An <i>in vitro</i> study to evaluate the effect of storage time and application of subsequent layers on the variation in thickness of three commercially available die spacers

<b>Aims</b> : The application of a paint-on die spacer onto the dies prior to the fabrication of cast crowns is an acceptable procedure to improve the fit of the restoration. The primary purpose of this study was to evaluate the variation in thickness of different brands of die spacer ba...

Full description

Bibliographic Details
Main Authors: Jacob Sunil, Hegde Chethan, Prasad Krishna, Shetty Manoj
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2010-01-01
Series:Indian Journal of Dental Research
Subjects:
Online Access:http://www.ijdr.in/article.asp?issn=0970-9290;year=2010;volume=21;issue=1;spage=92;epage=97;aulast=Jacob
id doaj-8eb2470d71764f2fa22dc1427633007a
record_format Article
spelling doaj-8eb2470d71764f2fa22dc1427633007a2020-11-24T22:12:48ZengWolters Kluwer Medknow PublicationsIndian Journal of Dental Research0970-92901998-36032010-01-012119297An <i>in vitro</i> study to evaluate the effect of storage time and application of subsequent layers on the variation in thickness of three commercially available die spacersJacob SunilHegde ChethanPrasad KrishnaShetty Manoj<b>Aims</b> : The application of a paint-on die spacer onto the dies prior to the fabrication of cast crowns is an acceptable procedure to improve the fit of the restoration. The primary purpose of this study was to evaluate the variation in thickness of different brands of die spacer based on the effect of storage time and application of additional layers. <b> Materials and Methods:</b> Dies were duplicated from a master model of ivorine teeth, with a full ceramic preparation. Dies obtained were then painted with one, two, and three coats of each brand of die-spacers separately. These dies were embedded in die stone and sectioned bucco-lingually. The same procedure was done after three and six months. The thickness of the paint on die spacer was measured at five points on the die using an optical microscope, and the data were statistically analyzed. <b>Results and Conclusion</b> : There was a definite variation in the thickness of the die spacer with all the three brands and at various points on the die. Two coat thicknesses were found to be in the range of tolerance of 20-40 microns. Thickness at occlusal groove was noted to be the maximum with least at occlusoaxial line angles. Thickness also showed a very significant increase when bottles were stored for a period of three to six months and then applied.http://www.ijdr.in/article.asp?issn=0970-9290;year=2010;volume=21;issue=1;spage=92;epage=97;aulast=JacobDie spacerinternal reliefocclusal grooveocclusoaxial line angle
collection DOAJ
language English
format Article
sources DOAJ
author Jacob Sunil
Hegde Chethan
Prasad Krishna
Shetty Manoj
spellingShingle Jacob Sunil
Hegde Chethan
Prasad Krishna
Shetty Manoj
An <i>in vitro</i> study to evaluate the effect of storage time and application of subsequent layers on the variation in thickness of three commercially available die spacers
Indian Journal of Dental Research
Die spacer
internal relief
occlusal groove
occlusoaxial line angle
author_facet Jacob Sunil
Hegde Chethan
Prasad Krishna
Shetty Manoj
author_sort Jacob Sunil
title An <i>in vitro</i> study to evaluate the effect of storage time and application of subsequent layers on the variation in thickness of three commercially available die spacers
title_short An <i>in vitro</i> study to evaluate the effect of storage time and application of subsequent layers on the variation in thickness of three commercially available die spacers
title_full An <i>in vitro</i> study to evaluate the effect of storage time and application of subsequent layers on the variation in thickness of three commercially available die spacers
title_fullStr An <i>in vitro</i> study to evaluate the effect of storage time and application of subsequent layers on the variation in thickness of three commercially available die spacers
title_full_unstemmed An <i>in vitro</i> study to evaluate the effect of storage time and application of subsequent layers on the variation in thickness of three commercially available die spacers
title_sort <i>in vitro</i> study to evaluate the effect of storage time and application of subsequent layers on the variation in thickness of three commercially available die spacers
publisher Wolters Kluwer Medknow Publications
series Indian Journal of Dental Research
issn 0970-9290
1998-3603
publishDate 2010-01-01
description <b>Aims</b> : The application of a paint-on die spacer onto the dies prior to the fabrication of cast crowns is an acceptable procedure to improve the fit of the restoration. The primary purpose of this study was to evaluate the variation in thickness of different brands of die spacer based on the effect of storage time and application of additional layers. <b> Materials and Methods:</b> Dies were duplicated from a master model of ivorine teeth, with a full ceramic preparation. Dies obtained were then painted with one, two, and three coats of each brand of die-spacers separately. These dies were embedded in die stone and sectioned bucco-lingually. The same procedure was done after three and six months. The thickness of the paint on die spacer was measured at five points on the die using an optical microscope, and the data were statistically analyzed. <b>Results and Conclusion</b> : There was a definite variation in the thickness of the die spacer with all the three brands and at various points on the die. Two coat thicknesses were found to be in the range of tolerance of 20-40 microns. Thickness at occlusal groove was noted to be the maximum with least at occlusoaxial line angles. Thickness also showed a very significant increase when bottles were stored for a period of three to six months and then applied.
topic Die spacer
internal relief
occlusal groove
occlusoaxial line angle
url http://www.ijdr.in/article.asp?issn=0970-9290;year=2010;volume=21;issue=1;spage=92;epage=97;aulast=Jacob
work_keys_str_mv AT jacobsunil aniinvitroistudytoevaluatetheeffectofstoragetimeandapplicationofsubsequentlayersonthevariationinthicknessofthreecommerciallyavailablediespacers
AT hegdechethan aniinvitroistudytoevaluatetheeffectofstoragetimeandapplicationofsubsequentlayersonthevariationinthicknessofthreecommerciallyavailablediespacers
AT prasadkrishna aniinvitroistudytoevaluatetheeffectofstoragetimeandapplicationofsubsequentlayersonthevariationinthicknessofthreecommerciallyavailablediespacers
AT shettymanoj aniinvitroistudytoevaluatetheeffectofstoragetimeandapplicationofsubsequentlayersonthevariationinthicknessofthreecommerciallyavailablediespacers
AT jacobsunil iinvitroistudytoevaluatetheeffectofstoragetimeandapplicationofsubsequentlayersonthevariationinthicknessofthreecommerciallyavailablediespacers
AT hegdechethan iinvitroistudytoevaluatetheeffectofstoragetimeandapplicationofsubsequentlayersonthevariationinthicknessofthreecommerciallyavailablediespacers
AT prasadkrishna iinvitroistudytoevaluatetheeffectofstoragetimeandapplicationofsubsequentlayersonthevariationinthicknessofthreecommerciallyavailablediespacers
AT shettymanoj iinvitroistudytoevaluatetheeffectofstoragetimeandapplicationofsubsequentlayersonthevariationinthicknessofthreecommerciallyavailablediespacers
_version_ 1725802424459853824