Effect of Glucose Concentration on Electrochemical Corrosion Behavior of Pure Titanium TA2 in Hanks’ Simulated Body Fluid

Titanium and its alloys have been widely used as implant materials due to their excellent mechanical property and biocompatibility. In the present study, the effect of glucose concentration on corrosion behavior of pure titanium TA2 in Hanks’ simulated body fluid is investigated by the electrochemic...

Full description

Bibliographic Details
Main Authors: Shuyue Liu, Bing Wang, Peirong Zhang
Format: Article
Language:English
Published: MDPI AG 2016-10-01
Series:Materials
Subjects:
Online Access:http://www.mdpi.com/1996-1944/9/11/874
id doaj-8d634dc623f74df9855c3167e49a73d3
record_format Article
spelling doaj-8d634dc623f74df9855c3167e49a73d32020-11-24T22:15:57ZengMDPI AGMaterials1996-19442016-10-0191187410.3390/ma9110874ma9110874Effect of Glucose Concentration on Electrochemical Corrosion Behavior of Pure Titanium TA2 in Hanks’ Simulated Body FluidShuyue Liu0Bing Wang1Peirong Zhang2High School Attached to Shandong Normal University, Jinan 250014, ChinaKey Laboratory of High Efficiency and Clean Mechanical Manufacture of MOE, School of Mechanical Engineering, Shandong University, Jinan 250061, ChinaKey Laboratory of High Efficiency and Clean Mechanical Manufacture of MOE, School of Mechanical Engineering, Shandong University, Jinan 250061, ChinaTitanium and its alloys have been widely used as implant materials due to their excellent mechanical property and biocompatibility. In the present study, the effect of glucose concentration on corrosion behavior of pure titanium TA2 in Hanks’ simulated body fluid is investigated by the electrochemical impedance spectrum (EIS) and potentiodynamic polarization methods. The range of glucose concentrations investigated in this research includes 5 mmol/L (limosis for healthy people), 7 mmol/L (after diet for healthy people), 10 mmol/L (limosis for hyperglycemia patient), and 12 mmol/L (after diet for hyperglycemia patient), as well as, 15 mmol/L and 20 mmol/L, which represent different body fluid environments. The results indicate that the pure titanium TA2 demonstrates the best corrosion resistance when the glucose concentration is less than 10 mmol/L, which shows that the pure titanium TA2 as implant material can play an effective role in the body fluids with normal and slight high glucose concentrations. Comparatively, the corrosion for the pure titanium implant is more probable when the glucose concentration is over 10 mmol/L due to the premature penetration through passive film on the material surface. Corrosion defects of pitting and crevice exist on the corroded surface, and the depth of corrosion is limited to three microns with a low corrosion rate. The oxidation film on the surface of pure titanium TA2 has a protective effect on the corrosion behavior of the implant inner material. The corrosion behavior of pure titanium TA2 will happen easily once the passive film has been penetrated through. The corrosion rate for TA2 implant will accelerate quickly and a pure titanium implant cannot be used.http://www.mdpi.com/1996-1944/9/11/874glucose concentrationcorrosionpure titaniumsimulated body fluidimplant
collection DOAJ
language English
format Article
sources DOAJ
author Shuyue Liu
Bing Wang
Peirong Zhang
spellingShingle Shuyue Liu
Bing Wang
Peirong Zhang
Effect of Glucose Concentration on Electrochemical Corrosion Behavior of Pure Titanium TA2 in Hanks’ Simulated Body Fluid
Materials
glucose concentration
corrosion
pure titanium
simulated body fluid
implant
author_facet Shuyue Liu
Bing Wang
Peirong Zhang
author_sort Shuyue Liu
title Effect of Glucose Concentration on Electrochemical Corrosion Behavior of Pure Titanium TA2 in Hanks’ Simulated Body Fluid
title_short Effect of Glucose Concentration on Electrochemical Corrosion Behavior of Pure Titanium TA2 in Hanks’ Simulated Body Fluid
title_full Effect of Glucose Concentration on Electrochemical Corrosion Behavior of Pure Titanium TA2 in Hanks’ Simulated Body Fluid
title_fullStr Effect of Glucose Concentration on Electrochemical Corrosion Behavior of Pure Titanium TA2 in Hanks’ Simulated Body Fluid
title_full_unstemmed Effect of Glucose Concentration on Electrochemical Corrosion Behavior of Pure Titanium TA2 in Hanks’ Simulated Body Fluid
title_sort effect of glucose concentration on electrochemical corrosion behavior of pure titanium ta2 in hanks’ simulated body fluid
publisher MDPI AG
series Materials
issn 1996-1944
publishDate 2016-10-01
description Titanium and its alloys have been widely used as implant materials due to their excellent mechanical property and biocompatibility. In the present study, the effect of glucose concentration on corrosion behavior of pure titanium TA2 in Hanks’ simulated body fluid is investigated by the electrochemical impedance spectrum (EIS) and potentiodynamic polarization methods. The range of glucose concentrations investigated in this research includes 5 mmol/L (limosis for healthy people), 7 mmol/L (after diet for healthy people), 10 mmol/L (limosis for hyperglycemia patient), and 12 mmol/L (after diet for hyperglycemia patient), as well as, 15 mmol/L and 20 mmol/L, which represent different body fluid environments. The results indicate that the pure titanium TA2 demonstrates the best corrosion resistance when the glucose concentration is less than 10 mmol/L, which shows that the pure titanium TA2 as implant material can play an effective role in the body fluids with normal and slight high glucose concentrations. Comparatively, the corrosion for the pure titanium implant is more probable when the glucose concentration is over 10 mmol/L due to the premature penetration through passive film on the material surface. Corrosion defects of pitting and crevice exist on the corroded surface, and the depth of corrosion is limited to three microns with a low corrosion rate. The oxidation film on the surface of pure titanium TA2 has a protective effect on the corrosion behavior of the implant inner material. The corrosion behavior of pure titanium TA2 will happen easily once the passive film has been penetrated through. The corrosion rate for TA2 implant will accelerate quickly and a pure titanium implant cannot be used.
topic glucose concentration
corrosion
pure titanium
simulated body fluid
implant
url http://www.mdpi.com/1996-1944/9/11/874
work_keys_str_mv AT shuyueliu effectofglucoseconcentrationonelectrochemicalcorrosionbehaviorofpuretitaniumta2inhankssimulatedbodyfluid
AT bingwang effectofglucoseconcentrationonelectrochemicalcorrosionbehaviorofpuretitaniumta2inhankssimulatedbodyfluid
AT peirongzhang effectofglucoseconcentrationonelectrochemicalcorrosionbehaviorofpuretitaniumta2inhankssimulatedbodyfluid
_version_ 1725792013113098240