Time-Dependent Cytokine-Release of Platelet-Rich Plasma in 3-Chamber Co-Culture Device and Conventional Culture Well

Platelet-rich plasma (PRP) contains bioactive cytokines to enhance tissue healing. The best PRP preparation protocol and timing of the treatment have not been determined yet. To screen the best-fit PRP, a 3-chamber co-culture device was developed. We hypothesized the concentrations of the cytokines...

Full description

Bibliographic Details
Main Authors: Chih-Hao Chiu, Poyu Chen, Alvin Chao-Yu Chen, Yi-Sheng Chan, Kuo-Yao Hsu, Kin Fong Lei
Format: Article
Language:English
Published: MDPI AG 2021-07-01
Series:Applied Sciences
Subjects:
Online Access:https://www.mdpi.com/2076-3417/11/15/6947
id doaj-8e26b9a450d94923b3d72d0aecf9c4b7
record_format Article
spelling doaj-8e26b9a450d94923b3d72d0aecf9c4b72021-08-06T15:19:14ZengMDPI AGApplied Sciences2076-34172021-07-01116947694710.3390/app11156947Time-Dependent Cytokine-Release of Platelet-Rich Plasma in 3-Chamber Co-Culture Device and Conventional Culture WellChih-Hao Chiu0Poyu Chen1Alvin Chao-Yu Chen2Yi-Sheng Chan3Kuo-Yao Hsu4Kin Fong Lei5Department of Orthopedic Surgery, Taoyuan Chang Gung Memorial Hospital, Taoyuan 333, TaiwanDepartment of Orthopedic Surgery, Taoyuan Chang Gung Memorial Hospital, Taoyuan 333, TaiwanDepartment of Orthopedic Surgery, Linkou Chang Gung Memorial Hospital, Taoyuan 333, TaiwanDepartment of Orthopedic Surgery, Linkou Chang Gung Memorial Hospital, Taoyuan 333, TaiwanDepartment of Orthopedic Surgery, Linkou Chang Gung Memorial Hospital, Taoyuan 333, TaiwanGraduate Institute of Biomedical Engineering, Chang Gung University, Taoyuan 333, TaiwanPlatelet-rich plasma (PRP) contains bioactive cytokines to enhance tissue healing. The best PRP preparation protocol and timing of the treatment have not been determined yet. To screen the best-fit PRP, a 3-chamber co-culture device was developed. We hypothesized the concentrations of the cytokines from different PRPs in the co-culture plates had a high correlation with those in conventional 24-well culture plates at different time points. The concentrations of the cytokine from PRPs would be correlated with platelet concentrations. The correlation of transforming growth factor beta-1 (TGF-β1) and platelet-derived growth factor AB (PDGF-AB) in both devices were compared at 0, 24, 48, 72, and 96 h from two PRPs as well as that of platelet and cytokines concentrations. The results revealed that there was a moderate to high correlation in TGF-β1 concentrations between the 3-chamber co-culture and conventional culture device until 96 h. The correlation of PDGF-AB concentrations in both devices had moderate to high correlation in the first 24 h, and then it became modestly correlated from 48 to 96 h. A high correlation was found between platelet and TGF-β1 concentration at 96 h. However, they were modestly correlated in other time points. A negative or modest correlation was found between platelet and PDGF-AB concentration in all time points. In conclusion, TGF-β1 and PDGF-AB revealed a time-dependent manner of release at five time points. There is a moderate to high correlation of the TGF-β1 and PDGF-AB concentration in both devices at different time points. However, TGF-β1 and PDGF-AB concentrations are not always proportional to the platelet concentration of the PRPs.https://www.mdpi.com/2076-3417/11/15/6947platelet-rich plasmaco-cultureTGF-β1PDGF-ABtime-dependent
collection DOAJ
language English
format Article
sources DOAJ
author Chih-Hao Chiu
Poyu Chen
Alvin Chao-Yu Chen
Yi-Sheng Chan
Kuo-Yao Hsu
Kin Fong Lei
spellingShingle Chih-Hao Chiu
Poyu Chen
Alvin Chao-Yu Chen
Yi-Sheng Chan
Kuo-Yao Hsu
Kin Fong Lei
