Current interference of HVDC ground electrode to buried pipelines and its personal safety distance

When DC ground electrode of a high-voltage direct current (HVDC) transmission system is in the stage of early operation or in the case of failures and maintenance, an instantaneous large current will be generated and bring great potential safety hazards to the nearby buried oil/gas pipelines and fac...

Full description

Bibliographic Details
Main Authors: Guofei Cao, Qinglin Gu, Yongtao Jiang, Yongfa Li, Jian Mao, Linran Xiu, Xiuyun Wang, Zitao Jiang
Format: Article
Language:English
Published: KeAi Communications Co., Ltd. 2019-10-01
Series:Natural Gas Industry B
Online Access:http://www.sciencedirect.com/science/article/pii/S2352854019300865
id doaj-8b5b2142f551465580a577bd7a22bacc
record_format Article
spelling doaj-8b5b2142f551465580a577bd7a22bacc2021-04-02T13:34:35ZengKeAi Communications Co., Ltd.Natural Gas Industry B2352-85402019-10-0165427434Current interference of HVDC ground electrode to buried pipelines and its personal safety distanceGuofei Cao0Qinglin Gu1Yongtao Jiang2Yongfa Li3Jian Mao4Linran Xiu5Xiuyun Wang6Zitao Jiang7West–East Gas Pipeline Branch, PetroChina Pipeline Company, Shanghai 200135, ChinaWest–East Gas Pipeline Branch, PetroChina Pipeline Company, Shanghai 200135, ChinaWest–East Gas Pipeline Branch, PetroChina Pipeline Company, Shanghai 200135, ChinaSafetech Research Institute, Beijing 100083, China; Corresponding author.West–East Gas Pipeline Branch, PetroChina Pipeline Company, Shanghai 200135, ChinaWest–East Gas Pipeline Branch, PetroChina Pipeline Company, Shanghai 200135, ChinaSafetech Research Institute, Beijing 100083, ChinaSafetech Research Institute, Beijing 100083, ChinaWhen DC ground electrode of a high-voltage direct current (HVDC) transmission system is in the stage of early operation or in the case of failures and maintenance, an instantaneous large current will be generated and bring great potential safety hazards to the nearby buried oil/gas pipelines and facilities and operators. In order to ensure the safety of persons near the buried pipelines, we investigated the current interference of the HVDC ground electrode to buried pipelines and its personal safety distance (hereinafter referred to as a safety distance). Firstly, the model simulating the electromagnetic interference to buried pipelines was established by means of the numerical simulation technology. Then, the model was used to calculate the safety distance corresponding to eddy current interference of HVDC ground electrode to buried pipelines under different soil resistivities, pipeline lengths, pipeline anti-corrosion insulations, earth currents of ground electrode and pipeline sizes. Finally, the influence laws of above-mentioned factors on the interference degree of HVDC ground electrode were analyzed. And the following research results were obtained. First, the influence of pipeline length on the interference degree of interference of the HVDC ground electrode is great. The longer the pipeline, the greater the safety distance. When the pipeline is equal to or longer than 600 km, however, the safety distance is basically the same. Second, the effect of pipeline coating on the interference degree of HVDC ground electrode is great. As the coating surface resistivity increases, the safety distance increases gradually. Third, for multi-layer soil structures, the maximum single-layer resistivity can be taken as the overall resistivity. And correspondingly, the calculated safety distance obtained is the longest, and the evaluation result is more conservative. In conclusion, the safety distance diagrams of the pipelines with 4 lengths which are obtained based on the calculation results can be used as reference in the design of HVDC ground electrodes and pipelines, as well as the basis for selecting the safety distance of HVDC ground electrode or buried pipeline to be constructed. Keywords: HVDC ground electrode, Personal safety distance, Buried pipeline, Numerical simulation, Electromagnetic interference, Pipeline length, Soil resistivity, Coating surface resistivityhttp://www.sciencedirect.com/science/article/pii/S2352854019300865
collection DOAJ
language English
format Article
sources DOAJ
author Guofei Cao
Qinglin Gu
Yongtao Jiang
Yongfa Li
Jian Mao
Linran Xiu
Xiuyun Wang
Zitao Jiang
spellingShingle Guofei Cao
Qinglin Gu
Yongtao Jiang
