Application of the Electret in Alpha Radiation Sensor to Measure the Concentration of Radon in Selected Ambient Conditions
A novel electret sensor, made from a polytetrafluoroethylene (PTFE) foil, is proposed for monitoring of radon concentration in closed spaces. A triode air system was implemented to form the electret foil. In order to calibrate the electret sensor, the ionization chamber with the electret embedded at...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Hindawi Limited
2019-01-01
|
Series: | Journal of Sensors |
Online Access: | http://dx.doi.org/10.1155/2019/1705481 |
id |
doaj-95bb08dc099d4116b47c4fb0c3dfc52b |
---|---|
record_format |
Article |
spelling |
doaj-95bb08dc099d4116b47c4fb0c3dfc52b2020-11-24T21:50:32ZengHindawi LimitedJournal of Sensors1687-725X1687-72682019-01-01201910.1155/2019/17054811705481Application of the Electret in Alpha Radiation Sensor to Measure the Concentration of Radon in Selected Ambient ConditionsAdam Gubanski0Jan Kupracz1Paweł Kostyla2Dominika Kaczorowska3Jerzy Wrobel4Faculty of Electrical Engineering, Wroclaw University of Science and Technology, Wybrzeze Wyspianskiego 27, Wroclaw 50-370, PolandFaculty of Electrical Engineering, Wroclaw University of Science and Technology, Wybrzeze Wyspianskiego 27, Wroclaw 50-370, PolandFaculty of Electrical Engineering, Wroclaw University of Science and Technology, Wybrzeze Wyspianskiego 27, Wroclaw 50-370, PolandFaculty of Electrical Engineering, Wroclaw University of Science and Technology, Wybrzeze Wyspianskiego 27, Wroclaw 50-370, PolandDepartment of Physics and Astronomy, University of Missouri-Kansas City, 5110 Rockhill Road, Kansas City, MO 64111, USAA novel electret sensor, made from a polytetrafluoroethylene (PTFE) foil, is proposed for monitoring of radon concentration in closed spaces. A triode air system was implemented to form the electret foil. In order to calibrate the electret sensor, the ionization chamber with the electret embedded at its bottom, was placed in an emanation chamber containing radon of known concentration. The change in the effective charge density of the electret resulting from the interaction of the electret sensor with ionizing radiation, make it possible to determine the degree of its response to the radon concentration in the examined environment. The electric charge of the electret sensor was evaluated at the beginning and at the end of the concentration measurement using a field chopper. The measurement of the value of the electric field between the electret and the reference electrode directly corresponds to the effective surface charge density of the electret. The measuring system was calibrated in values of the electret equivalent voltage of Uz. In order to assess the electret properties, both the thermostimulated charge relaxation (TSQ) method and the thermostimulated discharge current (TSDC) method were used to evaluate corresponding parameters. These investigations led to the optimization of the electret formation process for the maximum sensitivity to the effects of alpha particles resulting from radon radioactive decay.http://dx.doi.org/10.1155/2019/1705481 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Adam Gubanski Jan Kupracz Paweł Kostyla Dominika Kaczorowska Jerzy Wrobel |
spellingShingle |
Adam Gubanski Jan Kupracz Paweł Kostyla Dominika Kaczorowska Jerzy Wrobel Application of the Electret in Alpha Radiation Sensor to Measure the Concentration of Radon in Selected Ambient Conditions Journal of Sensors |
author_facet |
Adam Gubanski Jan Kupracz Paweł Kostyla Dominika Kaczorowska Jerzy Wrobel |
author_sort |
Adam Gubanski |
title |
Application of the Electret in Alpha Radiation Sensor to Measure the Concentration of Radon in Selected Ambient Conditions |
title_short |
Application of the Electret in Alpha Radiation Sensor to Measure the Concentration of Radon in Selected Ambient Conditions |
title_full |
Application of the Electret in Alpha Radiation Sensor to Measure the Concentration of Radon in Selected Ambient Conditions |
title_fullStr |
Application of the Electret in Alpha Radiation Sensor to Measure the Concentration of Radon in Selected Ambient Conditions |
title_full_unstemmed |
Application of the Electret in Alpha Radiation Sensor to Measure the Concentration of Radon in Selected Ambient Conditions |
title_sort |
application of the electret in alpha radiation sensor to measure the concentration of radon in selected ambient conditions |
publisher |
Hindawi Limited |
series |
Journal of Sensors |
issn |
1687-725X 1687-7268 |
publishDate |
2019-01-01 |
description |
A novel electret sensor, made from a polytetrafluoroethylene (PTFE) foil, is proposed for monitoring of radon concentration in closed spaces. A triode air system was implemented to form the electret foil. In order to calibrate the electret sensor, the ionization chamber with the electret embedded at its bottom, was placed in an emanation chamber containing radon of known concentration. The change in the effective charge density of the electret resulting from the interaction of the electret sensor with ionizing radiation, make it possible to determine the degree of its response to the radon concentration in the examined environment. The electric charge of the electret sensor was evaluated at the beginning and at the end of the concentration measurement using a field chopper. The measurement of the value of the electric field between the electret and the reference electrode directly corresponds to the effective surface charge density of the electret. The measuring system was calibrated in values of the electret equivalent voltage of Uz. In order to assess the electret properties, both the thermostimulated charge relaxation (TSQ) method and the thermostimulated discharge current (TSDC) method were used to evaluate corresponding parameters. These investigations led to the optimization of the electret formation process for the maximum sensitivity to the effects of alpha particles resulting from radon radioactive decay. |
url |
http://dx.doi.org/10.1155/2019/1705481 |
work_keys_str_mv |
AT adamgubanski applicationoftheelectretinalpharadiationsensortomeasuretheconcentrationofradoninselectedambientconditions AT jankupracz applicationoftheelectretinalpharadiationsensortomeasuretheconcentrationofradoninselectedambientconditions AT pawełkostyla applicationoftheelectretinalpharadiationsensortomeasuretheconcentrationofradoninselectedambientconditions AT dominikakaczorowska applicationoftheelectretinalpharadiationsensortomeasuretheconcentrationofradoninselectedambientconditions AT jerzywrobel applicationoftheelectretinalpharadiationsensortomeasuretheconcentrationofradoninselectedambientconditions |
_version_ |
1725883378145689600 |