Comparison between Roche Integra 400 plus and Abbott Architect ci8200 in Alanine aminotransferase assay

Background: The aim of this work is to present the results of a comparative study between the ALT assay on Integra 400 plus Roche Diagnostic versus Architect ci8200 of Abbott Diagnostic. Methods: A total of 200 patients hospitalized in the various departments of the university hospital Mohammed VI o...

Full description

Bibliographic Details
Main Authors: Somiya Lamrabat, Amina Lyagoubi, Ouardia Bouayadi, Jalila Elmalki, Khadija Elkouche, Mohammed Bensalah, Mohammed Choukri
Format: Article
Language:English
Published: Elsevier 2019-05-01
Series:Practical Laboratory Medicine
Online Access:http://www.sciencedirect.com/science/article/pii/S2352551718301483
id doaj-8fedaa3ee08a45388c04929e60b38482
record_format Article
spelling doaj-8fedaa3ee08a45388c04929e60b384822020-11-25T01:18:39ZengElsevierPractical Laboratory Medicine2352-55172019-05-0115Comparison between Roche Integra 400 plus and Abbott Architect ci8200 in Alanine aminotransferase assaySomiya Lamrabat0Amina Lyagoubi1Ouardia Bouayadi2Jalila Elmalki3Khadija Elkouche4Mohammed Bensalah5Mohammed Choukri6Central Laboratory of Mohammed VI University Hospital of Oujda City, Morocco; Faculty of Medicine and Pharmacy, First Mohammed University, Oujda City, Morocco; Corresponding author. Iriss district, Street Ain Serrak, N° 817, Oujda city, Morocco.Central Laboratory of Mohammed VI University Hospital of Oujda City, Morocco; Faculty of Medicine and Pharmacy, First Mohammed University, Oujda City, MoroccoCentral Laboratory of Mohammed VI University Hospital of Oujda City, Morocco; Faculty of Medicine and Pharmacy, First Mohammed University, Oujda City, MoroccoCentral Laboratory of Mohammed VI University Hospital of Oujda City, Morocco; Faculty of Medicine and Pharmacy, First Mohammed University, Oujda City, MoroccoCentral Laboratory of Mohammed VI University Hospital of Oujda City, Morocco; Faculty of Medicine and Pharmacy, First Mohammed University, Oujda City, MoroccoCentral Laboratory of Mohammed VI University Hospital of Oujda City, Morocco; Faculty of Medicine and Pharmacy, First Mohammed University, Oujda City, MoroccoCentral Laboratory of Mohammed VI University Hospital of Oujda City, Morocco; Faculty of Medicine and Pharmacy, First Mohammed University, Oujda City, MoroccoBackground: The aim of this work is to present the results of a comparative study between the ALT assay on Integra 400 plus Roche Diagnostic versus Architect ci8200 of Abbott Diagnostic. Methods: A total of 200 patients hospitalized in the various departments of the university hospital Mohammed VI of Oujda were prospectively tested on two systems: Abbott Architect ci8200 and Roche Integra 400 plus. Both analyzers use the spectrophotometric technique by coupling the transamination reaction to the oxidation-reduction reaction at NAD. The agreement of the results between the different techniques was evaluated using the Bland-Altman difference diagram and the Passing-Bablok and Deming regression line. Results: There was a high concordance between the two assays: the equation of the Passing-Bablok line is YArchitect ​= ​−0,5625 ​+ ​0,9917 XIntegra with a correlation coefficient r2 = 0.999. The Bland-Altman diagram shows that the mean bias between the two methods is of the order of 1.1 IU/L and the difference between the ALT measurements by Architect and Integra is in the range of −1.4 to 3.6. Conclusion: Our study shows a high correlation of the ALT assay results between the architect ci8200 and Integra 400 plus. Keywords: Alanine aminotransferase, Comparison, Concordance, Roche diagnostic, Abbott diagnostichttp://www.sciencedirect.com/science/article/pii/S2352551718301483
