Comparison between Roche Integra 400 plus and Abbott Architect ci8200 in Alanine aminotransferase assay
Background: The aim of this work is to present the results of a comparative study between the ALT assay on Integra 400 plus Roche Diagnostic versus Architect ci8200 of Abbott Diagnostic. Methods: A total of 200 patients hospitalized in the various departments of the university hospital Mohammed VI o...
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2019-05-01
|
Series: | Practical Laboratory Medicine |
Online Access: | http://www.sciencedirect.com/science/article/pii/S2352551718301483 |
id |
doaj-8fedaa3ee08a45388c04929e60b38482 |
---|---|
record_format |
Article |
spelling |
doaj-8fedaa3ee08a45388c04929e60b384822020-11-25T01:18:39ZengElsevierPractical Laboratory Medicine2352-55172019-05-0115Comparison between Roche Integra 400 plus and Abbott Architect ci8200 in Alanine aminotransferase assaySomiya Lamrabat0Amina Lyagoubi1Ouardia Bouayadi2Jalila Elmalki3Khadija Elkouche4Mohammed Bensalah5Mohammed Choukri6Central Laboratory of Mohammed VI University Hospital of Oujda City, Morocco; Faculty of Medicine and Pharmacy, First Mohammed University, Oujda City, Morocco; Corresponding author. Iriss district, Street Ain Serrak, N° 817, Oujda city, Morocco.Central Laboratory of Mohammed VI University Hospital of Oujda City, Morocco; Faculty of Medicine and Pharmacy, First Mohammed University, Oujda City, MoroccoCentral Laboratory of Mohammed VI University Hospital of Oujda City, Morocco; Faculty of Medicine and Pharmacy, First Mohammed University, Oujda City, MoroccoCentral Laboratory of Mohammed VI University Hospital of Oujda City, Morocco; Faculty of Medicine and Pharmacy, First Mohammed University, Oujda City, MoroccoCentral Laboratory of Mohammed VI University Hospital of Oujda City, Morocco; Faculty of Medicine and Pharmacy, First Mohammed University, Oujda City, MoroccoCentral Laboratory of Mohammed VI University Hospital of Oujda City, Morocco; Faculty of Medicine and Pharmacy, First Mohammed University, Oujda City, MoroccoCentral Laboratory of Mohammed VI University Hospital of Oujda City, Morocco; Faculty of Medicine and Pharmacy, First Mohammed University, Oujda City, MoroccoBackground: The aim of this work is to present the results of a comparative study between the ALT assay on Integra 400 plus Roche Diagnostic versus Architect ci8200 of Abbott Diagnostic. Methods: A total of 200 patients hospitalized in the various departments of the university hospital Mohammed VI of Oujda were prospectively tested on two systems: Abbott Architect ci8200 and Roche Integra 400 plus. Both analyzers use the spectrophotometric technique by coupling the transamination reaction to the oxidation-reduction reaction at NAD. The agreement of the results between the different techniques was evaluated using the Bland-Altman difference diagram and the Passing-Bablok and Deming regression line. Results: There was a high concordance between the two assays: the equation of the Passing-Bablok line is YArchitect = −0,5625 + 0,9917 XIntegra with a correlation coefficient r2 = 0.999. The Bland-Altman diagram shows that the mean bias between the two methods is of the order of 1.1 IU/L and the difference between the ALT measurements by Architect and Integra is in the range of −1.4 to 3.6. Conclusion: Our study shows a high correlation of the ALT assay results between the architect ci8200 and Integra 400 plus. Keywords: Alanine aminotransferase, Comparison, Concordance, Roche diagnostic, Abbott diagnostichttp://www.sciencedirect.com/science/article/pii/S2352551718301483 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Somiya Lamrabat Amina Lyagoubi Ouardia Bouayadi Jalila Elmalki Khadija Elkouche Mohammed Bensalah Mohammed Choukri |
spellingShingle |
Somiya Lamrabat Amina Lyagoubi Ouardia Bouayadi Jalila Elmalki Khadija Elkouche Mohammed Bensalah Mohammed Choukri Comparison between Roche Integra 400 plus and Abbott Architect ci8200 in Alanine aminotransferase assay Practical Laboratory Medicine |
author_facet |
Somiya Lamrabat Amina Lyagoubi Ouardia Bouayadi Jalila Elmalki Khadija Elkouche Mohammed Bensalah Mohammed Choukri |
author_sort |
Somiya Lamrabat |
title |
Comparison between Roche Integra 400 plus and Abbott Architect ci8200 in Alanine aminotransferase assay |
title_short |
Comparison between Roche Integra 400 plus and Abbott Architect ci8200 in Alanine aminotransferase assay |
title_full |
Comparison between Roche Integra 400 plus and Abbott Architect ci8200 in Alanine aminotransferase assay |
title_fullStr |
Comparison between Roche Integra 400 plus and Abbott Architect ci8200 in Alanine aminotransferase assay |
title_full_unstemmed |
Comparison between Roche Integra 400 plus and Abbott Architect ci8200 in Alanine aminotransferase assay |
title_sort |
comparison between roche integra 400 plus and abbott architect ci8200 in alanine aminotransferase assay |
publisher |
Elsevier |
series |
Practical Laboratory Medicine |
issn |
2352-5517 |
publishDate |
2019-05-01 |
description |
Background: The aim of this work is to present the results of a comparative study between the ALT assay on Integra 400 plus Roche Diagnostic versus Architect ci8200 of Abbott Diagnostic. Methods: A total of 200 patients hospitalized in the various departments of the university hospital Mohammed VI of Oujda were prospectively tested on two systems: Abbott Architect ci8200 and Roche Integra 400 plus. Both analyzers use the spectrophotometric technique by coupling the transamination reaction to the oxidation-reduction reaction at NAD. The agreement of the results between the different techniques was evaluated using the Bland-Altman difference diagram and the Passing-Bablok and Deming regression line. Results: There was a high concordance between the two assays: the equation of the Passing-Bablok line is YArchitect = −0,5625 + 0,9917 XIntegra with a correlation coefficient r2 = 0.999. The Bland-Altman diagram shows that the mean bias between the two methods is of the order of 1.1 IU/L and the difference between the ALT measurements by Architect and Integra is in the range of −1.4 to 3.6. Conclusion: Our study shows a high correlation of the ALT assay results between the architect ci8200 and Integra 400 plus. Keywords: Alanine aminotransferase, Comparison, Concordance, Roche diagnostic, Abbott diagnostic |
url |
http://www.sciencedirect.com/science/article/pii/S2352551718301483 |
work_keys_str_mv |
AT somiyalamrabat comparisonbetweenrocheintegra400plusandabbottarchitectci8200inalanineaminotransferaseassay AT aminalyagoubi comparisonbetweenrocheintegra400plusandabbottarchitectci8200inalanineaminotransferaseassay AT ouardiabouayadi comparisonbetweenrocheintegra400plusandabbottarchitectci8200inalanineaminotransferaseassay AT jalilaelmalki comparisonbetweenrocheintegra400plusandabbottarchitectci8200inalanineaminotransferaseassay AT khadijaelkouche comparisonbetweenrocheintegra400plusandabbottarchitectci8200inalanineaminotransferaseassay AT mohammedbensalah comparisonbetweenrocheintegra400plusandabbottarchitectci8200inalanineaminotransferaseassay AT mohammedchoukri comparisonbetweenrocheintegra400plusandabbottarchitectci8200inalanineaminotransferaseassay |