Infrared Turbidimetric Titration Method for Sulfate Ions in Brackish Water

In this work an infrared turbidimetric titration method is described for the determination of sulfate ions in brackish water. A suspension of barium sulfate is produced in an aqueous solution and/or brackish water sample by the addition of barium chloride solution and the turbidity is monitored wi...

Full description

Bibliographic Details
Main Authors: Benabadji Nouredine, Kherici Samira, Benouali Djillali
Format: Article
Language:English
Published: National Centre of Excellence in Analytical Chemsitry 2012-12-01
Series:Pakistan Journal of Analytical & Environmental Chemistry
Subjects:
Online Access:http://www.ceacsu.edu.pk/PDF%20file/Volume%2013%20No%202/118-122-PJAEC-25102011-09-Final.pdf
id doaj-8be4d5a9b8fe4835a8a9097097be5b1b
record_format Article
spelling doaj-8be4d5a9b8fe4835a8a9097097be5b1b2020-11-25T00:59:56ZengNational Centre of Excellence in Analytical ChemsitryPakistan Journal of Analytical & Environmental Chemistry1996-918X2221-52552012-12-011302118122Infrared Turbidimetric Titration Method for Sulfate Ions in Brackish WaterBenabadji NouredineKherici SamiraBenouali DjillaliIn this work an infrared turbidimetric titration method is described for the determination of sulfate ions in brackish water. A suspension of barium sulfate is produced in an aqueous solution and/or brackish water sample by the addition of barium chloride solution and the turbidity is monitored with the help of an immersed infrared sensor. The developed sensor utilizes an optical system to measure the evolution of turbidity during the titration. This sensor is a simple device designed in the laboratory, consisting of two infrared diodes (LED), the first is an emitter and the second is used as detector (receiver). The data acquisition system is made with the help of a dataloger made on the basis of the microcontroller 16F877/874 accompanied with adaptable software both of them are self made. Concentration over 60 µg/mL of sulfate expressed as, SO42- can be measured with high reproducibility, by this method without a preliminary treatment or dilution of the sample. The method determines SO42 - concentration of brackish water with RSD of < 1.2%.http://www.ceacsu.edu.pk/PDF%20file/Volume%2013%20No%202/118-122-PJAEC-25102011-09-Final.pdfSulfate ionInfrared sensorTurbidityTitrationEnd-point
collection DOAJ
language English
format Article
sources DOAJ
author Benabadji Nouredine
Kherici Samira
Benouali Djillali
spellingShingle Benabadji Nouredine
Kherici Samira
Benouali Djillali
Infrared Turbidimetric Titration Method for Sulfate Ions in Brackish Water
Pakistan Journal of Analytical & Environmental Chemistry
Sulfate ion
Infrared sensor
Turbidity
Titration
End-point
author_facet Benabadji Nouredine
Kherici Samira
Benouali Djillali
author_sort Benabadji Nouredine
title Infrared Turbidimetric Titration Method for Sulfate Ions in Brackish Water
title_short Infrared Turbidimetric Titration Method for Sulfate Ions in Brackish Water
title_full Infrared Turbidimetric Titration Method for Sulfate Ions in Brackish Water
title_fullStr Infrared Turbidimetric Titration Method for Sulfate Ions in Brackish Water
title_full_unstemmed Infrared Turbidimetric Titration Method for Sulfate Ions in Brackish Water
title_sort infrared turbidimetric titration method for sulfate ions in brackish water
publisher National Centre of Excellence in Analytical Chemsitry
series Pakistan Journal of Analytical & Environmental Chemistry
issn 1996-918X
2221-5255
publishDate 2012-12-01
description In this work an infrared turbidimetric titration method is described for the determination of sulfate ions in brackish water. A suspension of barium sulfate is produced in an aqueous solution and/or brackish water sample by the addition of barium chloride solution and the turbidity is monitored with the help of an immersed infrared sensor. The developed sensor utilizes an optical system to measure the evolution of turbidity during the titration. This sensor is a simple device designed in the laboratory, consisting of two infrared diodes (LED), the first is an emitter and the second is used as detector (receiver). The data acquisition system is made with the help of a dataloger made on the basis of the microcontroller 16F877/874 accompanied with adaptable software both of them are self made. Concentration over 60 µg/mL of sulfate expressed as, SO42- can be measured with high reproducibility, by this method without a preliminary treatment or dilution of the sample. The method determines SO42 - concentration of brackish water with RSD of < 1.2%.
topic Sulfate ion
Infrared sensor
Turbidity
Titration
End-point
url http://www.ceacsu.edu.pk/PDF%20file/Volume%2013%20No%202/118-122-PJAEC-25102011-09-Final.pdf
work_keys_str_mv AT benabadjinouredine infraredturbidimetrictitrationmethodforsulfateionsinbrackishwater
AT khericisamira infraredturbidimetrictitrationmethodforsulfateionsinbrackishwater
AT benoualidjillali infraredturbidimetrictitrationmethodforsulfateionsinbrackishwater
_version_ 1725215276721504256