.doi.org/10.1155/2019/1705481
id doaj-95bb08dc099d4116b47c4fb0c3dfc52b
record_format Article
spelling doaj-95bb08dc099d4116b47c4fb0c3dfc52b2020-11-24T21:50:32ZengHindawi LimitedJournal of Sensors1687-725X1687-72682019-01-01201910.1155/2019/17054811705481Application of the Electret in Alpha Radiation Sensor to Measure the Concentration of Radon in Selected Ambient ConditionsAdam Gubanski0Jan Kupracz1Paweł Kostyla2Dominika Kaczorowska3Jerzy Wrobel4Faculty of Electrical Engineering, Wroclaw University of Science and Technology, Wybrzeze Wyspianskiego 27, Wroclaw 50-370, PolandFaculty of Electrical Engineering, Wroclaw University of Science and Technology, Wybrzeze Wyspianskiego 27, Wroclaw 50-370, PolandFaculty of Electrical Engineering, Wroclaw University of Science and Technology, Wybrzeze Wyspianskiego 27, Wroclaw 50-370, PolandFaculty of Electrical Engineering, Wroclaw University of Science and Technology, Wybrzeze Wyspianskiego 27, Wroclaw 50-370, PolandDepartment of Physics and Astronomy, University of Missouri-Kansas City, 5110 Rockhill Road, Kansas City, MO 64111, USAA novel electret sensor, made from a polytetrafluoroethylene (PTFE) foil, is proposed for monitoring of radon concentration in closed spaces. A triode air system was implemented to form the electret foil. In order to calibrate the electret sensor, the ionization chamber with the electret embedded at its bottom, was placed in an emanation chamber containing radon of known concentration. The change in the effective charge density of the electret resulting from the interaction of the electret sensor with ionizing radiation, make it possible to determine the degree of its response to the radon concentration in the examined environment. The electric charge of the electret sensor was evaluated at the beginning and at the end of the concentration measurement using a field chopper. The measurement of the value of the electric field between the electret and the reference electrode directly corresponds to the effective surface charge density of the electret. The measuring system was calibrated in values of the electret equivalent voltage of Uz. In order to assess the electret properties, both the thermostimulated charge relaxation (TSQ) method and the thermostimulated discharge current (TSDC) method were used to evaluate corresponding parameters. These investigations led to the optimization of the electret formation process for the maximum sensitivity to the effects of alpha particles resulting from radon radioactive decay.http://dx.doi.org/10.1155/2019/1705481
collection DOAJ
language English
format Article
sources DOAJ
author Adam Gubanski
Jan Kupracz
Paweł Kostyla
Dominika Kaczorowska
Jerzy Wrobel
spellingShingle Adam Gubanski
Jan Kupracz
Paweł Kostyla
Dominika Kaczorowska
Jerzy Wrobel
Application of the Electret in Alpha Radiation Sensor to Measure the Concentration of Radon in Selected Ambient Conditions
Journal of Sensors
author_facet Adam Gubanski
Jan Kupracz
Paweł Kostyla
Dominika Kaczorowska
Jerzy Wrobel
author_sort Adam Gubanski
title Application of the Electret in Alpha Radiation Sensor to Measure the Concentration of Radon in Selected Ambient Conditions
title_short Application of the Electret in Alpha Radiation Sensor to Measure the Concentration of Radon in Selected Ambient Conditions
title_full Application of the Electret in Alpha Radiation Sensor to Measure the Concentration of Radon in Selected Ambient Conditions
title_fullStr Application of the Electret in Alpha Radiation Sensor to Measure the Concentration of Radon in Selected Ambient Conditions
title_full_unstemmed Application of the Electret in Alpha Radiation Sensor to Measure the Concentration of Radon in Selected Ambient Conditions
title_sort application of the electret in alpha radiation sensor to measure the concentration of radon in selected ambient conditions
publisher Hindawi Limited
series Journal of Sensors
issn 1687-725X
1687-7268
publishDate 2019-01-01
description A novel electret sensor, made from a polytetrafluoroethylene (PTFE) foil, is proposed for monitoring of radon concentration in closed spaces. A triode air system was implemented to form the electret foil. In order to calibrate the electret sensor, the ionization chamber with the electret embedded at its bottom, was placed in an emanation chamber containing radon of known concentration. The change in the effective charge density of the electret resulting from the interaction of the electret sensor with ionizing radiation, make it possible to determine the degree of its response to the radon concentration in the examined environment. The electric charge of the electret sensor was evaluated at the beginning and at the end of the concentration measurement using a field chopper. The measurement of the value of the electric field between the electret and the reference electrode directly corresponds to the effective surface charge density of the electret. The measuring system was calibrated in values of the electret equivalent voltage of Uz. In order to assess the electret properties, both the thermostimulated charge relaxation (TSQ) method and the thermostimulated discharge current (TSDC) method were used to evaluate corresponding parameters. These investigations led to the optimization of the electret formation process for the maximum sensitivity to the effects of alpha particles resulting from radon radioactive decay.
url http://dx.doi.org/10.1155/2019/1705481
work_keys_str_mv AT adamgubanski applicationoftheelectretinalpharadiationsensortomeasuretheconcentrationofradoninselectedambientconditions
AT jankupracz applicationoftheelectretinalpharadiationsensortomeasuretheconcentrationofradoninselectedambientconditions
AT pawełkostyla applicationoftheelectretinalpharadiationsensortomeasuretheconcentrationofradoninselectedambientconditions
AT dominikakaczorowska applicationoftheelectretinalpharadiationsensortomeasuretheconcentrationofradoninselectedambientconditions
AT jerzywrobel applicationoftheelectretinalpharadiationsensortomeasuretheconcentrationofradoninselectedambientconditions
_version_ 1725883378145689600