Fifty years of balloon-borne ozone profile measurements at Uccle, Belgium: a short history, the scientific relevance, and the achievements in understanding the vertical ozone distribution
<p>Starting in 1969 and comprising three launches a week, the Uccle (Brussels, Belgium) ozonesonde dataset is one of longest and densest in the world. Moreover, as the only major change was the switch from Brewer-Mast (BM) to electrochemical concentration cell (ECC) ozonesonde types in 1997 (w...
Main Authors: | , , , , , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Copernicus Publications
2021-08-01
|
Series: | Atmospheric Chemistry and Physics |
Online Access: | https://acp.copernicus.org/articles/21/12385/2021/acp-21-12385-2021.pdf |
id |
doaj-8b053aede973423fb7a01d66c6f9e864 |
---|---|
record_format |
Article |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
R. Van Malderen D. De Muer H. De Backer D. Poyraz W. W. Verstraeten V. De Bock A. W. Delcloo A. Mangold Q. Laffineur M. Allaart F. Fierens V. Thouret |
spellingShingle |
R. Van Malderen D. De Muer H. De Backer D. Poyraz W. W. Verstraeten V. De Bock A. W. Delcloo A. Mangold Q. Laffineur M. Allaart F. Fierens V. Thouret Fifty years of balloon-borne ozone profile measurements at Uccle, Belgium: a short history, the scientific relevance, and the achievements in understanding the vertical ozone distribution Atmospheric Chemistry and Physics |
author_facet |
R. Van Malderen D. De Muer H. De Backer D. Poyraz W. W. Verstraeten V. De Bock A. W. Delcloo A. Mangold Q. Laffineur M. Allaart F. Fierens V. Thouret |
author_sort |
R. Van Malderen |
title |
Fifty years of balloon-borne ozone profile measurements at Uccle, Belgium: a short history, the scientific relevance, and the achievements in understanding the vertical ozone distribution |
title_short |
Fifty years of balloon-borne ozone profile measurements at Uccle, Belgium: a short history, the scientific relevance, and the achievements in understanding the vertical ozone distribution |
title_full |
Fifty years of balloon-borne ozone profile measurements at Uccle, Belgium: a short history, the scientific relevance, and the achievements in understanding the vertical ozone distribution |
title_fullStr |
Fifty years of balloon-borne ozone profile measurements at Uccle, Belgium: a short history, the scientific relevance, and the achievements in understanding the vertical ozone distribution |
title_full_unstemmed |
Fifty years of balloon-borne ozone profile measurements at Uccle, Belgium: a short history, the scientific relevance, and the achievements in understanding the vertical ozone distribution |
title_sort |
fifty years of balloon-borne ozone profile measurements at uccle, belgium: a short history, the scientific relevance, and the achievements in understanding the vertical ozone distribution |
publisher |
Copernicus Publications |
series |
Atmospheric Chemistry and Physics |
issn |
1680-7316 1680-7324 |
publishDate |
2021-08-01 |
description |
<p>Starting in 1969 and comprising three launches a week, the
Uccle (Brussels, Belgium) ozonesonde dataset is one of longest and densest
in the world. Moreover, as the only major change was the switch from
Brewer-Mast (BM) to electrochemical concentration cell (ECC) ozonesonde
types in 1997 (when the emissions of ozone-depleting substances peaked), the Uccle time series is very homogenous. In this paper, we briefly describe the efforts that were undertaken during the first 3 decades of the 50 years
of ozonesonde observations to guarantee the homogeneity between ascent and
descent profiles, under changing environmental conditions (e.g. SO<span class="inline-formula"><sub>2</sub></span>),
and between the different ozonesonde types. This paper focuses on the 50-year-long Uccle ozonesonde dataset and aims to demonstrate its past,
present, and future relevance to ozone research in two application areas: (i) the assessment of the temporal evolution of ozone from the surface to the
(middle) stratosphere, and (ii) as the backbone for validation and stability
analysis of both stratospheric and tropospheric satellite ozone
retrievals. Using the Long-term Ozone Trends and Uncertainties in the
Stratosphere (LOTUS) multiple linear regression model (SPARC/IO3C/GAW,
2019), we found that the stratospheric ozone concentrations at Uccle
have declined at a significant rate of around 2 % per decade since 1969, which is also rather
consistent over the different stratospheric levels. This overall decrease
can mainly be assigned to the 1969–1996 period with a rather consistent
rate of decrease of around <span class="inline-formula">−</span>4 % per decade. Since 2000, a recovery of between <span class="inline-formula">+</span>1 % per decade and <span class="inline-formula">+</span>3 % per decade of the stratospheric ozone levels above Uccle has been
observed, although it is not significant and is not seen for the upper stratospheric
levels measured by ozonesondes. Throughout the entire free troposphere, a
very consistent increase in the ozone concentrations of 2 % per decade to 3 % per decade has been measured since both 1969 and 1995, with the trend since 1995 being in
almost perfect agreement with the trends derived from the In-service
Aircraft for a Global Observing System (IAGOS) ascent/descent profiles at
Frankfurt. As the number of tropopause folding events in the Uccle time
series has increased significantly over time, increased
stratosphere-to-troposphere transport of recovering stratospheric ozone
might partly explain these increasing tropospheric ozone concentrations,
despite the levelling-off of (tropospheric) ozone precursor emissions and
notwithstanding the continued increase in mean surface ozone concentrations.
