Object-Oriented Economic Power Dispatch of Electrical Power System with minimum pollution using a Genetic Algorithm

This paper presents solution of optimal power flow (OPF) problem of electrical power system via a genetic algorithm of real type. The objective is to minimize the total fuel cost of generation and environmental pollution caused by fossil based thermal generating units and also maintain an acceptable...

Full description

Bibliographic Details
Main Authors: T. Bouktir, L. Slimani
Format: Article
Language:English
Published: ESRGroups 2005-06-01
Series:Journal of Electrical Systems
Subjects:
Online Access:http://journal.esrgroups.org/jes/papers/1_2_2.pdf
id doaj-8e17ad887b0f4ad097fe0da247420989
record_format Article
spelling doaj-8e17ad887b0f4ad097fe0da2474209892020-11-25T02:39:49ZengESRGroupsJournal of Electrical Systems1112-52092005-06-01121934Object-Oriented Economic Power Dispatch of Electrical Power System with minimum pollution using a Genetic AlgorithmT. BouktirL. SlimaniThis paper presents solution of optimal power flow (OPF) problem of electrical power system via a genetic algorithm of real type. The objective is to minimize the total fuel cost of generation and environmental pollution caused by fossil based thermal generating units and also maintain an acceptable system performance in terms of limits on generator real and reactive power outputs, bus voltages, shunt capacitors/reactors, transformers tap-setting and power flow of transmission lines. CPU times can be reduced by decomposing the optimization constraints to active constraints that affect directly the cost function manipulated directly the GA, and passive constraints such as generator bus voltages and transformer tap setting maintained in their soft limits using a conventional constraint load flow. The algorithm was developed in an Object Oriented fashion, in the C++ programming language. This option satisfies the requirements of flexibility, extensibility, maintainability and data integrity. The economic power dispatch is applied to IEEE 30-bus model system (6-generator, 41-line and 20-load). The numerical results have demonstrate the effectiveness of the stochastic search algorithms because its can provide accurate dispatch solutions with reasonable time. Further analyses indicate that this method is effective for large-scale power systems.http://journal.esrgroups.org/jes/papers/1_2_2.pdfPower flowOptimal Power FlowEnvironmental PollutionGenetic Algorithm
collection DOAJ
language English
format Article
sources DOAJ
author T. Bouktir
L. Slimani
spellingShingle T. Bouktir
L. Slimani
Object-Oriented Economic Power Dispatch of Electrical Power System with minimum pollution using a Genetic Algorithm
Journal of Electrical Systems
Power flow
Optimal Power Flow
Environmental Pollution
Genetic Algorithm
author_facet T. Bouktir
L. Slimani
author_sort T. Bouktir
title Object-Oriented Economic Power Dispatch of Electrical Power System with minimum pollution using a Genetic Algorithm
title_short Object-Oriented Economic Power Dispatch of Electrical Power System with minimum pollution using a Genetic Algorithm
title_full Object-Oriented Economic Power Dispatch of Electrical Power System with minimum pollution using a Genetic Algorithm
title_fullStr Object-Oriented Economic Power Dispatch of Electrical Power System with minimum pollution using a Genetic Algorithm
title_full_unstemmed Object-Oriented Economic Power Dispatch of Electrical Power System with minimum pollution using a Genetic Algorithm
title_sort object-oriented economic power dispatch of electrical power system with minimum pollution using a genetic algorithm
publisher ESRGroups
series Journal of Electrical Systems
issn 1112-5209
publishDate 2005-06-01
description This paper presents solution of optimal power flow (OPF) problem of electrical power system via a genetic algorithm of real type. The objective is to minimize the total fuel cost of generation and environmental pollution caused by fossil based thermal generating units and also maintain an acceptable system performance in terms of limits on generator real and reactive power outputs, bus voltages, shunt capacitors/reactors, transformers tap-setting and power flow of transmission lines. CPU times can be reduced by decomposing the optimization constraints to active constraints that affect directly the cost function manipulated directly the GA, and passive constraints such as generator bus voltages and transformer tap setting maintained in their soft limits using a conventional constraint load flow. The algorithm was developed in an Object Oriented fashion, in the C++ programming language. This option satisfies the requirements of flexibility, extensibility, maintainability and data integrity. The economic power dispatch is applied to IEEE 30-bus model system (6-generator, 41-line and 20-load). The numerical results have demonstrate the effectiveness of the stochastic search algorithms because its can provide accurate dispatch solutions with reasonable time. Further analyses indicate that this method is effective for large-scale power systems.
topic Power flow
Optimal Power Flow
Environmental Pollution
Genetic Algorithm
url http://journal.esrgroups.org/jes/papers/1_2_2.pdf
work_keys_str_mv AT tbouktir objectorientedeconomicpowerdispatchofelectricalpowersystemwithminimumpollutionusingageneticalgorithm
AT lslimani objectorientedeconomicpowerdispatchofelectricalpowersystemwithminimumpollutionusingageneticalgorithm
_version_ 1724784626313986048