Atypical Presentation of a Type 2 Endoleak following Emergency Open Repair of a Ruptured Abdominal Aortic Aneurysm
: Background: An endoleak is a common complication following EVAR. Specifically, a Type 2 endoleak occurs because of retrograde flow from lumbar vessels outside the endograft within the aneurysm sac. Even though it is common following EVAR, it has not been identified as a complication following ope...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2016-01-01
|
Series: | EJVES Short Reports |
Online Access: | http://www.sciencedirect.com/science/article/pii/S2405655316300226 |
id |
doaj-8fae078330dc4b6f85f5e93345f4748b |
---|---|
record_format |
Article |
spelling |
doaj-8fae078330dc4b6f85f5e93345f4748b2020-11-25T02:06:07ZengElsevierEJVES Short Reports2405-65532016-01-01332426Atypical Presentation of a Type 2 Endoleak following Emergency Open Repair of a Ruptured Abdominal Aortic AneurysmK. Sharma0P. Halandras1R. Milner2Central Michigan University College of Medicine, Mount Pleasant, MI, USA; Corresponding author. Central Michigan University College of Medicine, 1280 East Campus Drive, Mount Pleasant, MI 48859, USA.Division of Vascular Surgery and Endovascular Therapy, Loyola University Medical Center, Maywood, IL, USASection of Vascular Surgery and Endovascular Therapy, University of Chicago Medical Center, Chicago, IL, USA: Background: An endoleak is a common complication following EVAR. Specifically, a Type 2 endoleak occurs because of retrograde flow from lumbar vessels outside the endograft within the aneurysm sac. Even though it is common following EVAR, it has not been identified as a complication following open ruptured abdominal aortic aneurysm (AAA) repair. Report: A 73-year-old male underwent open repair of a ruptured AAA. Five months later, computed tomography revealed filling from a lumbar vessel mimicking a Type 2 “endoleak.” The initial ultrasound showed a single pair of lumbar vessels with aneurysm sac expansion 8 weeks later. The “endoleak” and expanding sac were treated, and the 2-year surveillance demonstrated sac shrinkage. Discussion: Because endoleak is a complication after EVAR, this case provides a unique presentation of Type 2 “endoleak” physiology following open repair of a ruptured AAA. It is believed that it is necessary to expand the list of possible complications after open ruptured AAA repair to include “endoleaks.” Keywords: Endoleak: EVAR, Ruptured aneurysm, Open abdominal aortic aneurysmhttp://www.sciencedirect.com/science/article/pii/S2405655316300226 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
K. Sharma P. Halandras R. Milner |
spellingShingle |
K. Sharma P. Halandras R. Milner Atypical Presentation of a Type 2 Endoleak following Emergency Open Repair of a Ruptured Abdominal Aortic Aneurysm EJVES Short Reports |
author_facet |
K. Sharma P. Halandras R. Milner |
author_sort |
K. Sharma |
title |
Atypical Presentation of a Type 2 Endoleak following Emergency Open Repair of a Ruptured Abdominal Aortic Aneurysm |
title_short |
Atypical Presentation of a Type 2 Endoleak following Emergency Open Repair of a Ruptured Abdominal Aortic Aneurysm |
title_full |
Atypical Presentation of a Type 2 Endoleak following Emergency Open Repair of a Ruptured Abdominal Aortic Aneurysm |
title_fullStr |
Atypical Presentation of a Type 2 Endoleak following Emergency Open Repair of a Ruptured Abdominal Aortic Aneurysm |
title_full_unstemmed |
Atypical Presentation of a Type 2 Endoleak following Emergency Open Repair of a Ruptured Abdominal Aortic Aneurysm |
title_sort |
atypical presentation of a type 2 endoleak following emergency open repair of a ruptured abdominal aortic aneurysm |
publisher |
Elsevier |
series |
EJVES Short Reports |
issn |
2405-6553 |
publishDate |
2016-01-01 |
description |
: Background: An endoleak is a common complication following EVAR. Specifically, a Type 2 endoleak occurs because of retrograde flow from lumbar vessels outside the endograft within the aneurysm sac. Even though it is common following EVAR, it has not been identified as a complication following open ruptured abdominal aortic aneurysm (AAA) repair. Report: A 73-year-old male underwent open repair of a ruptured AAA. Five months later, computed tomography revealed filling from a lumbar vessel mimicking a Type 2 “endoleak.” The initial ultrasound showed a single pair of lumbar vessels with aneurysm sac expansion 8 weeks later. The “endoleak” and expanding sac were treated, and the 2-year surveillance demonstrated sac shrinkage. Discussion: Because endoleak is a complication after EVAR, this case provides a unique presentation of Type 2 “endoleak” physiology following open repair of a ruptured AAA. It is believed that it is necessary to expand the list of possible complications after open ruptured AAA repair to include “endoleaks.” Keywords: Endoleak: EVAR, Ruptured aneurysm, Open abdominal aortic aneurysm |
url |
http://www.sciencedirect.com/science/article/pii/S2405655316300226 |
work_keys_str_mv |
AT ksharma atypicalpresentationofatype2endoleakfollowingemergencyopenrepairofarupturedabdominalaorticaneurysm AT phalandras atypicalpresentationofatype2endoleakfollowingemergencyopenrepairofarupturedabdominalaorticaneurysm AT rmilner atypicalpresentationofatype2endoleakfollowingemergencyopenrepairofarupturedabdominalaorticaneurysm |
_version_ |
1724934888136638464 |