Numerical and experimental determination of in-structure temperature profiles

When building physics simulations are done initial conditions express the actual hygrothermal state of building envelope. For the temperature field simulations initial condition is represented by the initial temperature in the body profile at the start of heat transfer. In-structure temperature vari...

Full description

Bibliographic Details
Main Authors: Zozulák Marek, Katunský Dušan
Format: Article
Language:English
Published: Sciendo 2015-06-01
Series:Selected Scientific Papers: Journal of Civil Engineering
Subjects:
Online Access:https://doi.org/10.1515/sspjce-2015-0007
Description
Summary:When building physics simulations are done initial conditions express the actual hygrothermal state of building envelope. For the temperature field simulations initial condition is represented by the initial temperature in the body profile at the start of heat transfer. In-structure temperature varies quickly so temperature initial conditions are often neglected. Nevertheless in specific cases initial conditions have to be taken into an account even when simple temperature field simulations are done. The contribution shows various temperature initial conditions determination for insulated construction of outdoor test cell. Comparison of measured and calculated temperature profiles in structure shows correctness of start-up pre-calculation initial condition consideration