New bipolar tissue ligator combines constant tissue compression and temperature guidance: histologic study and implications for treatment of hemorrhoids
Gregory Piskun,1 Robert Tucker21Department of Surgery, New York Methodist Hospital, Brooklyn, NY, USA; 2Department of Pathology, University of Iowa College of Medicine, Iowa City, IA, USABackground: Several minimally invasive technologies are available to treat common soft tissue lesions including s...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Dove Medical Press
2012-10-01
|
Series: | Medical Devices : Evidence and Research |
Online Access: | http://www.dovepress.com/new-bipolar-tissue-ligator-combines-constant-tissue-compression-and-te-a11275 |
id |
doaj-9584ea24e86b41079f11d15a951798a8 |
---|---|
record_format |
Article |
spelling |
doaj-9584ea24e86b41079f11d15a951798a82020-11-24T23:47:56ZengDove Medical PressMedical Devices : Evidence and Research1179-14702012-10-012012default8996New bipolar tissue ligator combines constant tissue compression and temperature guidance: histologic study and implications for treatment of hemorrhoidsPiskun GTucker RGregory Piskun,1 Robert Tucker21Department of Surgery, New York Methodist Hospital, Brooklyn, NY, USA; 2Department of Pathology, University of Iowa College of Medicine, Iowa City, IA, USABackground: Several minimally invasive technologies are available to treat common soft tissue lesions including symptomatic hemorrhoids. The use of energy to deliver heat and coagulate target lesions is commonly practiced. This study compares the histologic effects produced on intestinal tissues by two energy-based systems which employ different approaches of heat delivery.Methods: Two heat delivery systems were evaluated in vivo in a single porcine subject: infrared coagulator and bipolar tissue ligator utilizing constant tissue compression and temperature guidance. Eighteen treatment sites divided into three groups of six were assessed. Treatment site temperature was measured and the effects of thermal treatment in the mucosa, submucosa, submucosal vessels, and muscularis layer were scored. Lateral thermal spread beyond the energy application site was also assessed.Results: Treatment site temperatures were much lower in the bipolar ligator group than in the infrared coagulator group. The mucosal and submucosal tissue changes observed in tissues treated with infrared energy and bipolar energy at 55°C were similar. Both the mucosal and submucosal tissue changes with bipolar energy at 50°C were significantly less.Conclusion: Both devices achieved similar histologic results. However, the unique design of the bipolar ligator, which allows consistent capture, constant compression, and temperature monitoring of target tissue, accomplished the desired histologic changes with less muscular damage at much lower temperatures than the infrared coagulator. The use of bipolar ligation could offer clinical advantages such as reduced patient pain and a minimized chance of heat-related collateral tissue damage.Keywords: bipolar ligator, internal hemorrhoids, tissue manipulation, ligationhttp://www.dovepress.com/new-bipolar-tissue-ligator-combines-constant-tissue-compression-and-te-a11275 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Piskun G Tucker R |
spellingShingle |
Piskun G Tucker R New bipolar tissue ligator combines constant tissue compression and temperature guidance: histologic study and implications for treatment of hemorrhoids Medical Devices : Evidence and Research |
author_facet |
Piskun G Tucker R |
author_sort |
Piskun G |
title |
New bipolar tissue ligator combines constant tissue compression and temperature guidance: histologic study and implications for treatment of hemorrhoids |
title_short |
New bipolar tissue ligator combines constant tissue compression and temperature guidance: histologic study and implications for treatment of hemorrhoids |
title_full |
New bipolar tissue ligator combines constant tissue compression and temperature guidance: histologic study and implications for treatment of hemorrhoids |
title_fullStr |
New bipolar tissue ligator combines constant tissue compression and temperature guidance: histologic study and implications for treatment of hemorrhoids |
title_full_unstemmed |
New bipolar tissue ligator combines constant tissue compression and temperature guidance: histologic study and implications for treatment of hemorrhoids |
title_sort |
new bipolar tissue ligator combines constant tissue compression and temperature guidance: histologic study and implications for treatment of hemorrhoids |
publisher |
Dove Medical Press |
series |
Medical Devices : Evidence and Research |
issn |
1179-1470 |
publishDate |
2012-10-01 |
description |
Gregory Piskun,1 Robert Tucker21Department of Surgery, New York Methodist Hospital, Brooklyn, NY, USA; 2Department of Pathology, University of Iowa College of Medicine, Iowa City, IA, USABackground: Several minimally invasive technologies are available to treat common soft tissue lesions including symptomatic hemorrhoids. The use of energy to deliver heat and coagulate target lesions is commonly practiced. This study compares the histologic effects produced on intestinal tissues by two energy-based systems which employ different approaches of heat delivery.Methods: Two heat delivery systems were evaluated in vivo in a single porcine subject: infrared coagulator and bipolar tissue ligator utilizing constant tissue compression and temperature guidance. Eighteen treatment sites divided into three groups of six were assessed. Treatment site temperature was measured and the effects of thermal treatment in the mucosa, submucosa, submucosal vessels, and muscularis layer were scored. Lateral thermal spread beyond the energy application site was also assessed.Results: Treatment site temperatures were much lower in the bipolar ligator group than in the infrared coagulator group. The mucosal and submucosal tissue changes observed in tissues treated with infrared energy and bipolar energy at 55°C were similar. Both the mucosal and submucosal tissue changes with bipolar energy at 50°C were significantly less.Conclusion: Both devices achieved similar histologic results. However, the unique design of the bipolar ligator, which allows consistent capture, constant compression, and temperature monitoring of target tissue, accomplished the desired histologic changes with less muscular damage at much lower temperatures than the infrared coagulator. The use of bipolar ligation could offer clinical advantages such as reduced patient pain and a minimized chance of heat-related collateral tissue damage.Keywords: bipolar ligator, internal hemorrhoids, tissue manipulation, ligation |
url |
http://www.dovepress.com/new-bipolar-tissue-ligator-combines-constant-tissue-compression-and-te-a11275 |
work_keys_str_mv |
AT piskung newbipolartissueligatorcombinesconstanttissuecompressionandtemperatureguidancehistologicstudyandimplicationsfortreatmentofhemorrhoids AT tuckerr newbipolartissueligatorcombinesconstanttissuecompressionandtemperatureguidancehistologicstudyandimplicationsfortreatmentofhemorrhoids |
_version_ |
1725488030989418496 |