Fabrication of Artificial Food Bolus for Evaluation of Swallowing.

Simple and easy methods to evaluate swallowing are required because of the recently increased need of rehabilitation for dysphagia. "Artificial food bolus", but not "artificial food", would be a valuable tool for swallowing evaluation without considering the mastication effect wh...

Full description

Bibliographic Details
Main Authors: Miyu Hosotsubo, Tetsuro Magota, Masahiko Egusa, Takuya Miyawaki, Takuya Matsumoto
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2016-01-01
Series:PLoS ONE
Online Access:http://europepmc.org/articles/PMC5158057?pdf=render
id doaj-8c35383621314692bd1ea5a7995e6ad3
record_format Article
spelling doaj-8c35383621314692bd1ea5a7995e6ad32020-11-24T22:21:32ZengPublic Library of Science (PLoS)PLoS ONE1932-62032016-01-011112e016837810.1371/journal.pone.0168378Fabrication of Artificial Food Bolus for Evaluation of Swallowing.Miyu HosotsuboTetsuro MagotaMasahiko EgusaTakuya MiyawakiTakuya MatsumotoSimple and easy methods to evaluate swallowing are required because of the recently increased need of rehabilitation for dysphagia. "Artificial food bolus", but not "artificial food", would be a valuable tool for swallowing evaluation without considering the mastication effect which is altered according to the individual's oral condition. Thus, this study was carried out to fabricate artificial bolus resembling natural food bolus. The mechanical property and the volume change of food bolus in normal people were firstly investigated. Thirty healthy adults without dysphagia were selected and asked to chew four sample foods (rice cake, peanut, burdock, and gummy candy). The results indicated that Young's modulus of bolus before swallowing was below 150 kPa. The bolus volume before swallowing was below 400 mm3. In addition, the saliva component ratio of each bolus was approximately 30wt%, and the average saliva viscosity of research participants was approximately 10 mPa•s. Based on the obtained data, artificial food bolus was designed and fabricated by using alginate hydrogel as a visco-elastic material and gelatin solution as a viscotic material with a ratio of 7:3 based on weight. Consequently, the swallowing time of fabricated artificial food bolus was measured among the same participants. The results indicated the participants swallowed fabricated food bolus with similar manner reflecting their mechanical property and volume. Thus, this artificial food bolus would be a promising tool for evaluation of swallowing.http://europepmc.org/articles/PMC5158057?pdf=render
collection DOAJ
language English
format Article
sources DOAJ
author Miyu Hosotsubo
Tetsuro Magota
Masahiko Egusa
Takuya Miyawaki
Takuya Matsumoto
spellingShingle Miyu Hosotsubo
Tetsuro Magota
Masahiko Egusa
Takuya Miyawaki
Takuya Matsumoto
Fabrication of Artificial Food Bolus for Evaluation of Swallowing.
PLoS ONE
author_facet Miyu Hosotsubo
Tetsuro Magota
Masahiko Egusa
Takuya Miyawaki
Takuya Matsumoto
author_sort Miyu Hosotsubo
title Fabrication of Artificial Food Bolus for Evaluation of Swallowing.
title_short Fabrication of Artificial Food Bolus for Evaluation of Swallowing.
title_full Fabrication of Artificial Food Bolus for Evaluation of Swallowing.
title_fullStr Fabrication of Artificial Food Bolus for Evaluation of Swallowing.
title_full_unstemmed Fabrication of Artificial Food Bolus for Evaluation of Swallowing.
title_sort fabrication of artificial food bolus for evaluation of swallowing.
publisher Public Library of Science (PLoS)
series PLoS ONE
issn 1932-6203
publishDate 2016-01-01
description Simple and easy methods to evaluate swallowing are required because of the recently increased need of rehabilitation for dysphagia. "Artificial food bolus", but not "artificial food", would be a valuable tool for swallowing evaluation without considering the mastication effect which is altered according to the individual's oral condition. Thus, this study was carried out to fabricate artificial bolus resembling natural food bolus. The mechanical property and the volume change of food bolus in normal people were firstly investigated. Thirty healthy adults without dysphagia were selected and asked to chew four sample foods (rice cake, peanut, burdock, and gummy candy). The results indicated that Young's modulus of bolus before swallowing was below 150 kPa. The bolus volume before swallowing was below 400 mm3. In addition, the saliva component ratio of each bolus was approximately 30wt%, and the average saliva viscosity of research participants was approximately 10 mPa•s. Based on the obtained data, artificial food bolus was designed and fabricated by using alginate hydrogel as a visco-elastic material and gelatin solution as a viscotic material with a ratio of 7:3 based on weight. Consequently, the swallowing time of fabricated artificial food bolus was measured among the same participants. The results indicated the participants swallowed fabricated food bolus with similar manner reflecting their mechanical property and volume. Thus, this artificial food bolus would be a promising tool for evaluation of swallowing.
url http://europepmc.org/articles/PMC5158057?pdf=render
work_keys_str_mv AT miyuhosotsubo fabricationofartificialfoodbolusforevaluationofswallowing
AT tetsuromagota fabricationofartificialfoodbolusforevaluationofswallowing
AT masahikoegusa fabricationofartificialfoodbolusforevaluationofswallowing
AT takuyamiyawaki fabricationofartificialfoodbolusforevaluationofswallowing
AT takuyamatsumoto fabricationofartificialfoodbolusforevaluationofswallowing
_version_ 1725770726457212928