Yongfa Li
Jian Mao
Linran Xiu
Xiuyun Wang
Zitao Jiang
Current interference of HVDC ground electrode to buried pipelines and its personal safety distance
Natural Gas Industry B
author_facet Guofei Cao
Qinglin Gu
Yongtao Jiang
Yongfa Li
Jian Mao
Linran Xiu
Xiuyun Wang
Zitao Jiang
author_sort Guofei Cao
title Current interference of HVDC ground electrode to buried pipelines and its personal safety distance
title_short Current interference of HVDC ground electrode to buried pipelines and its personal safety distance
title_full Current interference of HVDC ground electrode to buried pipelines and its personal safety distance
title_fullStr Current interference of HVDC ground electrode to buried pipelines and its personal safety distance
title_full_unstemmed Current interference of HVDC ground electrode to buried pipelines and its personal safety distance
title_sort current interference of hvdc ground electrode to buried pipelines and its personal safety distance
publisher KeAi Communications Co., Ltd.
series Natural Gas Industry B
issn 2352-8540
publishDate 2019-10-01
description When DC ground electrode of a high-voltage direct current (HVDC) transmission system is in the stage of early operation or in the case of failures and maintenance, an instantaneous large current will be generated and bring great potential safety hazards to the nearby buried oil/gas pipelines and facilities and operators. In order to ensure the safety of persons near the buried pipelines, we investigated the current interference of the HVDC ground electrode to buried pipelines and its personal safety distance (hereinafter referred to as a safety distance). Firstly, the model simulating the electromagnetic interference to buried pipelines was established by means of the numerical simulation technology. Then, the model was used to calculate the safety distance corresponding to eddy current interference of HVDC ground electrode to buried pipelines under different soil resistivities, pipeline lengths, pipeline anti-corrosion insulations, earth currents of ground electrode and pipeline sizes. Finally, the influence laws of above-mentioned factors on the interference degree of HVDC ground electrode were analyzed. And the following research results were obtained. First, the influence of pipeline length on the interference degree of interference of the HVDC ground electrode is great. The longer the pipeline, the greater the safety distance. When the pipeline is equal to or longer than 600 km, however, the safety distance is basically the same. Second, the effect of pipeline coating on the interference degree of HVDC ground electrode is great. As the coating surface resistivity increases, the safety distance increases gradually. Third, for multi-layer soil structures, the maximum single-layer resistivity can be taken as the overall resistivity. And correspondingly, the calculated safety distance obtained is the longest, and the evaluation result is more conservative. In conclusion, the safety distance diagrams of the pipelines with 4 lengths which are obtained based on the calculation results can be used as reference in the design of HVDC ground electrodes and pipelines, as well as the basis for selecting the safety distance of HVDC ground electrode or buried pipeline to be constructed. Keywords: HVDC ground electrode, Personal safety distance, Buried pipeline, Numerical simulation, Electromagnetic interference, Pipeline length, Soil resistivity, Coating surface resistivity
url http://www.sciencedirect.com/science/article/pii/S2352854019300865
work_keys_str_mv AT guofeicao currentinterferenceofhvdcgroundelectrodetoburiedpipelinesanditspersonalsafetydistance
AT qinglingu currentinterferenceofhvdcgroundelectrodetoburiedpipelinesanditspersonalsafetydistance
AT yongtaojiang currentinterferenceofhvdcgroundelectrodetoburiedpipelinesanditspersonalsafetydistance
AT yongfali currentinterferenceofhvdcgroundelectrodetoburiedpipelinesanditspersonalsafetydistance
AT jianmao currentinterferenceofhvdcgroundelectrodetoburiedpipelinesanditspersonalsafetydistance
AT linranxiu currentinterferenceofhvdcgroundelectrodetoburiedpipelinesanditspersonalsafetydistance
AT xiuyunwang currentinterferenceofhvdcgroundelectrodetoburiedpipelinesanditspersonalsafetydistance
AT zitaojiang currentinterferenceofhvdcgroundelectrodetoburiedpipelinesanditspersonalsafetydistance
_version_ 1721564493631193088