CALIBRATION STUDY OF A TRIMBLE ACx4 SYSTEM FOR DIRECT GEOREFERENCING MAPPING APPLICATIONS

The Trimble Aerial Camera x4 (i.e., TACx4) is a photogrammetric multi-head system manufactured by Trimble Inc.© in 2010. It has four cameras mounted together in the main structure allowing the simultaneous acquisition to generate a single synthetic image with much larger ground coverage. In...

Full description

Bibliographic Details
Main Authors: L. E. Filho, E. A. Mitishita
Format: Article
Language:English
Published: Copernicus Publications 2018-09-01
Series:ISPRS Annals of the Photogrammetry, Remote Sensing and Spatial Information Sciences
Online Access:https://www.isprs-ann-photogramm-remote-sens-spatial-inf-sci.net/IV-1/45/2018/isprs-annals-IV-1-45-2018.pdf
id doaj-8c84cba87edd428a9e4a26eb5b16b2ec
record_format Article
spelling doaj-8c84cba87edd428a9e4a26eb5b16b2ec2020-11-24T22:01:11ZengCopernicus PublicationsISPRS Annals of the Photogrammetry, Remote Sensing and Spatial Information Sciences2194-90422194-90502018-09-01IV-1455210.5194/isprs-annals-IV-1-45-2018CALIBRATION STUDY OF A TRIMBLE ACx4 SYSTEM FOR DIRECT GEOREFERENCING MAPPING APPLICATIONSL. E. Filho0E. A. Mitishita1Departamento de Geomática – DGEOM, Universidade Federal do Paraná – UFPR, 81531-990 Centro Politécnico – Curitiba/PR, BrazilDepartamento de Geomática – DGEOM, Universidade Federal do Paraná – UFPR, 81531-990 Centro Politécnico – Curitiba/PR, BrazilThe Trimble Aerial Camera x4 (i.e., TACx4) is a photogrammetric multi-head system manufactured by Trimble Inc.© in 2010. It has four cameras mounted together in the main structure allowing the simultaneous acquisition to generate a single synthetic image with much larger ground coverage. In addition, the cameras are also integrated with a GNSS/INS to perform “Direct” or “Integrated” Sensor Orientation. The main condition to obtain photogrammetric mapping products with high accuracy using a direct sensor orientation procedure is to execute a step known as “geometric system calibration”. In general, the photogrammetric multi-head system manufacturers perform this step using laboratory methods to obtain the parameters of cameras interior and relative orientation. Accurate mounting parameters (lever arms and “boresight misalignments”) are fundamental requirements to generate the synthetic image when georeferencing of images is applied. This paper shows a “full field” calibration method to perform the geometric system calibration of the TACx4 system and its evaluation for direct sensor orientation mapping applications. The developed method involves two steps using only aerial images: (1) estimation of the cameras interior and relative orientation parameters to generate the synthetic image and (2) estimation of the synthetic image interior orientation and the mounting parameters between the synthetic image and GNSS/INS reference systems using two different methods. The obtained results in the conventional photogrammetric project show that the proposed method allows performing the geometric system calibration of the TACx4 system achieving around 50 cm (5 pixels) in horizontal and vertical accuracies. The obtained results can be used for large-scale mapping requirements using direct sensor orientation according to Brazilian accuracy standards.https://www.isprs-ann-photogramm-remote-sens-spatial-inf-sci.net/IV-1/45/2018/isprs-annals-IV-1-45-2018.pdf
collection DOAJ
language English
format Article
sources DOAJ
author L. E. Filho
E. A. Mitishita
spellingShingle L. E. Filho
E. A. Mitishita
CALIBRATION STUDY OF A TRIMBLE ACx4 SYSTEM FOR DIRECT GEOREFERENCING MAPPING APPLICATIONS
ISPRS Annals of the Photogrammetry, Remote Sensing and Spatial Information Sciences
author_facet L. E. Filho
E. A. Mitishita
author_sort L. E. Filho
title CALIBRATION STUDY OF A TRIMBLE ACx4 SYSTEM FOR DIRECT GEOREFERENCING MAPPING APPLICATIONS
title_short CALIBRATION STUDY OF A TRIMBLE ACx4 SYSTEM FOR DIRECT GEOREFERENCING MAPPING APPLICATIONS
title_full CALIBRATION STUDY OF A TRIMBLE ACx4 SYSTEM FOR DIRECT GEOREFERENCING MAPPING APPLICATIONS
title_fullStr CALIBRATION STUDY OF A TRIMBLE ACx4 SYSTEM FOR DIRECT GEOREFERENCING MAPPING APPLICATIONS
title_full_unstemmed CALIBRATION STUDY OF A TRIMBLE ACx4 SYSTEM FOR DIRECT GEOREFERENCING MAPPING APPLICATIONS
title_sort calibration study of a trimble acx4 system for direct georeferencing mapping applications
publisher Copernicus Publications
series ISPRS Annals of the Photogrammetry, Remote Sensing and Spatial Information Sciences
issn 2194-9042
2194-9050
publishDate 2018-09-01
description The Trimble Aerial Camera x4 (i.e., TACx4) is a photogrammetric multi-head system manufactured by Trimble Inc.© in 2010. It has four cameras mounted together in the main structure allowing the simultaneous acquisition to generate a single synthetic image with much larger ground coverage. In addition, the cameras are also integrated with a GNSS/INS to perform “Direct” or “Integrated” Sensor Orientation. The main condition to obtain photogrammetric mapping products with high accuracy using a direct sensor orientation procedure is to execute a step known as “geometric system calibration”. In general, the photogrammetric multi-head system manufacturers perform this step using laboratory methods to obtain the parameters of cameras interior and relative orientation. Accurate mounting parameters (lever arms and “boresight misalignments”) are fundamental requirements to generate the synthetic image when georeferencing of images is applied. This paper shows a “full field” calibration method to perform the geometric system calibration of the TACx4 system and its evaluation for direct sensor orientation mapping applications. The developed method involves two steps using only aerial images: (1) estimation of the cameras interior and relative orientation parameters to generate the synthetic image and (2) estimation of the synthetic image interior orientation and the mounting parameters between the synthetic image and GNSS/INS reference systems using two different methods. The obtained results in the conventional photogrammetric project show that the proposed method allows performing the geometric system calibration of the TACx4 system achieving around 50 cm (5 pixels) in horizontal and vertical accuracies. The obtained results can be used for large-scale mapping requirements using direct sensor orientation according to Brazilian accuracy standards.
url https://www.isprs-ann-photogramm-remote-sens-spatial-inf-sci.net/IV-1/45/2018/isprs-annals-IV-1-45-2018.pdf