Time-Dependent Cytokine-Release of Platelet-Rich Plasma in 3-Chamber Co-Culture Device and Conventional Culture Well
Platelet-rich plasma (PRP) contains bioactive cytokines to enhance tissue healing. The best PRP preparation protocol and timing of the treatment have not been determined yet. To screen the best-fit PRP, a 3-chamber co-culture device was developed. We hypothesized the concentrations of the cytokines...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2021-07-01
|
Series: | Applied Sciences |
Subjects: | |
Online Access: | https://www.mdpi.com/2076-3417/11/15/6947 |
id |
doaj-8e26b9a450d94923b3d72d0aecf9c4b7 |
---|---|
record_format |
Article |
spelling |
doaj-8e26b9a450d94923b3d72d0aecf9c4b72021-08-06T15:19:14ZengMDPI AGApplied Sciences2076-34172021-07-01116947694710.3390/app11156947Time-Dependent Cytokine-Release of Platelet-Rich Plasma in 3-Chamber Co-Culture Device and Conventional Culture WellChih-Hao Chiu0Poyu Chen1Alvin Chao-Yu Chen2Yi-Sheng Chan3Kuo-Yao Hsu4Kin Fong Lei5Department of Orthopedic Surgery, Taoyuan Chang Gung Memorial Hospital, Taoyuan 333, TaiwanDepartment of Orthopedic Surgery, Taoyuan Chang Gung Memorial Hospital, Taoyuan 333, TaiwanDepartment of Orthopedic Surgery, Linkou Chang Gung Memorial Hospital, Taoyuan 333, TaiwanDepartment of Orthopedic Surgery, Linkou Chang Gung Memorial Hospital, Taoyuan 333, TaiwanDepartment of Orthopedic Surgery, Linkou Chang Gung Memorial Hospital, Taoyuan 333, TaiwanGraduate Institute of Biomedical Engineering, Chang Gung University, Taoyuan 333, TaiwanPlatelet-rich plasma (PRP) contains bioactive cytokines to enhance tissue healing. The best PRP preparation protocol and timing of the treatment have not been determined yet. To screen the best-fit PRP, a 3-chamber co-culture device was developed. We hypothesized the concentrations of the cytokines from different PRPs in the co-culture plates had a high correlation with those in conventional 24-well culture plates at different time points. The concentrations of the cytokine from PRPs would be correlated with platelet concentrations. The correlation of transforming growth factor beta-1 (TGF-β1) and platelet-derived growth factor AB (PDGF-AB) in both devices were compared at 0, 24, 48, 72, and 96 h from two PRPs as well as that of platelet and cytokines concentrations. The results revealed that there was a moderate to high correlation in TGF-β1 concentrations between the 3-chamber co-culture and conventional culture device until 96 h. The correlation of PDGF-AB concentrations in both devices had moderate to high correlation in the first 24 h, and then it became modestly correlated from 48 to 96 h. A high correlation was found between platelet and TGF-β1 concentration at 96 h. However, they were modestly correlated in other time points. A negative or modest correlation was found between platelet and PDGF-AB concentration in all time points. In conclusion, TGF-β1 and PDGF-AB revealed a time-dependent manner of release at five time points. There is a moderate to high correlation of the TGF-β1 and PDGF-AB concentration in both devices at different time points. However, TGF-β1 and PDGF-AB concentrations are not always proportional to the platelet concentration of the PRPs.https://www.mdpi.com/2076-3417/11/15/6947platelet-rich plasmaco-cultureTGF-β1PDGF-ABtime-dependent |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Chih-Hao Chiu Poyu Chen Alvin Chao-Yu Chen Yi-Sheng Chan Kuo-Yao Hsu Kin Fong Lei |
spellingShingle |
Chih-Hao Chiu Poyu Chen Alvin Chao-Yu Chen Yi-Sheng Chan Kuo-Yao Hsu Kin Fong Lei Time-Dependent Cytokine-Release of Platelet-Rich Plasma in 3-Chamber Co-Culture Device and Conventional Culture Well Applied Sciences platelet-rich plasma co-culture TGF-β1 PDGF-AB time-dependent |
