On the precise measurement capability of the direct microscopic measurement method for wear volume characterization

There are plenty of methods for determining the wear volume after a wear test. Due to the geometrical assumptions, some of them could unfortunately lead to mistaken results. It has been shown that a novel method, the direct microscopic measurement, is able to calculate the wear volume on a specimen...

Full description

Bibliographic Details
Main Author: Türedi Enbiya
Format: Article
Language:English
Published: EDP Sciences 2018-01-01
Series:MATEC Web of Conferences
Online Access:https://doi.org/10.1051/matecconf/201818802007
id doaj-8b514b880963461184d6c95f29845a48
record_format Article
spelling doaj-8b514b880963461184d6c95f29845a482021-02-02T00:41:44ZengEDP SciencesMATEC Web of Conferences2261-236X2018-01-011880200710.1051/matecconf/201818802007matecconf_iceaf-v2018_02007On the precise measurement capability of the direct microscopic measurement method for wear volume characterizationTüredi EnbiyaThere are plenty of methods for determining the wear volume after a wear test. Due to the geometrical assumptions, some of them could unfortunately lead to mistaken results. It has been shown that a novel method, the direct microscopic measurement, is able to calculate the wear volume on a specimen surface very precisely and accurately [1-2]. It is based on creating a series of line profiles perpendicular to the wear scar. This novel method, however, needs to be characterized in terms of measurement limitations and minimum detectable volume capability. For example, how small or how shallow a wear scar could be calculated or measured with this method, must be determined. For this purpose, it has been prepared a series of wear test specimens exposed to the different amounts of wear in a “pin-on-disk” type test rig. As specimens, two different non-ferrous mold materials, Al bronze alloys, were selected and prepared metallographically. Counterpart materials were inox steel and bearing steel balls with diameter of 6 mm. Normal load was set to 5 N. Test configurations were set to 1, 5, 10 and 100 m of sliding distance values, in turn. Wear tests were conducted in according to ASTM G99 standard. Wear volume results were determined both direct microscopic measurement and also a 3D optical microscope methods. Comparison results showed that the novel method could be successfully used for wear volume calculations even with small amounts of wear volume conditions.https://doi.org/10.1051/matecconf/201818802007
collection DOAJ
language English
format Article
sources DOAJ
author Türedi Enbiya
spellingShingle Türedi Enbiya
On the precise measurement capability of the direct microscopic measurement method for wear volume characterization
MATEC Web of Conferences
author_facet Türedi Enbiya
author_sort Türedi Enbiya
title On the precise measurement capability of the direct microscopic measurement method for wear volume characterization
title_short On the precise measurement capability of the direct microscopic measurement method for wear volume characterization
title_full On the precise measurement capability of the direct microscopic measurement method for wear volume characterization
title_fullStr On the precise measurement capability of the direct microscopic measurement method for wear volume characterization
title_full_unstemmed On the precise measurement capability of the direct microscopic measurement method for wear volume characterization
title_sort on the precise measurement capability of the direct microscopic measurement method for wear volume characterization
publisher EDP Sciences
series MATEC Web of Conferences
issn 2261-236X
publishDate 2018-01-01
description There are plenty of methods for determining the wear volume after a wear test. Due to the geometrical assumptions, some of them could unfortunately lead to mistaken results. It has been shown that a novel method, the direct microscopic measurement, is able to calculate the wear volume on a specimen surface very precisely and accurately [1-2]. It is based on creating a series of line profiles perpendicular to the wear scar. This novel method, however, needs to be characterized in terms of measurement limitations and minimum detectable volume capability. For example, how small or how shallow a wear scar could be calculated or measured with this method, must be determined. For this purpose, it has been prepared a series of wear test specimens exposed to the different amounts of wear in a “pin-on-disk” type test rig. As specimens, two different non-ferrous mold materials, Al bronze alloys, were selected and prepared metallographically. Counterpart materials were inox steel and bearing steel balls with diameter of 6 mm. Normal load was set to 5 N. Test configurations were set to 1, 5, 10 and 100 m of sliding distance values, in turn. Wear tests were conducted in according to ASTM G99 standard. Wear volume results were determined both direct microscopic measurement and also a 3D optical microscope methods. Comparison results showed that the novel method could be successfully used for wear volume calculations even with small amounts of wear volume conditions.
url https://doi.org/10.1051/matecconf/201818802007
work_keys_str_mv AT turedienbiya ontheprecisemeasurementcapabilityofthedirectmicroscopicmeasurementmethodforwearvolumecharacterization
_version_ 1724313276275228672