Furthermore, we illustrate the crucial role of ozonesonde measurements for
the validation of satellite ozone profile retrievals. With the operational
validation of the Global Ozone Monitoring Experiment-2 (GOME-2), we show how the
Uccle dataset can be used to evaluate the performance of a degradation
correction for the MetOp-A/GOME-2 UV (ultraviolet) sensors. In another example, we
illustrate that the Microwave Limb Sounder (MLS) overpass ozone profiles in
the stratosphere agree within <span class="inline-formula">±</span>5 % with the Uccle ozone profiles
between 10 and 70 hPa. Another instrument on the same Aura<span id="page12386"/> satellite
platform, the Tropospheric Emission Spectrometer (TES), is generally positively
biased with respect to the Uccle ozonesondes in the troposphere by up to
<span class="inline-formula">∼</span> 10 ppbv, corresponding to relative differences of up to
<span class="inline-formula">∼</span> 15 %. Using the Uccle ozonesonde time series as a
reference, we also demonstrate that the temporal stability of those last two satellite retrievals is excellent.</p> |
url |
https://acp.copernicus.org/articles/21/12385/2021/acp-21-12385-2021.pdf |
work_keys_str_mv |
AT rvanmalderen fiftyyearsofballoonborneozoneprofilemeasurementsatucclebelgiumashorthistorythescientificrelevanceandtheachievementsinunderstandingtheverticalozonedistribution AT ddemuer fiftyyearsofballoonborneozoneprofilemeasurementsatucclebelgiumashorthistorythescientificrelevanceandtheachievementsinunderstandingtheverticalozonedistribution AT hdebacker fiftyyearsofballoonborneozoneprofilemeasurementsatucclebelgiumashorthistorythescientificrelevanceandtheachievementsinunderstandingtheverticalozonedistribution AT dpoyraz fiftyyearsofballoonborneozoneprofilemeasurementsatucclebelgiumashorthistorythescientificrelevanceandtheachievementsinunderstandingtheverticalozonedistribution AT wwverstraeten fiftyyearsofballoonborneozoneprofilemeasurementsatucclebelgiumashorthistorythescientificrelevanceandtheachievementsinunderstandingtheverticalozonedistribution AT vdebock fiftyyearsofballoonborneozoneprofilemeasurementsatucclebelgiumashorthistorythescientificrelevanceandtheachievementsinunderstandingtheverticalozonedistribution AT awdelcloo fiftyyearsofballoonborneozoneprofilemeasurementsatucclebelgiumashorthistorythescientificrelevanceandtheachievementsinunderstandingtheverticalozonedistribution AT amangold fiftyyearsofballoonborneozoneprofilemeasurementsatucclebelgiumashorthistorythescientificrelevanceandtheachievementsinunderstandingtheverticalozonedistribution AT qlaffineur fiftyyearsofballoonborneozoneprofilemeasurementsatucclebelgiumashorthistorythescientificrelevanceandtheachievementsinunderstandingtheverticalozonedistribution AT mallaart fiftyyearsofballoonborneozoneprofilemeasurementsatucclebelgiumashorthistorythescientificrelevanceandtheachievementsinunderstandingtheverticalozonedistribution AT ffierens fiftyyearsofballoonborneozoneprofilemeasurementsatucclebelgiumashorthistorythescientificrelevanceandtheachievementsinunderstandingtheverticalozonedistribution AT vthouret fiftyyearsofballoonborneozoneprofilemeasurementsatucclebelgiumashorthistorythescientificrelevanceandtheachievementsinunderstandingtheverticalozonedistribution |
_version_ |
1721203324108144640 |
spelling |
