Dual 2-Hydroxypropyl-β-Cyclodextrin and 5,10,15,20-Tetrakis (4-Hydroxyphenyl) Porphyrin System as a Novel Chiral-Achiral Selector Complex for Enantioseparation of Aminoalkanol Derivatives with Anticancer Activity in Capillary Electrophoresis
In this study, a complex consisting of 2-hydroxypropyl-β-cyclodextrin and 5,10,15,20-tetrakis (4-hydroxyphenyl) porphyrin, (named dual chiral-achiral selector complex) was used for the determination of two novel potential anticancer agents of (I) and (II) aminoalkanol derivatives. This work aimed at...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2021-02-01
|
Series: | Molecules |
Subjects: | |
Online Access: | https://www.mdpi.com/1420-3049/26/4/993 |
id |
doaj-91edf5fa61e34527947f9d0ff4d1117f |
---|---|
record_format |
Article |
spelling |
doaj-91edf5fa61e34527947f9d0ff4d1117f2021-02-14T00:01:38ZengMDPI AGMolecules1420-30492021-02-012699399310.3390/molecules26040993Dual 2-Hydroxypropyl-β-Cyclodextrin and 5,10,15,20-Tetrakis (4-Hydroxyphenyl) Porphyrin System as a Novel Chiral-Achiral Selector Complex for Enantioseparation of Aminoalkanol Derivatives with Anticancer Activity in Capillary ElectrophoresisBłażej Grodner0Mariola Napiórkowska1Chair and Department of Biochemistry and Pharmacogenomics, Medical University of Warsaw, 1 Banacha Str., 02-097 Warsaw, PolandChair and Department of Biochemistry, Medical University of Warsaw, 1 Banacha Str., 02-097 Warsaw, PolandIn this study, a complex consisting of 2-hydroxypropyl-β-cyclodextrin and 5,10,15,20-tetrakis (4-hydroxyphenyl) porphyrin, (named dual chiral-achiral selector complex) was used for the determination of two novel potential anticancer agents of (I) and (II) aminoalkanol derivatives. This work aimed at developing an effective method that can be utilized for the determination of I (S), I (R), and II (S) and II (R) enantiomers of (I) and (II) compounds through the use of a dual chiral-achiral selector complex consisting of hydroxypropyl-β-cyclodextrin and 5,10,15,20-tetrakis (4-hydroxyphenyl) porphyrin system by applying capillary electrophoresis. This combination proved to be beneficial in achieving high separation selectivity due to the combined effects of different modes of chiral discrimination. The enantiomers of (I) and (II) compounds were separated within a very short time of 3.6–7.2 min, in pH 2.5 phosphate buffer containing 2-hydroxypropyl-β-cyclodextrin and 5,10,15,20-tetrakis (4-hydroxyphenyl) porphyrin system at a concentration of 5 and 10 mM, respectively, at 25 °C and +10 kV. The detection wavelength of the detector was set at 200 nm. The LOD for I (S), I (R), II (S), and II (R) was 65.2, 65.6, 65.1, and 65.7 ng/mL, respectively. LOQ for I (S), I (R), II (S), and II (R) was 216.5, 217.8, 217.1, and 218.1 ng/mL, respectively. Recovery was 94.9–99.9%. The repeatability and reproducibility of the method based on the values of the migration time, and the area under the peak was 0.3–2.9% RSD. The stability of the method was determined at 0.1–4.9% RSD. The developed method was used in the pilot studies for determining the enantiomers I (S), I (R), II (S), and II (R) in the blood serum.https://www.mdpi.com/1420-3049/26/4/993anticancer drugcapillary electrophoresischiral selectorsdrug monitoring |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Błażej Grodner Mariola Napiórkowska |
spellingShingle |
Błażej Grodner Mariola Napiórkowska Dual 2-Hydroxypropyl-β-Cyclodextrin and 5,10,15,20-Tetrakis (4-Hydroxyphenyl) Porphyrin System as a Novel Chiral-Achiral Selector Complex for Enantioseparation of Aminoalkanol Derivatives with Anticancer Activity in Capillary Electrophoresis Molecules anticancer drug capillary electrophoresis chiral selectors drug monitoring |
author_facet |
Błażej Grodner Mariola Napiórkowska |
author_sort |
Błażej Grodner |
title |