collection DOAJ
language English
format Article
sources DOAJ
author Somiya Lamrabat
Amina Lyagoubi
Ouardia Bouayadi
Jalila Elmalki
Khadija Elkouche
Mohammed Bensalah
Mohammed Choukri
spellingShingle Somiya Lamrabat
Amina Lyagoubi
Ouardia Bouayadi
Jalila Elmalki
Khadija Elkouche
Mohammed Bensalah
Mohammed Choukri
Comparison between Roche Integra 400 plus and Abbott Architect ci8200 in Alanine aminotransferase assay
Practical Laboratory Medicine
author_facet Somiya Lamrabat
Amina Lyagoubi
Ouardia Bouayadi
Jalila Elmalki
Khadija Elkouche
Mohammed Bensalah
Mohammed Choukri
author_sort Somiya Lamrabat
title Comparison between Roche Integra 400 plus and Abbott Architect ci8200 in Alanine aminotransferase assay
title_short Comparison between Roche Integra 400 plus and Abbott Architect ci8200 in Alanine aminotransferase assay
title_full Comparison between Roche Integra 400 plus and Abbott Architect ci8200 in Alanine aminotransferase assay
title_fullStr Comparison between Roche Integra 400 plus and Abbott Architect ci8200 in Alanine aminotransferase assay
title_full_unstemmed Comparison between Roche Integra 400 plus and Abbott Architect ci8200 in Alanine aminotransferase assay
title_sort comparison between roche integra 400 plus and abbott architect ci8200 in alanine aminotransferase assay
publisher Elsevier
series Practical Laboratory Medicine
issn 2352-5517
publishDate 2019-05-01
description Background: The aim of this work is to present the results of a comparative study between the ALT assay on Integra 400 plus Roche Diagnostic versus Architect ci8200 of Abbott Diagnostic. Methods: A total of 200 patients hospitalized in the various departments of the university hospital Mohammed VI of Oujda were prospectively tested on two systems: Abbott Architect ci8200 and Roche Integra 400 plus. Both analyzers use the spectrophotometric technique by coupling the transamination reaction to the oxidation-reduction reaction at NAD. The agreement of the results between the different techniques was evaluated using the Bland-Altman difference diagram and the Passing-Bablok and Deming regression line. Results: There was a high concordance between the two assays: the equation of the Passing-Bablok line is YArchitect ​= ​−0,5625 ​+ ​0,9917 XIntegra with a correlation coefficient r2 = 0.999. The Bland-Altman diagram shows that the mean bias between the two methods is of the order of 1.1 IU/L and the difference between the ALT measurements by Architect and Integra is in the range of −1.4 to 3.6. Conclusion: Our study shows a high correlation of the ALT assay results between the architect ci8200 and Integra 400 plus. Keywords: Alanine aminotransferase, Comparison, Concordance, Roche diagnostic, Abbott diagnostic
url http://www.sciencedirect.com/science/article/pii/S2352551718301483
work_keys_str_mv AT somiyalamrabat comparisonbetweenrocheintegra400plusandabbottarchitectci8200inalanineaminotransferaseassay
AT aminalyagoubi comparisonbetweenrocheintegra400plusandabbottarchitectci8200inalanineaminotransferaseassay
AT ouardiabouayadi comparisonbetweenrocheintegra400plusandabbottarchitectci8200inalanineaminotransferaseassay
AT jalilaelmalki comparisonbetweenrocheintegra400plusandabbottarchitectci8200inalanineaminotransferaseassay
AT khadijaelkouche comparisonbetweenrocheintegra400plusandabbottarchitectci8200inalanineaminotransferaseassay
AT mohammedbensalah comparisonbetweenrocheintegra400plusandabbottarchitectci8200inalanineaminotransferaseassay
AT mohammedchoukri comparisonbetweenrocheintegra400plusandabbottarchitectci8200inalanineaminotransferaseassay
_version_ 1725141359962095616