Comparison of accuracy of two uncalibrated pulse contour cardiac output monitors in off-pump coronary artery bypass surgery patients using pulmonary artery catheter-thermodilution as a reference

Abstract Background Cardiac output (CO) is a key measure of adequacy of organ and tissue perfusion, especially in critically ill or complex surgical patients. CO monitoring technology continues to evolve. Recently developed CO monitors rely on unique algorithms based on pulse contour analysis of an...

Full description

Bibliographic Details
Main Authors: Ramakrishna Mukkamala, Benjamin A. Kohl, Aman Mahajan
Format: Article
Language:English
Published: BMC 2021-07-01
Series:BMC Anesthesiology
Subjects:
Online Access:https://doi.org/10.1186/s12871-021-01415-5
id doaj-8d35e3cf6404469f9dc78dac5c0511c9
record_format Article
spelling doaj-8d35e3cf6404469f9dc78dac5c0511c92021-07-11T11:12:54ZengBMCBMC Anesthesiology1471-22532021-07-012111710.1186/s12871-021-01415-5Comparison of accuracy of two uncalibrated pulse contour cardiac output monitors in off-pump coronary artery bypass surgery patients using pulmonary artery catheter-thermodilution as a referenceRamakrishna Mukkamala0Benjamin A. Kohl1Aman Mahajan2Department of Anesthesiology and Perioperative Medicine and Department of Bioengineering, University of PittsburghDepartment of Anesthesiology, Thomas Jefferson UniversityDepartment of Anesthesiology and Perioperative Medicine and Department of Bioengineering, University of PittsburghAbstract Background Cardiac output (CO) is a key measure of adequacy of organ and tissue perfusion, especially in critically ill or complex surgical patients. CO monitoring technology continues to evolve. Recently developed CO monitors rely on unique algorithms based on pulse contour analysis of an arterial blood pressure (ABP) waveform. The objective of this investigation was to compare the accuracy of two monitors using different methods of pulse contour analysis – the Retia Argos device and the Edwards Vigileo-FloTrac device – with pulmonary artery catheter (PAC)-thermodilution as a reference. Methods Fifty-eight patients undergoing off-pump coronary artery bypass surgery formed the study cohort. A total of 572 triplets of CO measurements from each device – Argos, Vigileo-FloTrac (third generation), and thermodilution – were available before and after interventions (e.g., vasopressors, fluids, and inotropes). Bland–Altman analysis accounting for repeated measurements per subject and concordance analysis were applied to assess the accuracy of the CO values and intervention-induced CO changes of each pulse contour device against thermodilution. Cluster bootstrapping was employed to statistically compare the root-mean-squared-errors (RMSE = √(μ2 + σ2), where μ and σ are the Bland–Altman bias and precision errors) and concordance rates of the two devices. Results The RMSE (mean (95% confidence intervals)) for CO values was 1.16 (1.00–1.32) L/min for the Argos device and 1.54 (1.33–1.77) L/min for the Vigileo-FloTrac device; the concordance rate for intervention-induced CO changes was 87 (82–92)% for the Argos device and 72 (65–78)% for the Vigileo-FloTrac device; and the RMSE for the CO changes was 17 (15–19)% for the Argos device and 21 (19–23)% for the Vigileo-FloTrac device (p < 0.0167 for all comparisons). Conclusions In comparison with CO measured by the PAC, the Argos device proved to be more accurate than the Vigileo-FloTrac device in CO trending and absolute CO measurement in patients undergoing off-pump coronary artery bypass surgery.https://doi.org/10.1186/s12871-021-01415-5ArgosCardiac output monitoringFloTracPulse contour analysisThermodilution
collection DOAJ
language English
format Article
sources DOAJ
author Ramakrishna Mukkamala
Benjamin A. Kohl
Aman Mahajan
spellingShingle Ramakrishna Mukkamala
Benjamin A. Kohl
Aman Mahajan
Comparison of accuracy of two uncalibrated pulse contour cardiac output monitors in off-pump coronary artery bypass surgery patients using pulmonary artery catheter-thermodilution as a reference
BMC Anesthesiology
Argos
Cardiac output monitoring
FloTrac
Pulse contour analysis
Thermodilution
author_facet Ramakrishna Mukkamala
