Consistency of two eye anterior segment analysis systems measuring wave-front aberration before and after refractive surgery
AIM: To study the consistency of pre-operative and postoperative wave-front aberration between SCHWIND and SIRIUS eye anterior segment analysis system. <p>METHODS: Prospective control study. A total of 360 eyes of 180 patients with refractive errors in West China Hospital of Sichuan University...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Press of International Journal of Ophthalmology (IJO PRESS)
2018-11-01
|
Series: | Guoji Yanke Zazhi |
Subjects: | |
Online Access: | http://ies.ijo.cn/cn_publish/2018/11/201811016.pdf |
id |
doaj-90bc4858b47d431ba459098db2453032 |
---|---|
record_format |
Article |
spelling |
doaj-90bc4858b47d431ba459098db24530322020-11-24T21:46:46ZengPress of International Journal of Ophthalmology (IJO PRESS)Guoji Yanke Zazhi1672-51231672-51232018-11-0118112016201810.3980/j.issn.1672-5123.2018.11.16Consistency of two eye anterior segment analysis systems measuring wave-front aberration before and after refractive surgeryXiao-Lan Zhang0Shun-Qing Wang1Cheng-Shu Sun2Ke Ma3Department of Ophthalmology,West China Hospital, Sichuan University, Chengdu 610041, Sichuan Province, ChinaDepartment of Ophthalmology,West China Hospital, Sichuan University, Chengdu 610041, Sichuan Province, ChinaDepartment of Ophthalmology,West China Hospital, Sichuan University, Chengdu 610041, Sichuan Province, ChinaDepartment of Ophthalmology,West China Hospital, Sichuan University, Chengdu 610041, Sichuan Province, ChinaAIM: To study the consistency of pre-operative and postoperative wave-front aberration between SCHWIND and SIRIUS eye anterior segment analysis system. <p>METHODS: Prospective control study. A total of 360 eyes of 180 patients with refractive errors in West China Hospital of Sichuan University were selected. The data, including the degree and the direction of the flat axis and the steep axis, Kappa angle and a variety of high order wave-front aberrations, were measured by SCHWIND and SIRIUS anterior segment analyzers. The average value of each parameter was taken 5 times, and paired sample <i>t</i> test was used and the data was analyzed by SPSS22.0 software. <p>RESULTS: Flat axis degree and direction, steep axis degree and direction, coma, and trefoil were measured preoperatively and 1mo postoperatively by SCHWIND and by SIRIUS eye anterior segment analysis systems, and there were no statistically significant differences between the two machines(<i>P</i>>0.05). Kappa angle was measured 1mo postoperatively and there was no statistically significant differences(<i>P</i>>0.05). There was statistically significant difference(<i>P</i><0.01)preoperatively between two machines of high-order aberrations and spherical aberration(SpAb); values measured by SCHWIND were higher than those measured by SIRIUS. There was no statistically significant difference(<i>P</i>>0.05)between two machines of high-order aberrations or SpAb in 1mo postoperatively. <p>CONCLUSION: SCHWIND and SIRIUS anterior segment eye analysis system have a good consistency of wave-front aberration measurement before and after refractive surgery.http://ies.ijo.cn/cn_publish/2018/11/201811016.pdfanterior segment analyzerwave-front aberrationfemtosecond laser |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Xiao-Lan Zhang Shun-Qing Wang Cheng-Shu Sun Ke Ma |
spellingShingle |
Xiao-Lan Zhang Shun-Qing Wang Cheng-Shu Sun Ke Ma Consistency of two eye anterior segment analysis systems measuring wave-front aberration before and after refractive surgery Guoji Yanke Zazhi anterior segment analyzer wave-front aberration femtosecond laser |
author_facet |
Xiao-Lan Zhang Shun-Qing Wang Cheng-Shu Sun Ke Ma |
author_sort |
Xiao-Lan Zhang |
title |
Consistency of two eye anterior segment analysis systems measuring wave-front aberration before and after refractive surgery |
title_short |
Consistency of two eye anterior segment analysis systems measuring wave-front aberration before and after refractive surgery |
title_full |
Consistency of two eye anterior segment analysis systems measuring wave-front aberration before and after refractive surgery |
title_fullStr |
Consistency of two eye anterior segment analysis systems measuring wave-front aberration before and after refractive surgery |
title_full_unstemmed |
Consistency of two eye anterior segment analysis systems measuring wave-front aberration before and after refractive surgery |
title_sort |
consistency of two eye anterior segment analysis systems measuring wave-front aberration before and after refractive surgery |
publisher |
Press of International Journal of Ophthalmology (IJO PRESS) |
series |
Guoji Yanke Zazhi |
issn |
1672-5123 1672-5123 |
publishDate |
2018-11-01 |
description |
AIM: To study the consistency of pre-operative and postoperative wave-front aberration between SCHWIND and SIRIUS eye anterior segment analysis system. <p>METHODS: Prospective control study. A total of 360 eyes of 180 patients with refractive errors in West China Hospital of Sichuan University were selected. The data, including the degree and the direction of the flat axis and the steep axis, Kappa angle and a variety of high order wave-front aberrations, were measured by SCHWIND and SIRIUS anterior segment analyzers. The average value of each parameter was taken 5 times, and paired sample <i>t</i> test was used and the data was analyzed by SPSS22.0 software. <p>RESULTS: Flat axis degree and direction, steep axis degree and direction, coma, and trefoil were measured preoperatively and 1mo postoperatively by SCHWIND and by SIRIUS eye anterior segment analysis systems, and there were no statistically significant differences between the two machines(<i>P</i>>0.05). Kappa angle was measured 1mo postoperatively and there was no statistically significant differences(<i>P</i>>0.05). There was statistically significant difference(<i>P</i><0.01)preoperatively between two machines of high-order aberrations and spherical aberration(SpAb); values measured by SCHWIND were higher than those measured by SIRIUS. There was no statistically significant difference(<i>P</i>>0.05)between two machines of high-order aberrations or SpAb in 1mo postoperatively. <p>CONCLUSION: SCHWIND and SIRIUS anterior segment eye analysis system have a good consistency of wave-front aberration measurement before and after refractive surgery. |
topic |
anterior segment analyzer wave-front aberration femtosecond laser |
url |
http://ies.ijo.cn/cn_publish/2018/11/201811016.pdf |
work_keys_str_mv |
AT xiaolanzhang consistencyoftwoeyeanteriorsegmentanalysissystemsmeasuringwavefrontaberrationbeforeandafterrefractivesurgery AT shunqingwang consistencyoftwoeyeanteriorsegmentanalysissystemsmeasuringwavefrontaberrationbeforeandafterrefractivesurgery AT chengshusun consistencyoftwoeyeanteriorsegmentanalysissystemsmeasuringwavefrontaberrationbeforeandafterrefractivesurgery AT kema consistencyoftwoeyeanteriorsegmentanalysissystemsmeasuringwavefrontaberrationbeforeandafterrefractivesurgery |
_version_ |
1725900196167024640 |