Optimization of calculations of the effects of spill fires during accidents on linear equipment

The issue of industrial (in particular, fire) safety at hazardous production facilities is considered. The previously obtained optimization method is given for calculating the assessment of the influence of hazardous factors in the event of possible accidents on extended (linear) equipment during ex...

Full description

Bibliographic Details
Main Authors: Saltanaeva Elena Andreevna, Maister Andrey Vladimirovich
Format: Article
Language:English
Published: EDP Sciences 2019-01-01
Series:E3S Web of Conferences
Online Access:https://www.e3s-conferences.org/articles/e3sconf/pdf/2019/66/e3sconf_eece18_07002.pdf
id doaj-8be48d1f86784d47b0998726a984b2ca
record_format Article
spelling doaj-8be48d1f86784d47b0998726a984b2ca2021-02-02T08:13:48ZengEDP SciencesE3S Web of Conferences2267-12422019-01-011400700210.1051/e3sconf/201914007002e3sconf_eece18_07002Optimization of calculations of the effects of spill fires during accidents on linear equipmentSaltanaeva Elena Andreevna0Maister Andrey Vladimirovich1Kazan State Energy UniversityKazan State Energy UniversityThe issue of industrial (in particular, fire) safety at hazardous production facilities is considered. The previously obtained optimization method is given for calculating the assessment of the influence of hazardous factors in the event of possible accidents on extended (linear) equipment during explosions of fuel-air mixtures. Optimization is based on accelerating the calculations of the potential damage probability of Qn(M0) using transformed formulas containing a single instead of a double integral. The transformed formulas for calculating the double integral obtained in were used to optimize the calculations for the case of a spill fire based on the recommended probit function Pr used to estimate the damage to people by thermal radiation. As an example of calculations, a rectilinear fragment of a pipeline on a plane, presented as a segment of a straight line, is considered. To obtain an assessment of effectiveness, 1000 sets of source data characterizing various emergency situations were randomly generated. Based on the calculations for these data sets, statistical results are presented that characterize the effectiveness of the proposed optimization method: a graph of the values of the multiplicity of the reduction in calculation time using the converted formulas; average value and standard deviation of the multiplicity of reduction of calculation time; the maximum deviation of the values calculated by the original and converted formulas.https://www.e3s-conferences.org/articles/e3sconf/pdf/2019/66/e3sconf_eece18_07002.pdf
collection DOAJ
language English
format Article
sources DOAJ
author Saltanaeva Elena Andreevna
Maister Andrey Vladimirovich
spellingShingle Saltanaeva Elena Andreevna
Maister Andrey Vladimirovich
Optimization of calculations of the effects of spill fires during accidents on linear equipment
E3S Web of Conferences
author_facet Saltanaeva Elena Andreevna
Maister Andrey Vladimirovich
author_sort Saltanaeva Elena Andreevna
title Optimization of calculations of the effects of spill fires during accidents on linear equipment
title_short Optimization of calculations of the effects of spill fires during accidents on linear equipment
title_full Optimization of calculations of the effects of spill fires during accidents on linear equipment
title_fullStr Optimization of calculations of the effects of spill fires during accidents on linear equipment
title_full_unstemmed Optimization of calculations of the effects of spill fires during accidents on linear equipment
title_sort optimization of calculations of the effects of spill fires during accidents on linear equipment
publisher EDP Sciences
series E3S Web of Conferences
issn 2267-1242
publishDate 2019-01-01
description The issue of industrial (in particular, fire) safety at hazardous production facilities is considered. The previously obtained optimization method is given for calculating the assessment of the influence of hazardous factors in the event of possible accidents on extended (linear) equipment during explosions of fuel-air mixtures. Optimization is based on accelerating the calculations of the potential damage probability of Qn(M0) using transformed formulas containing a single instead of a double integral. The transformed formulas for calculating the double integral obtained in were used to optimize the calculations for the case of a spill fire based on the recommended probit function Pr used to estimate the damage to people by thermal radiation. As an example of calculations, a rectilinear fragment of a pipeline on a plane, presented as a segment of a straight line, is considered. To obtain an assessment of effectiveness, 1000 sets of source data characterizing various emergency situations were randomly generated. Based on the calculations for these data sets, statistical results are presented that characterize the effectiveness of the proposed optimization method: a graph of the values of the multiplicity of the reduction in calculation time using the converted formulas; average value and standard deviation of the multiplicity of reduction of calculation time; the maximum deviation of the values calculated by the original and converted formulas.
url https://www.e3s-conferences.org/articles/e3sconf/pdf/2019/66/e3sconf_eece18_07002.pdf
work_keys_str_mv AT saltanaevaelenaandreevna optimizationofcalculationsoftheeffectsofspillfiresduringaccidentsonlinearequipment
AT maisterandreyvladimirovich optimizationofcalculationsoftheeffectsofspillfiresduringaccidentsonlinearequipment
_version_ 1724297601763770368