Consistency of two eye anterior segment analysis systems measuring wave-front aberration before and after refractive surgery

AIM: To study the consistency of pre-operative and postoperative wave-front aberration between SCHWIND and SIRIUS eye anterior segment analysis system. <p>METHODS: Prospective control study. A total of 360 eyes of 180 patients with refractive errors in West China Hospital of Sichuan University...

Full description

Bibliographic Details
Main Authors: Xiao-Lan Zhang, Shun-Qing Wang, Cheng-Shu Sun, Ke Ma
Format: Article
Language:English
Published: Press of International Journal of Ophthalmology (IJO PRESS) 2018-11-01
Series:Guoji Yanke Zazhi
Subjects:
Online Access:http://ies.ijo.cn/cn_publish/2018/11/201811016.pdf
id doaj-90bc4858b47d431ba459098db2453032
record_format Article
spelling doaj-90bc4858b47d431ba459098db24530322020-11-24T21:46:46ZengPress of International Journal of Ophthalmology (IJO PRESS)Guoji Yanke Zazhi1672-51231672-51232018-11-0118112016201810.3980/j.issn.1672-5123.2018.11.16Consistency of two eye anterior segment analysis systems measuring wave-front aberration before and after refractive surgeryXiao-Lan Zhang0Shun-Qing Wang1Cheng-Shu Sun2Ke Ma3Department of Ophthalmology,West China Hospital, Sichuan University, Chengdu 610041, Sichuan Province, ChinaDepartment of Ophthalmology,West China Hospital, Sichuan University, Chengdu 610041, Sichuan Province, ChinaDepartment of Ophthalmology,West China Hospital, Sichuan University, Chengdu 610041, Sichuan Province, ChinaDepartment of Ophthalmology,West China Hospital, Sichuan University, Chengdu 610041, Sichuan Province, ChinaAIM: To study the consistency of pre-operative and postoperative wave-front aberration between SCHWIND and SIRIUS eye anterior segment analysis system. <p>METHODS: Prospective control study. A total of 360 eyes of 180 patients with refractive errors in West China Hospital of Sichuan University were selected. The data, including the degree and the direction of the flat axis and the steep axis, Kappa angle and a variety of high order wave-front aberrations, were measured by SCHWIND and SIRIUS anterior segment analyzers. The average value of each parameter was taken 5 times, and paired sample <i>t</i> test was used and the data was analyzed by SPSS22.0 software. <p>RESULTS: Flat axis degree and direction, steep axis degree and direction, coma, and trefoil were measured preoperatively and 1mo postoperatively by SCHWIND and by SIRIUS eye anterior segment analysis systems, and there were no statistically significant differences between the two machines(<i>P</i>>0.05). Kappa angle was measured 1mo postoperatively and there was no statistically significant differences(<i>P</i>>0.05). There was statistically significant difference(<i>P</i><0.01)preoperatively between two machines of high-order aberrations and spherical aberration(SpAb); values measured by SCHWIND were higher than those measured by SIRIUS. There was no statistically significant difference(<i>P</i>>0.05)between two machines of high-order aberrations or SpAb in 1mo postoperatively. <p>CONCLUSION: SCHWIND and SIRIUS anterior segment eye analysis system have a good consistency of wave-front aberration measurement before and after refractive surgery.http://ies.ijo.cn/cn_publish/2018/11/201811016.pdfanterior segment analyzerwave-front aberrationfemtosecond laser
collection DOAJ
language English
format Article
sources DOAJ
author Xiao-Lan Zhang
Shun-Qing Wang
Cheng-Shu Sun
Ke Ma
spellingShingle Xiao-Lan Zhang
Shun-Qing Wang
Cheng-Shu Sun
Ke Ma
Consistency of two eye anterior segment analysis systems measuring wave-front aberration before and after refractive surgery
Guoji Yanke Zazhi
anterior segment analyzer
wave-front aberration
femtosecond laser
author_facet Xiao-Lan Zhang
Shun-Qing Wang
Cheng-Shu Sun
Ke Ma
author_sort Xiao-Lan Zhang
title Consistency of two eye anterior segment analysis systems measuring wave-front aberration before and after refractive surgery
title_short Consistency of two eye anterior segment analysis systems measuring wave-front aberration before and after refractive surgery
title_full Consistency of two eye anterior segment analysis systems measuring wave-front aberration before and after refractive surgery
title_fullStr Consistency of two eye anterior segment analysis systems measuring wave-front aberration before and after refractive surgery
title_full_unstemmed Consistency of two eye anterior segment analysis systems measuring wave-front aberration before and after refractive surgery
title_sort consistency of two eye anterior segment analysis systems measuring wave-front aberration before and after refractive surgery
publisher Press of International Journal of Ophthalmology (IJO PRESS)
series Guoji Yanke Zazhi
issn 1672-5123
1672-5123
publishDate 2018-11-01
description AIM: To study the consistency of pre-operative and postoperative wave-front aberration between SCHWIND and SIRIUS eye anterior segment analysis system. <p>METHODS: Prospective control study. A total of 360 eyes of 180 patients with refractive errors in West China Hospital of Sichuan University were selected. The data, including the degree and the direction of the flat axis and the steep axis, Kappa angle and a variety of high order wave-front aberrations, were measured by SCHWIND and SIRIUS anterior segment analyzers. The average value of each parameter was taken 5 times, and paired sample <i>t</i> test was used and the data was analyzed by SPSS22.0 software. <p>RESULTS: Flat axis degree and direction, steep axis degree and direction, coma, and trefoil were measured preoperatively and 1mo postoperatively by SCHWIND and by SIRIUS eye anterior segment analysis systems, and there were no statistically significant differences between the two machines(<i>P</i>>0.05). Kappa angle was measured 1mo postoperatively and there was no statistically significant differences(<i>P</i>>0.05). There was statistically significant difference(<i>P</i><0.01)preoperatively between two machines of high-order aberrations and spherical aberration(SpAb); values measured by SCHWIND were higher than those measured by SIRIUS. There was no statistically significant difference(<i>P</i>>0.05)between two machines of high-order aberrations or SpAb in 1mo postoperatively. <p>CONCLUSION: SCHWIND and SIRIUS anterior segment eye analysis system have a good consistency of wave-front aberration measurement before and after refractive surgery.
topic anterior segment analyzer
wave-front aberration
femtosecond laser
url http://ies.ijo.cn/cn_publish/2018/11/201811016.pdf
work_keys_str_mv AT xiaolanzhang consistencyoftwoeyeanteriorsegmentanalysissystemsmeasuringwavefrontaberrationbeforeandafterrefractivesurgery
AT shunqingwang consistencyoftwoeyeanteriorsegmentanalysissystemsmeasuringwavefrontaberrationbeforeandafterrefractivesurgery
AT chengshusun consistencyoftwoeyeanteriorsegmentanalysissystemsmeasuringwavefrontaberrationbeforeandafterrefractivesurgery
AT kema consistencyoftwoeyeanteriorsegmentanalysissystemsmeasuringwavefrontaberrationbeforeandafterrefractivesurgery
_version_ 1725900196167024640