Specificity in the Optical Excitation Lock-in Thermography Results Processing

The aim of the paper is to study some factors influence on the contrast decreasing of the ampligram and phasegram obtained after optical lock-in thermography. It is analysed the effect of delay between excitation source modulated parameter changing and modulated signal due to thermal inertia of halo...

Full description

Bibliographic Details
Main Authors: Stoynova Anna, Bonev Borislav
Format: Article
Language:English
Published: EDP Sciences 2017-01-01
Series:MATEC Web of Conferences
Online Access:https://doi.org/10.1051/matecconf/201712505016
id doaj-8e66a319bfef4097ac7a8b408358cfee
record_format Article
spelling doaj-8e66a319bfef4097ac7a8b408358cfee2021-02-02T03:41:47ZengEDP SciencesMATEC Web of Conferences2261-236X2017-01-011250501610.1051/matecconf/201712505016matecconf_cscc2017_05016Specificity in the Optical Excitation Lock-in Thermography Results ProcessingStoynova Anna0Bonev Borislav1Technical University of Sofia, Department of MicroelectronicsTechnical University of Sofia, Department of MicroelectronicsThe aim of the paper is to study some factors influence on the contrast decreasing of the ampligram and phasegram obtained after optical lock-in thermography. It is analysed the effect of delay between excitation source modulated parameter changing and modulated signal due to thermal inertia of halogen lamp filament. Two software corrections for decreasing the effect of these factors are developed. In order to evaluate the effect of these corrections, lock-in thermography measurement is performed and multiple results processing at different correction parameters values are performed. The contrast dependence from correction parameters is presented in graphical form. Multiple results processing with random correction parameters values using the both corrections are performed for determination of maximum possible contrast An iterative method with less number of results processing for choosing appropriate values of correction parameters using the both corrections is proposed. The effect of this method is presented and compared in tabular and graphic form.https://doi.org/10.1051/matecconf/201712505016
collection DOAJ
language English
format Article
sources DOAJ
author Stoynova Anna
Bonev Borislav
spellingShingle Stoynova Anna
Bonev Borislav
Specificity in the Optical Excitation Lock-in Thermography Results Processing
MATEC Web of Conferences
author_facet Stoynova Anna
Bonev Borislav
author_sort Stoynova Anna
title Specificity in the Optical Excitation Lock-in Thermography Results Processing
title_short Specificity in the Optical Excitation Lock-in Thermography Results Processing
title_full Specificity in the Optical Excitation Lock-in Thermography Results Processing
title_fullStr Specificity in the Optical Excitation Lock-in Thermography Results Processing
title_full_unstemmed Specificity in the Optical Excitation Lock-in Thermography Results Processing
title_sort specificity in the optical excitation lock-in thermography results processing
publisher EDP Sciences
series MATEC Web of Conferences
issn 2261-236X
publishDate 2017-01-01
description The aim of the paper is to study some factors influence on the contrast decreasing of the ampligram and phasegram obtained after optical lock-in thermography. It is analysed the effect of delay between excitation source modulated parameter changing and modulated signal due to thermal inertia of halogen lamp filament. Two software corrections for decreasing the effect of these factors are developed. In order to evaluate the effect of these corrections, lock-in thermography measurement is performed and multiple results processing at different correction parameters values are performed. The contrast dependence from correction parameters is presented in graphical form. Multiple results processing with random correction parameters values using the both corrections are performed for determination of maximum possible contrast An iterative method with less number of results processing for choosing appropriate values of correction parameters using the both corrections is proposed. The effect of this method is presented and compared in tabular and graphic form.
url https://doi.org/10.1051/matecconf/201712505016
work_keys_str_mv AT stoynovaanna specificityintheopticalexcitationlockinthermographyresultsprocessing
AT bonevborislav specificityintheopticalexcitationlockinthermographyresultsprocessing
_version_ 1724307260266512384