An indirect online method for measuring the boiling rate of BFG boiler economizer
In blast furnace gas (BFG) boiler, high flow and large velocity of the flue gas will cause more heat to be absorbed by tail heating surfaces such as economizers. This will increase the probability of water boiling and vaporizing in economizer, which may cause safety accidents. Therefore, to facilita...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2020-02-01
|
Series: | Energy Reports |
Online Access: | http://www.sciencedirect.com/science/article/pii/S2352484719311229 |
id |
doaj-8f30194f6a584a318accf2a97141a4a9 |
---|---|
record_format |
Article |
spelling |
doaj-8f30194f6a584a318accf2a97141a4a92020-11-25T01:02:30ZengElsevierEnergy Reports2352-48472020-02-016703709An indirect online method for measuring the boiling rate of BFG boiler economizerYalan Ye0Hongming Wang1Xiang An2Corresponding author.; Jiangsu Maritime Institute, 309 Gezhi Road, Jiangning District, Nanjing 211170, China; Jiangsu Higher Vocational Colleges Research and Development Center for Engineering Technology of ship Energy Saving and Emission Reduction, 309 Gezhi Road, Jiangning District, Nanjing 211170, ChinaJiangsu Maritime Institute, 309 Gezhi Road, Jiangning District, Nanjing 211170, China; Jiangsu Higher Vocational Colleges Research and Development Center for Engineering Technology of ship Energy Saving and Emission Reduction, 309 Gezhi Road, Jiangning District, Nanjing 211170, ChinaJiangsu Maritime Institute, 309 Gezhi Road, Jiangning District, Nanjing 211170, China; Jiangsu Higher Vocational Colleges Research and Development Center for Engineering Technology of ship Energy Saving and Emission Reduction, 309 Gezhi Road, Jiangning District, Nanjing 211170, ChinaIn blast furnace gas (BFG) boiler, high flow and large velocity of the flue gas will cause more heat to be absorbed by tail heating surfaces such as economizers. This will increase the probability of water boiling and vaporizing in economizer, which may cause safety accidents. Therefore, to facilitate the safe operation of boilers, it is of vital importance to grasp the boiling rate of economizer in real time. However, due to the complex state of medium in the piping, it is difficult to measure the boiling rate of economizer directly. Aiming at this issue, this paper presents an indirect online method for measuring the boiling rate of BFG boiler economizer through boiler operation parameters, based on heat transfer balance calculation. In this method, the boiling rate of economizer can be obtained indirectly through the boiler operation parameters on flue gas side and steam–water side. The measuring result can be used as the basis for boiler operation and adjustment, thus make the economizer running in a safe state for a long time, which can prolong the operation life of economizer. Keywords: Boiling rate of economizer, BFG boiler, Heat transfer balance, Online calculation, Indirect measurementhttp://www.sciencedirect.com/science/article/pii/S2352484719311229 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Yalan Ye Hongming Wang Xiang An |
spellingShingle |
Yalan Ye Hongming Wang Xiang An An indirect online method for measuring the boiling rate of BFG boiler economizer Energy Reports |
author_facet |
Yalan Ye Hongming Wang Xiang An |
author_sort |
Yalan Ye |
title |
An indirect online method for measuring the boiling rate of BFG boiler economizer |
title_short |
An indirect online method for measuring the boiling rate of BFG boiler economizer |
title_full |
An indirect online method for measuring the boiling rate of BFG boiler economizer |
title_fullStr |
An indirect online method for measuring the boiling rate of BFG boiler economizer |
title_full_unstemmed |
An indirect online method for measuring the boiling rate of BFG boiler economizer |
title_sort |
indirect online method for measuring the boiling rate of bfg boiler economizer |
publisher |
Elsevier |
series |
Energy Reports |
issn |
2352-4847 |
publishDate |
2020-02-01 |
description |
In blast furnace gas (BFG) boiler, high flow and large velocity of the flue gas will cause more heat to be absorbed by tail heating surfaces such as economizers. This will increase the probability of water boiling and vaporizing in economizer, which may cause safety accidents. Therefore, to facilitate the safe operation of boilers, it is of vital importance to grasp the boiling rate of economizer in real time. However, due to the complex state of medium in the piping, it is difficult to measure the boiling rate of economizer directly. Aiming at this issue, this paper presents an indirect online method for measuring the boiling rate of BFG boiler economizer through boiler operation parameters, based on heat transfer balance calculation. In this method, the boiling rate of economizer can be obtained indirectly through the boiler operation parameters on flue gas side and steam–water side. The measuring result can be used as the basis for boiler operation and adjustment, thus make the economizer running in a safe state for a long time, which can prolong the operation life of economizer. Keywords: Boiling rate of economizer, BFG boiler, Heat transfer balance, Online calculation, Indirect measurement |
url |
http://www.sciencedirect.com/science/article/pii/S2352484719311229 |
work_keys_str_mv |
AT yalanye anindirectonlinemethodformeasuringtheboilingrateofbfgboilereconomizer AT hongmingwang anindirectonlinemethodformeasuringtheboilingrateofbfgboilereconomizer AT xiangan anindirectonlinemethodformeasuringtheboilingrateofbfgboilereconomizer AT yalanye indirectonlinemethodformeasuringtheboilingrateofbfgboilereconomizer AT hongmingwang indirectonlinemethodformeasuringtheboilingrateofbfgboilereconomizer AT xiangan indirectonlinemethodformeasuringtheboilingrateofbfgboilereconomizer |
_version_ |
1725204563556827136 |