Intraoperative near-infrared spectroscopy for pedicled perforator flaps: a possible tool for the early detection of vascular issues

Background Pedicled perforator flaps can present postoperative complications similar to those encountered in free flap surgery. Beyond a clinical evaluation, there is still no reliable technical aid for the early prediction of vascular issues. The aim of this study was to assess the support of near-...

Full description

Bibliographic Details
Main Authors: Andrea Marchesi, Pietro Garieri, Francesco Amendola, Stefano Marcelli, Luca Vaienti
Format: Article
Language:English
Published: Korean Society of Plastic and Reconstructive Surgeons 2021-07-01
Series:Archives of Plastic Surgery
Subjects:
Online Access:http://www.e-aps.org/upload/pdf/aps-2019-00311.pdf
id doaj-92da5a1bd8654c068c6bc40282434a91
record_format Article
spelling doaj-92da5a1bd8654c068c6bc40282434a912021-07-26T00:26:26ZengKorean Society of Plastic and Reconstructive SurgeonsArchives of Plastic Surgery2234-61632234-61712021-07-0148445746110.5999/aps.2019.003113882Intraoperative near-infrared spectroscopy for pedicled perforator flaps: a possible tool for the early detection of vascular issuesAndrea Marchesi0Pietro Garieri1Francesco Amendola2Stefano Marcelli3Luca Vaienti4 Department of Plastic Surgery, Hand Surgery and Reconstructive Microsurgery, Ospedale San Gerardo, Monza, Italy Department of Plastic Surgery, Hand Surgery and Reconstructive Microsurgery, Ospedale San Gerardo, Monza, Italy Department of Plastic Surgery, Hand Surgery and Reconstructive Microsurgery, Ospedale San Gerardo, Monza, Italy Department of Plastic Surgery, Hand Surgery and Reconstructive Microsurgery, Ospedale San Gerardo, Monza, Italy Department of Plastic Surgery, Hand Surgery and Reconstructive Microsurgery, Ospedale San Gerardo, Monza, ItalyBackground Pedicled perforator flaps can present postoperative complications similar to those encountered in free flap surgery. Beyond a clinical evaluation, there is still no reliable technical aid for the early prediction of vascular issues. The aim of this study was to assess the support of near-infrared spectroscopy technology as an intraoperative tool to anticipate postsurgical flap ischemia. Methods We prospectively enrolled 13 consecutive patients who were referred to our hospital from March 2017 to July 2018 and required a reconstructive procedure with a pedicled fasciocutaneous perforator flap. We measured flap peripheral capillary oxygen saturation (SpO2) in each patient with a Somanetics INVOS 5100C Cerebral/Somatic Oximeter (Medtronic), both before and after transposition. Patient demographics, operative data, and complications were then recorded during the following 6 months. We analyzed the data using the Wilcoxon signed-rank test and linear regression. Results The mean flap SpO2 before and after transposition was 92%±3% and 78%±19%, respectively. The mean change in SpO2 was 14%±17%, with a range of 0% to 55%. The change in saturation and mean saturation ratio were significantly different between patients with and without postoperative flap necrosis. Conclusions An immediate quantitative analysis of flap peripheral capillary SpO2 after transposition has never before been described. In our experience, an intraoperative drop in SpO2 equal to or greater than 15%–20% predicted vascular complications in pedicled perforator flaps. Conversely, flap size and rotation angle were not correlated with the risk of flap necrosis.http://www.e-aps.org/upload/pdf/aps-2019-00311.pdfperforator flapoximetrymonitoringsurgical flappostoperative complications
collection DOAJ
language English
format Article
sources DOAJ
author Andrea Marchesi
Pietro Garieri
Francesco Amendola
Stefano Marcelli
Luca Vaienti
spellingShingle Andrea Marchesi
Pietro Garieri
Francesco Amendola
Stefano Marcelli
Luca Vaienti
Intraoperative near-infrared spectroscopy for pedicled perforator flaps: a possible tool for the early detection of vascular issues
Archives of Plastic Surgery
perforator flap
oximetry
monitoring
surgical flap
postoperative complications
author_facet Andrea Marchesi
Pietro Garieri
Francesco Amendola
Stefano Marcelli
Luca Vaienti
author_sort Andrea Marchesi
title Intraoperative near-infrared spectroscopy for pedicled perforator flaps: a possible tool for the early detection of vascular issues
title_short Intraoperative near-infrared spectroscopy for pedicled perforator flaps: a possible tool for the early detection of vascular issues
title_full Intraoperative near-infrared spectroscopy for pedicled perforator flaps: a possible tool for the early detection of vascular issues
title_fullStr Intraoperative near-infrared spectroscopy for pedicled perforator flaps: a possible tool for the early detection of vascular issues
title_full_unstemmed Intraoperative near-infrared spectroscopy for pedicled perforator flaps: a possible tool for the early detection of vascular issues
title_sort intraoperative near-infrared spectroscopy for pedicled perforator flaps: a possible tool for the early detection of vascular issues
publisher Korean Society of Plastic and Reconstructive Surgeons
series Archives of Plastic Surgery
issn 2234-6163
2234-6171
publishDate 2021-07-01
description Background Pedicled perforator flaps can present postoperative complications similar to those encountered in free flap surgery. Beyond a clinical evaluation, there is still no reliable technical aid for the early prediction of vascular issues. The aim of this study was to assess the support of near-infrared spectroscopy technology as an intraoperative tool to anticipate postsurgical flap ischemia. Methods We prospectively enrolled 13 consecutive patients who were referred to our hospital from March 2017 to July 2018 and required a reconstructive procedure with a pedicled fasciocutaneous perforator flap. We measured flap peripheral capillary oxygen saturation (SpO2) in each patient with a Somanetics INVOS 5100C Cerebral/Somatic Oximeter (Medtronic), both before and after transposition. Patient demographics, operative data, and complications were then recorded during the following 6 months. We analyzed the data using the Wilcoxon signed-rank test and linear regression. Results The mean flap SpO2 before and after transposition was 92%±3% and 78%±19%, respectively. The mean change in SpO2 was 14%±17%, with a range of 0% to 55%. The change in saturation and mean saturation ratio were significantly different between patients with and without postoperative flap necrosis. Conclusions An immediate quantitative analysis of flap peripheral capillary SpO2 after transposition has never before been described. In our experience, an intraoperative drop in SpO2 equal to or greater than 15%–20% predicted vascular complications in pedicled perforator flaps. Conversely, flap size and rotation angle were not correlated with the risk of flap necrosis.
topic perforator flap
oximetry
monitoring
surgical flap
postoperative complications
url http://www.e-aps.org/upload/pdf/aps-2019-00311.pdf
work_keys_str_mv AT andreamarchesi intraoperativenearinfraredspectroscopyforpedicledperforatorflapsapossibletoolfortheearlydetectionofvascularissues
AT pietrogarieri intraoperativenearinfraredspectroscopyforpedicledperforatorflapsapossibletoolfortheearlydetectionofvascularissues
AT francescoamendola intraoperativenearinfraredspectroscopyforpedicledperforatorflapsapossibletoolfortheearlydetectionofvascularissues
AT stefanomarcelli intraoperativenearinfraredspectroscopyforpedicledperforatorflapsapossibletoolfortheearlydetectionofvascularissues
AT lucavaienti intraoperativenearinfraredspectroscopyforpedicledperforatorflapsapossibletoolfortheearlydetectionofvascularissues
_version_ 1721282551411113984