Interocular Symmetry of Macular Ganglion Cell Complex Thickness in Young Chinese Subjects.

To report interocular differences in macular ganglion cell complex (mGCC) thickness in young Chinese subjects using RTVue-100 optical coherence tomography (OCT).This was an observational, cross-sectional study. The mGCC thickness was measured in 158young Chinese subjects using RTVue-100 OCT. The nor...

Full description

Bibliographic Details
Main Authors: Minwen Zhou, Bing Lu, Jingke Zhao, Qiu Wang, Pengfei Zhang, Xiaodong Sun
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2016-01-01
Series:PLoS ONE
Online Access:http://europepmc.org/articles/PMC4959728?pdf=render
id doaj-8fd9d234948e40baac1f9db1db443d4c
record_format Article
spelling doaj-8fd9d234948e40baac1f9db1db443d4c2020-11-25T00:07:27ZengPublic Library of Science (PLoS)PLoS ONE1932-62032016-01-01117e015958310.1371/journal.pone.0159583Interocular Symmetry of Macular Ganglion Cell Complex Thickness in Young Chinese Subjects.Minwen ZhouBing LuJingke ZhaoQiu WangPengfei ZhangXiaodong SunTo report interocular differences in macular ganglion cell complex (mGCC) thickness in young Chinese subjects using RTVue-100 optical coherence tomography (OCT).This was an observational, cross-sectional study. The mGCC thickness was measured in 158young Chinese subjects using RTVue-100 OCT. The normal ranges of the interocular differences were determined as falling between the 2.5th and 97.5th percentiles. Right and left eyes were compared using a paired t test. Pearson correlation analysis was performed to assess the relationships between mGCC thickness and other potential factors. The relationships between the interocular difference in the average mGCC thickness and the potential factors were evaluated by univariate and multivariate linear regression analysis.The mean interocular difference in the average, superior, and inferior mGCC thickness were 0.19 ± 2.69 μm, 0.22 ±3.14 μm, and 0.25±3.34 μm, respectively, which were not statistically significant. The 2.5th and 97.5th percentiles of interocular difference for mean average mGCC thickness were -4.82μm and 4.38μm, for superior mGCC thickness, -6.67 μm and 7.04 μm, and for inferior mGCC thickness, -6.75 μm and 6.27 μm. There was a strong correlation between the right and left eyes for all the studied parameters, including spherical equivalent (SE) and axial length (AL). Interocular difference in SE (p = 0.007) were independently correlated with the interocular difference in average mGCC thickness.There was no significant relative interocular difference in mGCC thickness in young Chinese subjects. Interocular difference exceeding the normal limits should be considered significantly asymmetrical, and suggestive of pathology.http://europepmc.org/articles/PMC4959728?pdf=render
collection DOAJ
language English
format Article
sources DOAJ
author Minwen Zhou
Bing Lu
Jingke Zhao
Qiu Wang
Pengfei Zhang
Xiaodong Sun
spellingShingle Minwen Zhou
Bing Lu
Jingke Zhao
Qiu Wang
Pengfei Zhang
Xiaodong Sun
Interocular Symmetry of Macular Ganglion Cell Complex Thickness in Young Chinese Subjects.
PLoS ONE
author_facet Minwen Zhou
Bing Lu
Jingke Zhao
Qiu Wang
Pengfei Zhang
Xiaodong Sun
author_sort Minwen Zhou
title Interocular Symmetry of Macular Ganglion Cell Complex Thickness in Young Chinese Subjects.
title_short Interocular Symmetry of Macular Ganglion Cell Complex Thickness in Young Chinese Subjects.
title_full Interocular Symmetry of Macular Ganglion Cell Complex Thickness in Young Chinese Subjects.
title_fullStr Interocular Symmetry of Macular Ganglion Cell Complex Thickness in Young Chinese Subjects.
title_full_unstemmed Interocular Symmetry of Macular Ganglion Cell Complex Thickness in Young Chinese Subjects.
title_sort interocular symmetry of macular ganglion cell complex thickness in young chinese subjects.
publisher Public Library of Science (PLoS)
series PLoS ONE
issn 1932-6203
publishDate 2016-01-01
description To report interocular differences in macular ganglion cell complex (mGCC) thickness in young Chinese subjects using RTVue-100 optical coherence tomography (OCT).This was an observational, cross-sectional study. The mGCC thickness was measured in 158young Chinese subjects using RTVue-100 OCT. The normal ranges of the interocular differences were determined as falling between the 2.5th and 97.5th percentiles. Right and left eyes were compared using a paired t test. Pearson correlation analysis was performed to assess the relationships between mGCC thickness and other potential factors. The relationships between the interocular difference in the average mGCC thickness and the potential factors were evaluated by univariate and multivariate linear regression analysis.The mean interocular difference in the average, superior, and inferior mGCC thickness were 0.19 ± 2.69 μm, 0.22 ±3.14 μm, and 0.25±3.34 μm, respectively, which were not statistically significant. The 2.5th and 97.5th percentiles of interocular difference for mean average mGCC thickness were -4.82μm and 4.38μm, for superior mGCC thickness, -6.67 μm and 7.04 μm, and for inferior mGCC thickness, -6.75 μm and 6.27 μm. There was a strong correlation between the right and left eyes for all the studied parameters, including spherical equivalent (SE) and axial length (AL). Interocular difference in SE (p = 0.007) were independently correlated with the interocular difference in average mGCC thickness.There was no significant relative interocular difference in mGCC thickness in young Chinese subjects. Interocular difference exceeding the normal limits should be considered significantly asymmetrical, and suggestive of pathology.
url http://europepmc.org/articles/PMC4959728?pdf=render
work_keys_str_mv AT minwenzhou interocularsymmetryofmacularganglioncellcomplexthicknessinyoungchinesesubjects
AT binglu interocularsymmetryofmacularganglioncellcomplexthicknessinyoungchinesesubjects
AT jingkezhao interocularsymmetryofmacularganglioncellcomplexthicknessinyoungchinesesubjects
AT qiuwang interocularsymmetryofmacularganglioncellcomplexthicknessinyoungchinesesubjects
AT pengfeizhang interocularsymmetryofmacularganglioncellcomplexthicknessinyoungchinesesubjects
AT xiaodongsun interocularsymmetryofmacularganglioncellcomplexthicknessinyoungchinesesubjects
_version_ 1725418150825033728