A modified loop snare technique for the retrieval of a dislodged central venous catheter
A dislodged central venous port catheter is typically retrieved using an endovascular approach; however, the retrieval procedure poses a challenge for vascular specialists. The desired outcomes can be successfully achieved with the loop snare technique, an endovascular treatment method for the retri...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2020-12-01
|
Series: | Radiology Case Reports |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S1930043320305318 |
Summary: | A dislodged central venous port catheter is typically retrieved using an endovascular approach; however, the retrieval procedure poses a challenge for vascular specialists. The desired outcomes can be successfully achieved with the loop snare technique, an endovascular treatment method for the retrieval of a dislodged central venous port catheter. Herein, we present a case wherein the modified loop snare technique was used for successfully retrieving a dislodged central venous port catheter by reversing the tip of the guidewire inside the right ventricle and advancing it back into the snare. |
---|---|