Time-Dependent Cytokine-Release of Platelet-Rich Plasma in 3-Chamber Co-Culture Device and Conventional Culture Well
Applied Sciences
platelet-rich plasma
co-culture
TGF-β1
PDGF-AB
time-dependent
author_facet Chih-Hao Chiu
Poyu Chen
Alvin Chao-Yu Chen
Yi-Sheng Chan
Kuo-Yao Hsu
Kin Fong Lei
author_sort Chih-Hao Chiu
title Time-Dependent Cytokine-Release of Platelet-Rich Plasma in 3-Chamber Co-Culture Device and Conventional Culture Well
title_short Time-Dependent Cytokine-Release of Platelet-Rich Plasma in 3-Chamber Co-Culture Device and Conventional Culture Well
title_full Time-Dependent Cytokine-Release of Platelet-Rich Plasma in 3-Chamber Co-Culture Device and Conventional Culture Well
title_fullStr Time-Dependent Cytokine-Release of Platelet-Rich Plasma in 3-Chamber Co-Culture Device and Conventional Culture Well
title_full_unstemmed Time-Dependent Cytokine-Release of Platelet-Rich Plasma in 3-Chamber Co-Culture Device and Conventional Culture Well
title_sort time-dependent cytokine-release of platelet-rich plasma in 3-chamber co-culture device and conventional culture well
publisher MDPI AG
series Applied Sciences
issn 2076-3417
publishDate 2021-07-01
description Platelet-rich plasma (PRP) contains bioactive cytokines to enhance tissue healing. The best PRP preparation protocol and timing of the treatment have not been determined yet. To screen the best-fit PRP, a 3-chamber co-culture device was developed. We hypothesized the concentrations of the cytokines from different PRPs in the co-culture plates had a high correlation with those in conventional 24-well culture plates at different time points. The concentrations of the cytokine from PRPs would be correlated with platelet concentrations. The correlation of transforming growth factor beta-1 (TGF-β1) and platelet-derived growth factor AB (PDGF-AB) in both devices were compared at 0, 24, 48, 72, and 96 h from two PRPs as well as that of platelet and cytokines concentrations. The results revealed that there was a moderate to high correlation in TGF-β1 concentrations between the 3-chamber co-culture and conventional culture device until 96 h. The correlation of PDGF-AB concentrations in both devices had moderate to high correlation in the first 24 h, and then it became modestly correlated from 48 to 96 h. A high correlation was found between platelet and TGF-β1 concentration at 96 h. However, they were modestly correlated in other time points. A negative or modest correlation was found between platelet and PDGF-AB concentration in all time points. In conclusion, TGF-β1 and PDGF-AB revealed a time-dependent manner of release at five time points. There is a moderate to high correlation of the TGF-β1 and PDGF-AB concentration in both devices at different time points. However, TGF-β1 and PDGF-AB concentrations are not always proportional to the platelet concentration of the PRPs.
topic platelet-rich plasma
co-culture
TGF-β1
PDGF-AB
time-dependent
url https://www.mdpi.com/2076-3417/11/15/6947
work_keys_str_mv AT chihhaochiu timedependentcytokinereleaseofplateletrichplasmain3chambercoculturedeviceandconventionalculturewell
AT poyuchen timedependentcytokinereleaseofplateletrichplasmain3chambercoculturedeviceandconventionalculturewell
AT alvinchaoyuchen timedependentcytokinereleaseofplateletrichplasmain3chambercoculturedeviceandconventionalculturewell
AT yishengchan timedependentcytokinereleaseofplateletrichplasmain3chambercoculturedeviceandconventionalculturewell
AT kuoyaohsu timedependentcytokinereleaseofplateletrichplasmain3chambercoculturedeviceandconventionalculturewell
AT kinfonglei timedependentcytokinereleaseofplateletrichplasmain3chambercoculturedeviceandconventionalculturewell
_version_ 1721218930850136064