Analysis of mode of surge arrester in the presence of nonsinusoidal voltage

In the article it is considered the work of nonlinear surge arrester in quasi-stationary modes and found that similar work almost impossible. Many power engineering specialists believe that NSA works so as the valve gap. This claim is false because NSA is connected directly to the network through a...

Full description

Bibliographic Details
Main Author: Сергій Юрійович Шевченко
Format: Article
Language:English
Published: PC Technology Center 2015-07-01
Series:Tehnologìčnij Audit ta Rezervi Virobnictva
Subjects:
Online Access:http://journals.uran.ua/tarp/article/view/46960
id doaj-92f1f63774d14a739fb6ef86e951d748
record_format Article
spelling doaj-92f1f63774d14a739fb6ef86e951d7482020-11-25T03:34:57ZengPC Technology CenterTehnologìčnij Audit ta Rezervi Virobnictva2226-37802312-83722015-07-0141(24)151910.15587/2312-8372.2015.4696046960Analysis of mode of surge arrester in the presence of nonsinusoidal voltageСергій Юрійович Шевченко0National Technical University "Kharkiv Polytechnic Institute", 21, Frunze str., 61002, KharkivIn the article it is considered the work of nonlinear surge arrester in quasi-stationary modes and found that similar work almost impossible. Many power engineering specialists believe that NSA works so as the valve gap. This claim is false because NSA is connected directly to the network through a gap the spark gap. Therefore NSA is constantly under the influence of the working voltage, which causes additional requirements for its parameters when a quasi-stationary over the network. The calculations of the energy dissipation of NSA under the action as part of which there are higher harmonics allow to conclude that in accordance voltage requirements of GOST on energy quality. NSA is working properly supporting thermal balance. However, NSA violation of thermal balance can occur when working in networks with a high content of harmonic oscillations, leading to its failure. Calculations are made on the basis of current-voltage characteristics of NSA, which allows determining the value of currents in the presence of voltage in the network containing harmonic oscillations.http://journals.uran.ua/tarp/article/view/46960nonlinear surge arrestercurrent-voltage characteristicsthermal conditionharmonic oscillations
collection DOAJ
language English
format Article
sources DOAJ
author Сергій Юрійович Шевченко
spellingShingle Сергій Юрійович Шевченко
Analysis of mode of surge arrester in the presence of nonsinusoidal voltage
Tehnologìčnij Audit ta Rezervi Virobnictva
nonlinear surge arrester
current-voltage characteristics
thermal condition
harmonic oscillations
author_facet Сергій Юрійович Шевченко
author_sort Сергій Юрійович Шевченко
title Analysis of mode of surge arrester in the presence of nonsinusoidal voltage
title_short Analysis of mode of surge arrester in the presence of nonsinusoidal voltage
title_full Analysis of mode of surge arrester in the presence of nonsinusoidal voltage
title_fullStr Analysis of mode of surge arrester in the presence of nonsinusoidal voltage
title_full_unstemmed Analysis of mode of surge arrester in the presence of nonsinusoidal voltage
title_sort analysis of mode of surge arrester in the presence of nonsinusoidal voltage
publisher PC Technology Center
series Tehnologìčnij Audit ta Rezervi Virobnictva
issn 2226-3780
2312-8372
publishDate 2015-07-01
description In the article it is considered the work of nonlinear surge arrester in quasi-stationary modes and found that similar work almost impossible. Many power engineering specialists believe that NSA works so as the valve gap. This claim is false because NSA is connected directly to the network through a gap the spark gap. Therefore NSA is constantly under the influence of the working voltage, which causes additional requirements for its parameters when a quasi-stationary over the network. The calculations of the energy dissipation of NSA under the action as part of which there are higher harmonics allow to conclude that in accordance voltage requirements of GOST on energy quality. NSA is working properly supporting thermal balance. However, NSA violation of thermal balance can occur when working in networks with a high content of harmonic oscillations, leading to its failure. Calculations are made on the basis of current-voltage characteristics of NSA, which allows determining the value of currents in the presence of voltage in the network containing harmonic oscillations.
topic nonlinear surge arrester
current-voltage characteristics
thermal condition
harmonic oscillations