The Effect of Fuel Mass Fraction on the Combustion and Fluid Flow in a Sulfur Recovery Unit Thermal Reactor

Sulfur recovery unit (SRU) thermal reactors are negatively affected by high temperature operation. In this paper, the effect of the fuel mass fraction on the combustion and fluid flow in a SRU thermal reactor is investigated numerically. Practical operating conditions for a petrochemical corporation...

Full description

Bibliographic Details
Main Author: Chun-Lang Yeh
Format: Article
Language:English
Published: MDPI AG 2016-11-01
Series:Applied Sciences
Subjects:
Online Access:http://www.mdpi.com/2076-3417/6/11/331
id doaj-91c2788c912f41cc885d36d006ee5932
record_format Article
spelling doaj-91c2788c912f41cc885d36d006ee59322020-11-25T00:59:55ZengMDPI AGApplied Sciences2076-34172016-11-0161133110.3390/app6110331app6110331The Effect of Fuel Mass Fraction on the Combustion and Fluid Flow in a Sulfur Recovery Unit Thermal ReactorChun-Lang Yeh0Department of Aeronautical Engineering, National Formosa University, Huwei, Yunlin 632, TaiwanSulfur recovery unit (SRU) thermal reactors are negatively affected by high temperature operation. In this paper, the effect of the fuel mass fraction on the combustion and fluid flow in a SRU thermal reactor is investigated numerically. Practical operating conditions for a petrochemical corporation in Taiwan are used as the design conditions for the discussion. The simulation results show that the present design condition is a fuel-rich (or air-lean) condition and gives acceptable sulfur recovery, hydrogen sulfide (H2S) destruction, sulfur dioxide (SO2) emissions and thermal reactor temperature for an oxygen-normal operation. However, for an oxygen-rich operation, the local maximum temperature exceeds the suggested maximum service temperature, although the average temperature is acceptable. The high temperature region must be inspected very carefully during the annual maintenance period if there are oxygen-rich operations. If the fuel mass fraction to the zone ahead of the choke ring (zone 1) is 0.0625 or 0.125, the average temperature in the zone behind the choke ring (zone 2) is higher than the zone 1 average temperature, which can damage the downstream heat exchanger tubes. If the zone 1 fuel mass fraction is reduced to ensure a lower zone 1 temperature, the temperature in zone 2 and the heat exchanger section must be monitored closely and the zone 2 wall and heat exchanger tubes must be inspected very carefully during the annual maintenance period. To determine a suitable fuel mass fraction for operation, a detailed numerical simulation should be performed first to find the stoichiometric fuel mass fraction which produces the most complete combustion and the highest temperature. This stoichiometric fuel mass fraction should be avoided because the high temperature could damage the zone 1 corner or the choke ring. A higher fuel mass fraction (i.e., fuel-rich or air-lean condition) is more suitable because it can avoid deteriorations of both zone 1 and heat exchanger tubes. Although a lower fuel mass fraction (i.e., fuel-lean or air-rich condition) can avoid deterioration of zone 1, the heat exchanger tubes may be damaged. This paper provides a guideline for adjusting the fuel mass fraction to reduce the high temperature inside the thermal reactor and to ensure an acceptable sulfur recovery.http://www.mdpi.com/2076-3417/6/11/331SRU thermal reactorfuel mass fractionsulfur recoveryH2S destructionSO2 emissionthermal reactor temperature
collection DOAJ
language English
format Article
sources DOAJ
author Chun-Lang Yeh
spellingShingle Chun-Lang Yeh
The Effect of Fuel Mass Fraction on the Combustion and Fluid Flow in a Sulfur Recovery Unit Thermal Reactor
Applied Sciences
SRU thermal reactor
fuel mass fraction
sulfur recovery
H2S destruction
SO2 emission
thermal reactor temperature
author_facet Chun-Lang Yeh
author_sort Chun-Lang Yeh
title The Effect of Fuel Mass Fraction on the Combustion and Fluid Flow in a Sulfur Recovery Unit Thermal Reactor
title_short The Effect of Fuel Mass Fraction on the Combustion and Fluid Flow in a Sulfur Recovery Unit Thermal Reactor
title_full The Effect of Fuel Mass Fraction on the Combustion and Fluid Flow in a Sulfur Recovery Unit Thermal Reactor
title_fullStr The Effect of Fuel Mass Fraction on the Combustion and Fluid Flow in a Sulfur Recovery Unit Thermal Reactor
title_full_unstemmed The Effect of Fuel Mass Fraction on the Combustion and Fluid Flow in a Sulfur Recovery Unit Thermal Reactor
title_sort effect of fuel mass fraction on the combustion and fluid flow in a sulfur recovery unit thermal reactor
publisher MDPI AG
series Applied Sciences
issn 2076-3417
publishDate 2016-11-01
description Sulfur recovery unit (SRU) thermal reactors are negatively affected by high temperature operation. In this paper, the effect of the fuel mass fraction on the combustion and fluid flow in a SRU thermal reactor is investigated numerically. Practical operating conditions for a petrochemical corporation in Taiwan are used as the design conditions for the discussion. The simulation results show that the present design condition is a fuel-rich (or air-lean) condition and gives acceptable sulfur recovery, hydrogen sulfide (H2S) destruction, sulfur dioxide (SO2) emissions and thermal reactor temperature for an oxygen-normal operation. However, for an oxygen-rich operation, the local maximum temperature exceeds the suggested maximum service temperature, although the average temperature is acceptable. The high temperature region must be inspected very carefully during the annual maintenance period if there are oxygen-rich operations. If the fuel mass fraction to the zone ahead of the choke ring (zone 1) is 0.0625 or 0.125, the average temperature in the zone behind the choke ring (zone 2) is higher than the zone 1 average temperature, which can damage the downstream heat exchanger tubes. If the zone 1 fuel mass fraction is reduced to ensure a lower zone 1 temperature, the temperature in zone 2 and the heat exchanger section must be monitored closely and the zone 2 wall and heat exchanger tubes must be inspected very carefully during the annual maintenance period. To determine a suitable fuel mass fraction for operation, a detailed numerical simulation should be performed first to find the stoichiometric fuel mass fraction which produces the most complete combustion and the highest temperature. This stoichiometric fuel mass fraction should be avoided because the high temperature could damage the zone 1 corner or the choke ring. A higher fuel mass fraction (i.e., fuel-rich or air-lean condition) is more suitable because it can avoid deteriorations of both zone 1 and heat exchanger tubes. Although a lower fuel mass fraction (i.e., fuel-lean or air-rich condition) can avoid deterioration of zone 1, the heat exchanger tubes may be damaged. This paper provides a guideline for adjusting the fuel mass fraction to reduce the high temperature inside the thermal reactor and to ensure an acceptable sulfur recovery.
topic SRU thermal reactor
fuel mass fraction
sulfur recovery
H2S destruction
SO2 emission
thermal reactor temperature
url http://www.mdpi.com/2076-3417/6/11/331
work_keys_str_mv AT chunlangyeh theeffectoffuelmassfractiononthecombustionandfluidflowinasulfurrecoveryunitthermalreactor
AT chunlangyeh effectoffuelmassfractiononthecombustionandfluidflowinasulfurrecoveryunitthermalreactor
_version_ 1725215424449085440