New bipolar tissue ligator combines constant tissue compression and temperature guidance: histologic study and implications for treatment of hemorrhoids

Gregory Piskun,1 Robert Tucker21Department of Surgery, New York Methodist Hospital, Brooklyn, NY, USA; 2Department of Pathology, University of Iowa College of Medicine, Iowa City, IA, USABackground: Several minimally invasive technologies are available to treat common soft tissue lesions including s...

Full description

Bibliographic Details
Main Authors: Piskun G, Tucker R
Format: Article
Language:English
Published: Dove Medical Press 2012-10-01
Series:Medical Devices : Evidence and Research
Online Access:http://www.dovepress.com/new-bipolar-tissue-ligator-combines-constant-tissue-compression-and-te-a11275
id doaj-9584ea24e86b41079f11d15a951798a8
record_format Article
spelling doaj-9584ea24e86b41079f11d15a951798a82020-11-24T23:47:56ZengDove Medical PressMedical Devices : Evidence and Research1179-14702012-10-012012default8996New bipolar tissue ligator combines constant tissue compression and temperature guidance: histologic study and implications for treatment of hemorrhoidsPiskun GTucker RGregory Piskun,1 Robert Tucker21Department of Surgery, New York Methodist Hospital, Brooklyn, NY, USA; 2Department of Pathology, University of Iowa College of Medicine, Iowa City, IA, USABackground: Several minimally invasive technologies are available to treat common soft tissue lesions including symptomatic hemorrhoids. The use of energy to deliver heat and coagulate target lesions is commonly practiced. This study compares the histologic effects produced on intestinal tissues by two energy-based systems which employ different approaches of heat delivery.Methods: Two heat delivery systems were evaluated in vivo in a single porcine subject: infrared coagulator and bipolar tissue ligator utilizing constant tissue compression and temperature guidance. Eighteen treatment sites divided into three groups of six were assessed. Treatment site temperature was measured and the effects of thermal treatment in the mucosa, submucosa, submucosal vessels, and muscularis layer were scored. Lateral thermal spread beyond the energy application site was also assessed.Results: Treatment site temperatures were much lower in the bipolar ligator group than in the infrared coagulator group. The mucosal and submucosal tissue changes observed in tissues treated with infrared energy and bipolar energy at 55°C were similar. Both the mucosal and submucosal tissue changes with bipolar energy at 50°C were significantly less.Conclusion: Both devices achieved similar histologic results. However, the unique design of the bipolar ligator, which allows consistent capture, constant compression, and temperature monitoring of target tissue, accomplished the desired histologic changes with less muscular damage at much lower temperatures than the infrared coagulator. The use of bipolar ligation could offer clinical advantages such as reduced patient pain and a minimized chance of heat-related collateral tissue damage.Keywords: bipolar ligator, internal hemorrhoids, tissue manipulation, ligationhttp://www.dovepress.com/new-bipolar-tissue-ligator-combines-constant-tissue-compression-and-te-a11275
collection DOAJ
language English
format Article
sources DOAJ
author Piskun G
Tucker R
spellingShingle Piskun G
Tucker R
New bipolar tissue ligator combines constant tissue compression and temperature guidance: histologic study and implications for treatment of hemorrhoids
Medical Devices : Evidence and Research
author_facet Piskun G
Tucker R
author_sort Piskun G
title New bipolar tissue ligator combines constant tissue compression and temperature guidance: histologic study and implications for treatment of hemorrhoids
title_short New bipolar tissue ligator combines constant tissue compression and temperature guidance: histologic study and implications for treatment of hemorrhoids
title_full New bipolar tissue ligator combines constant tissue compression and temperature guidance: histologic study and implications for treatment of hemorrhoids
title_fullStr New bipolar tissue ligator combines constant tissue compression and temperature guidance: histologic study and implications for treatment of hemorrhoids
title_full_unstemmed New bipolar tissue ligator combines constant tissue compression and temperature guidance: histologic study and implications for treatment of hemorrhoids
title_sort new bipolar tissue ligator combines constant tissue compression and temperature guidance: histologic study and implications for treatment of hemorrhoids
publisher Dove Medical Press
series Medical Devices : Evidence and Research
issn 1179-1470
publishDate 2012-10-01
description Gregory Piskun,1 Robert Tucker21Department of Surgery, New York Methodist Hospital, Brooklyn, NY, USA; 2Department of Pathology, University of Iowa College of Medicine, Iowa City, IA, USABackground: Several minimally invasive technologies are available to treat common soft tissue lesions including symptomatic hemorrhoids. The use of energy to deliver heat and coagulate target lesions is commonly practiced. This study compares the histologic effects produced on intestinal tissues by two energy-based systems which employ different approaches of heat delivery.Methods: Two heat delivery systems were evaluated in vivo in a single porcine subject: infrared coagulator and bipolar tissue ligator utilizing constant tissue compression and temperature guidance. Eighteen treatment sites divided into three groups of six were assessed. Treatment site temperature was measured and the effects of thermal treatment in the mucosa, submucosa, submucosal vessels, and muscularis layer were scored. Lateral thermal spread beyond the energy application site was also assessed.Results: Treatment site temperatures were much lower in the bipolar ligator group than in the infrared coagulator group. The mucosal and submucosal tissue changes observed in tissues treated with infrared energy and bipolar energy at 55°C were similar. Both the mucosal and submucosal tissue changes with bipolar energy at 50°C were significantly less.Conclusion: Both devices achieved similar histologic results. However, the unique design of the bipolar ligator, which allows consistent capture, constant compression, and temperature monitoring of target tissue, accomplished the desired histologic changes with less muscular damage at much lower temperatures than the infrared coagulator. The use of bipolar ligation could offer clinical advantages such as reduced patient pain and a minimized chance of heat-related collateral tissue damage.Keywords: bipolar ligator, internal hemorrhoids, tissue manipulation, ligation
url http://www.dovepress.com/new-bipolar-tissue-ligator-combines-constant-tissue-compression-and-te-a11275
work_keys_str_mv AT piskung newbipolartissueligatorcombinesconstanttissuecompressionandtemperatureguidancehistologicstudyandimplicationsfortreatmentofhemorrhoids
AT tuckerr newbipolartissueligatorcombinesconstanttissuecompressionandtemperatureguidancehistologicstudyandimplicationsfortreatmentofhemorrhoids
_version_ 1725488030989418496