Effect of Angle of Impact on Dynamic Pressure of the Flip Bucket Jets
In this study, dynamic pressures due to impact of a ski jump out of a flip bucket downstream of a chute spillway model have been studied. Experiments were performed for five discharge (0.11, 0.18, 0.25, 0.32, 0.39 mP<sup>3</sup>P/s per unit width) and four jet impact angles (0P<sup>...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | fas |
Published: |
Shahid Chamran University of Ahvaz
2013-05-01
|
Series: | علوم و مهندسی آبیاری |
Subjects: | |
Online Access: | http://jise.scu.ac.ir/article_10806_a830e4bb86021cd10f88699f706f53a0.pdf |
id |
doaj-911a33a5f4d6488fa85de46afd80b1f3 |
---|---|
record_format |
Article |
spelling |
doaj-911a33a5f4d6488fa85de46afd80b1f32020-11-25T02:57:59ZfasShahid Chamran University of Ahvazعلوم و مهندسی آبیاری2588-59522588-59602013-05-0136111010806Effect of Angle of Impact on Dynamic Pressure of the Flip Bucket JetsManoochehr Fathimoghadam0Jalil Kermannezhad1Elham Ghanbariadiv2Maher Obeydavi3Faridaldin Hodaee4Professor, Shahid Chamran University, Ahwaz, Iran. HTUHMSc. in Water Structures, Shahid Chamran University of Ahwaz, Iran.Ph.D. Student, in Water Structure, Shahid Chamran University of Ahwaz, Iran.MSc. Student, in Water Structures, Shahid Chamran University of Ahwaz, Iran.MSc. Student, in Water Structures, Shahid Chamran University of Ahwaz, Iran.In this study, dynamic pressures due to impact of a ski jump out of a flip bucket downstream of a chute spillway model have been studied. Experiments were performed for five discharge (0.11, 0.18, 0.25, 0.32, 0.39 mP<sup>3</sup>P/s per unit width) and four jet impact angles (0P<sup>0</sup>P, 30P<sup>0</sup>P, 60P<sup>0</sup>P, 90P<sup>0</sup>P). Fluctuation of dynamic pressure was measured using a 250 mbar pressure transducer. Discharge (q), horizontal and vertical distance from the peak to jet impact location (L, H-h) and angle impact in downstream (θ) were considered as the main parameters affecting the dynamic pressure. Results showed that pressure coefficient is highly sensitive to horizontal and vertical distances to impact location as well as to the impact angle. Using dimensionless parameters, a power function was correlated for calculation of the dynamic pressure for variable impact angle. <br /> <br />http://jise.scu.ac.ir/article_10806_a830e4bb86021cd10f88699f706f53a0.pdfdynamic pressuresky jumpjet impacttransducer |
collection |
DOAJ |
language |
fas |
format |
Article |
sources |
DOAJ |
author |
Manoochehr Fathimoghadam Jalil Kermannezhad Elham Ghanbariadiv Maher Obeydavi Faridaldin Hodaee |
spellingShingle |
Manoochehr Fathimoghadam Jalil Kermannezhad Elham Ghanbariadiv Maher Obeydavi Faridaldin Hodaee Effect of Angle of Impact on Dynamic Pressure of the Flip Bucket Jets علوم و مهندسی آبیاری dynamic pressure sky jump jet impact transducer |
author_facet |
Manoochehr Fathimoghadam Jalil Kermannezhad Elham Ghanbariadiv Maher Obeydavi Faridaldin Hodaee |
author_sort |
Manoochehr Fathimoghadam |
title |
Effect of Angle of Impact on Dynamic Pressure of the Flip Bucket Jets |
title_short |
Effect of Angle of Impact on Dynamic Pressure of the Flip Bucket Jets |
title_full |
Effect of Angle of Impact on Dynamic Pressure of the Flip Bucket Jets |
title_fullStr |
Effect of Angle of Impact on Dynamic Pressure of the Flip Bucket Jets |
title_full_unstemmed |
Effect of Angle of Impact on Dynamic Pressure of the Flip Bucket Jets |
title_sort |
effect of angle of impact on dynamic pressure of the flip bucket jets |
publisher |
Shahid Chamran University of Ahvaz |
series |
علوم و مهندسی آبیاری |
issn |
2588-5952 2588-5960 |
publishDate |
2013-05-01 |
description |
In this study, dynamic pressures due to impact of a ski jump out of a flip bucket downstream of a chute spillway model have been studied. Experiments were performed for five discharge (0.11, 0.18, 0.25, 0.32, 0.39 mP<sup>3</sup>P/s per unit width) and four jet impact angles (0P<sup>0</sup>P, 30P<sup>0</sup>P, 60P<sup>0</sup>P, 90P<sup>0</sup>P). Fluctuation of dynamic pressure was measured using a 250 mbar pressure transducer. Discharge (q), horizontal and vertical distance from the peak to jet impact location (L, H-h) and angle impact in downstream (θ) were considered as the main parameters affecting the dynamic pressure. Results showed that pressure coefficient is highly sensitive to horizontal and vertical distances to impact location as well as to the impact angle. Using dimensionless parameters, a power function was correlated for calculation of the dynamic pressure for variable impact angle. <br /> <br /> |
topic |
dynamic pressure sky jump jet impact transducer |
url |
http://jise.scu.ac.ir/article_10806_a830e4bb86021cd10f88699f706f53a0.pdf |
work_keys_str_mv |
AT manoochehrfathimoghadam effectofangleofimpactondynamicpressureoftheflipbucketjets AT jalilkermannezhad effectofangleofimpactondynamicpressureoftheflipbucketjets AT elhamghanbariadiv effectofangleofimpactondynamicpressureoftheflipbucketjets AT maherobeydavi effectofangleofimpactondynamicpressureoftheflipbucketjets AT faridaldinhodaee effectofangleofimpactondynamicpressureoftheflipbucketjets |
_version_ |
1724709107718422528 |