Benjamin A. Kohl
Aman Mahajan
author_sort Ramakrishna Mukkamala
title Comparison of accuracy of two uncalibrated pulse contour cardiac output monitors in off-pump coronary artery bypass surgery patients using pulmonary artery catheter-thermodilution as a reference
title_short Comparison of accuracy of two uncalibrated pulse contour cardiac output monitors in off-pump coronary artery bypass surgery patients using pulmonary artery catheter-thermodilution as a reference
title_full Comparison of accuracy of two uncalibrated pulse contour cardiac output monitors in off-pump coronary artery bypass surgery patients using pulmonary artery catheter-thermodilution as a reference
title_fullStr Comparison of accuracy of two uncalibrated pulse contour cardiac output monitors in off-pump coronary artery bypass surgery patients using pulmonary artery catheter-thermodilution as a reference
title_full_unstemmed Comparison of accuracy of two uncalibrated pulse contour cardiac output monitors in off-pump coronary artery bypass surgery patients using pulmonary artery catheter-thermodilution as a reference
title_sort comparison of accuracy of two uncalibrated pulse contour cardiac output monitors in off-pump coronary artery bypass surgery patients using pulmonary artery catheter-thermodilution as a reference
publisher BMC
series BMC Anesthesiology
issn 1471-2253
publishDate 2021-07-01
description Abstract Background Cardiac output (CO) is a key measure of adequacy of organ and tissue perfusion, especially in critically ill or complex surgical patients. CO monitoring technology continues to evolve. Recently developed CO monitors rely on unique algorithms based on pulse contour analysis of an arterial blood pressure (ABP) waveform. The objective of this investigation was to compare the accuracy of two monitors using different methods of pulse contour analysis – the Retia Argos device and the Edwards Vigileo-FloTrac device – with pulmonary artery catheter (PAC)-thermodilution as a reference. Methods Fifty-eight patients undergoing off-pump coronary artery bypass surgery formed the study cohort. A total of 572 triplets of CO measurements from each device – Argos, Vigileo-FloTrac (third generation), and thermodilution – were available before and after interventions (e.g., vasopressors, fluids, and inotropes). Bland–Altman analysis accounting for repeated measurements per subject and concordance analysis were applied to assess the accuracy of the CO values and intervention-induced CO changes of each pulse contour device against thermodilution. Cluster bootstrapping was employed to statistically compare the root-mean-squared-errors (RMSE = √(μ2 + σ2), where μ and σ are the Bland–Altman bias and precision errors) and concordance rates of the two devices. Results The RMSE (mean (95% confidence intervals)) for CO values was 1.16 (1.00–1.32) L/min for the Argos device and 1.54 (1.33–1.77) L/min for the Vigileo-FloTrac device; the concordance rate for intervention-induced CO changes was 87 (82–92)% for the Argos device and 72 (65–78)% for the Vigileo-FloTrac device; and the RMSE for the CO changes was 17 (15–19)% for the Argos device and 21 (19–23)% for the Vigileo-FloTrac device (p < 0.0167 for all comparisons). Conclusions In comparison with CO measured by the PAC, the Argos device proved to be more accurate than the Vigileo-FloTrac device in CO trending and absolute CO measurement in patients undergoing off-pump coronary artery bypass surgery.
topic Argos
Cardiac output monitoring
FloTrac
Pulse contour analysis
Thermodilution
url https://doi.org/10.1186/s12871-021-01415-5
work_keys_str_mv AT ramakrishnamukkamala comparisonofaccuracyoftwouncalibratedpulsecontourcardiacoutputmonitorsinoffpumpcoronaryarterybypasssurgerypatientsusingpulmonaryarterycatheterthermodilutionasareference
AT benjaminakohl comparisonofaccuracyoftwouncalibratedpulsecontourcardiacoutputmonitorsinoffpumpcoronaryarterybypasssurgerypatientsusingpulmonaryarterycatheterthermodilutionasareference
AT amanmahajan comparisonofaccuracyoftwouncalibratedpulsecontourcardiacoutputmonitorsinoffpumpcoronaryarterybypasssurgerypatientsusingpulmonaryarterycatheterthermodilutionasareference
_version_ 1721309245640540160