Dual 2-Hydroxypropyl-β-Cyclodextrin and 5,10,15,20-Tetrakis (4-Hydroxyphenyl) Porphyrin System as a Novel Chiral-Achiral Selector Complex for Enantioseparation of Aminoalkanol Derivatives with Anticancer Activity in Capillary Electrophoresis |
title_short |
Dual 2-Hydroxypropyl-β-Cyclodextrin and 5,10,15,20-Tetrakis (4-Hydroxyphenyl) Porphyrin System as a Novel Chiral-Achiral Selector Complex for Enantioseparation of Aminoalkanol Derivatives with Anticancer Activity in Capillary Electrophoresis |
title_full |
Dual 2-Hydroxypropyl-β-Cyclodextrin and 5,10,15,20-Tetrakis (4-Hydroxyphenyl) Porphyrin System as a Novel Chiral-Achiral Selector Complex for Enantioseparation of Aminoalkanol Derivatives with Anticancer Activity in Capillary Electrophoresis |
title_fullStr |
Dual 2-Hydroxypropyl-β-Cyclodextrin and 5,10,15,20-Tetrakis (4-Hydroxyphenyl) Porphyrin System as a Novel Chiral-Achiral Selector Complex for Enantioseparation of Aminoalkanol Derivatives with Anticancer Activity in Capillary Electrophoresis |
title_full_unstemmed |
Dual 2-Hydroxypropyl-β-Cyclodextrin and 5,10,15,20-Tetrakis (4-Hydroxyphenyl) Porphyrin System as a Novel Chiral-Achiral Selector Complex for Enantioseparation of Aminoalkanol Derivatives with Anticancer Activity in Capillary Electrophoresis |
title_sort |
dual 2-hydroxypropyl-β-cyclodextrin and 5,10,15,20-tetrakis (4-hydroxyphenyl) porphyrin system as a novel chiral-achiral selector complex for enantioseparation of aminoalkanol derivatives with anticancer activity in capillary electrophoresis |
publisher |
MDPI AG |
series |
Molecules |
issn |
1420-3049 |
publishDate |
2021-02-01 |
description |
In this study, a complex consisting of 2-hydroxypropyl-β-cyclodextrin and 5,10,15,20-tetrakis (4-hydroxyphenyl) porphyrin, (named dual chiral-achiral selector complex) was used for the determination of two novel potential anticancer agents of (I) and (II) aminoalkanol derivatives. This work aimed at developing an effective method that can be utilized for the determination of I (S), I (R), and II (S) and II (R) enantiomers of (I) and (II) compounds through the use of a dual chiral-achiral selector complex consisting of hydroxypropyl-β-cyclodextrin and 5,10,15,20-tetrakis (4-hydroxyphenyl) porphyrin system by applying capillary electrophoresis. This combination proved to be beneficial in achieving high separation selectivity due to the combined effects of different modes of chiral discrimination. The enantiomers of (I) and (II) compounds were separated within a very short time of 3.6–7.2 min, in pH 2.5 phosphate buffer containing 2-hydroxypropyl-β-cyclodextrin and 5,10,15,20-tetrakis (4-hydroxyphenyl) porphyrin system at a concentration of 5 and 10 mM, respectively, at 25 °C and +10 kV. The detection wavelength of the detector was set at 200 nm. The LOD for I (S), I (R), II (S), and II (R) was 65.2, 65.6, 65.1, and 65.7 ng/mL, respectively. LOQ for I (S), I (R), II (S), and II (R) was 216.5, 217.8, 217.1, and 218.1 ng/mL, respectively. Recovery was 94.9–99.9%. The repeatability and reproducibility of the method based on the values of the migration time, and the area under the peak was 0.3–2.9% RSD. The stability of the method was determined at 0.1–4.9% RSD. The developed method was used in the pilot studies for determining the enantiomers I (S), I (R), II (S), and II (R) in the blood serum. |
topic |
anticancer drug capillary electrophoresis chiral selectors drug monitoring |
url |
https://www.mdpi.com/1420-3049/26/4/993 |
work_keys_str_mv |
AT błazejgrodner dual2hydroxypropylbcyclodextrinand5101520tetrakis4hydroxyphenylporphyrinsystemasanovelchiralachiralselectorcomplexforenantioseparationofaminoalkanolderivativeswithanticanceractivityincapillaryelectrophoresis AT mariolanapiorkowska dual2hydroxypropylbcyclodextrinand5101520tetrakis4hydroxyphenylporphyrinsystemasanovelchiralachiralselectorcomplexforenantioseparationofaminoalkanolderivativeswithanticanceractivityincapillaryelectrophoresis |
_version_ |
1724271362771517440 |