author_facet |
Chih-Hao Chiu Poyu Chen Alvin Chao-Yu Chen Yi-Sheng Chan Kuo-Yao Hsu Kin Fong Lei |
author_sort |
Chih-Hao Chiu |
title |
Time-Dependent Cytokine-Release of Platelet-Rich Plasma in 3-Chamber Co-Culture Device and Conventional Culture Well |
title_short |
Time-Dependent Cytokine-Release of Platelet-Rich Plasma in 3-Chamber Co-Culture Device and Conventional Culture Well |
title_full |
Time-Dependent Cytokine-Release of Platelet-Rich Plasma in 3-Chamber Co-Culture Device and Conventional Culture Well |
title_fullStr |
Time-Dependent Cytokine-Release of Platelet-Rich Plasma in 3-Chamber Co-Culture Device and Conventional Culture Well |
title_full_unstemmed |
Time-Dependent Cytokine-Release of Platelet-Rich Plasma in 3-Chamber Co-Culture Device and Conventional Culture Well |
title_sort |
time-dependent cytokine-release of platelet-rich plasma in 3-chamber co-culture device and conventional culture well |
publisher |
MDPI AG |
series |
Applied Sciences |
issn |
2076-3417 |
publishDate |
2021-07-01 |
description |
Platelet-rich plasma (PRP) contains bioactive cytokines to enhance tissue healing. The best PRP preparation protocol and timing of the treatment have not been determined yet. To screen the best-fit PRP, a 3-chamber co-culture device was developed. We hypothesized the concentrations of the cytokines from different PRPs in the co-culture plates had a high correlation with those in conventional 24-well culture plates at different time points. The concentrations of the cytokine from PRPs would be correlated with platelet concentrations. The correlation of transforming growth factor beta-1 (TGF-β1) and platelet-derived growth factor AB (PDGF-AB) in both devices were compared at 0, 24, 48, 72, and 96 h from two PRPs as well as that of platelet and cytokines concentrations. The results revealed that there was a moderate to high correlation in TGF-β1 concentrations between the 3-chamber co-culture and conventional culture device until 96 h. The correlation of PDGF-AB concentrations in both devices had moderate to high correlation in the first 24 h, and then it became modestly correlated from 48 to 96 h. A high correlation was found between platelet and TGF-β1 concentration at 96 h. However, they were modestly correlated in other time points. A negative or modest correlation was found between platelet and PDGF-AB concentration in all time points. In conclusion, TGF-β1 and PDGF-AB revealed a time-dependent manner of release at five time points. There is a moderate to high correlation of the TGF-β1 and PDGF-AB concentration in both devices at different time points. However, TGF-β1 and PDGF-AB concentrations are not always proportional to the platelet concentration of the PRPs. |
topic |
platelet-rich plasma co-culture TGF-β1 PDGF-AB time-dependent |
url |
https://www.mdpi.com/2076-3417/11/15/6947 |
work_keys_str_mv |
AT chihhaochiu timedependentcytokinereleaseofplateletrichplasmain3chambercoculturedeviceandconventionalculturewell AT poyuchen timedependentcytokinereleaseofplateletrichplasmain3chambercoculturedeviceandconventionalculturewell AT alvinchaoyuchen timedependentcytokinereleaseofplateletrichplasmain3chambercoculturedeviceandconventionalculturewell AT yishengchan timedependentcytokinereleaseofplateletrichplasmain3chambercoculturedeviceandconventionalculturewell AT kuoyaohsu timedependentcytokinereleaseofplateletrichplasmain3chambercoculturedeviceandconventionalculturewell AT kinfonglei timedependentcytokinereleaseofplateletrichplasmain3chambercoculturedeviceandconventionalculturewell |
_version_ |
1721218930850136064 |