doaj-8b053aede973423fb7a01d66c6f9e8642021-08-18T09:48:07ZengCopernicus PublicationsAtmospheric Chemistry and Physics1680-73161680-73242021-08-0121123851241110.5194/acp-21-12385-2021Fifty years of balloon-borne ozone profile measurements at Uccle, Belgium: a short history, the scientific relevance, and the achievements in understanding the vertical ozone distributionR. Van Malderen0D. De Muer1H. De Backer2D. Poyraz3W. W. Verstraeten4V. De Bock5A. W. Delcloo6A. Mangold7Q. Laffineur8M. Allaart9F. Fierens10V. Thouret11Scientific Division Observations, Royal Meteorological Institute of Belgium, 1180 Uccle (Brussels), BelgiumScientific Division Observations, Royal Meteorological Institute of Belgium, 1180 Uccle (Brussels), BelgiumScientific Division Observations, Royal Meteorological Institute of Belgium, 1180 Uccle (Brussels), BelgiumScientific Division Observations, Royal Meteorological Institute of Belgium, 1180 Uccle (Brussels), BelgiumScientific Division Observations, Royal Meteorological Institute of Belgium, 1180 Uccle (Brussels), BelgiumScientific Division Observations, Royal Meteorological Institute of Belgium, 1180 Uccle (Brussels), BelgiumScientific Division Observations, Royal Meteorological Institute of Belgium, 1180 Uccle (Brussels), BelgiumScientific Division Observations, Royal Meteorological Institute of Belgium, 1180 Uccle (Brussels), BelgiumScientific Division Observations, Royal Meteorological Institute of Belgium, 1180 Uccle (Brussels), BelgiumResearch and Development of Satellite Observations, KNMI, 3730 AE De Bilt, the NetherlandsBelgian Interregional Environment Agency (IRCEL – CELINE), 1030 Brussels, BelgiumLaboratoire d'Aérologie, Université de Toulouse, CNRS, UPS, 31400 Toulouse, France<p>Starting in 1969 and comprising three launches a week, the Uccle (Brussels, Belgium) ozonesonde dataset is one of longest and densest in the world. Moreover, as the only major change was the switch from Brewer-Mast (BM) to electrochemical concentration cell (ECC) ozonesonde types in 1997 (when the emissions of ozone-depleting substances peaked), the Uccle time series is very homogenous. In this paper, we briefly describe the efforts that were undertaken during the first 3 decades of the 50 years of ozonesonde observations to guarantee the homogeneity between ascent and descent profiles, under changing environmental conditions (e.g. SO<span class="inline-formula"><sub>2</sub></span>), and between the different ozonesonde types. This paper focuses on the 50-year-long Uccle ozonesonde dataset and aims to demonstrate its past, present, and future relevance to ozone research in two application areas: (i) the assessment of the temporal evolution of ozone from the surface to the (middle) stratosphere, and (ii) as the backbone for validation and stability analysis of both stratospheric and tropospheric satellite ozone retrievals. Using the Long-term Ozone Trends and Uncertainties in the Stratosphere (LOTUS) multiple linear regression model (SPARC/IO3C/GAW, 2019), we found that the stratospheric ozone concentrations at Uccle have declined at a significant rate of around 2 % per decade since 1969, which is also rather consistent over the different stratospheric levels. This overall decrease can mainly be assigned to the 1969–1996 period with a rather consistent rate of decrease of around <span class="inline-formula">−</span>4 % per decade. Since 2000, a recovery of between <span class="inline-formula">+</span>1 % per decade and <span class="inline-formula">+</span>3 % per decade of the stratospheric ozone levels above Uccle has been observed, although it is not significant and is not seen for the upper stratospheric levels measured by ozonesondes. Throughout the entire free troposphere, a very consistent increase in the ozone concentrations of 2 % per decade to 3 % per decade has been measured since both 1969 and 1995, with the trend since 1995 being in almost perfect agreement with the trends derived from the In-service Aircraft for a Global Observing System (IAGOS) ascent/descent profiles at Frankfurt. As the number of tropopause folding events in the Uccle time series has increased significantly over time, increased stratosphere-to-troposphere transport of recovering stratospheric ozone might partly explain these increasing tropospheric ozone concentrations, despite the levelling-off of (tropospheric) ozone precursor emissions and notwithstanding the continued increase in mean surface ozone concentrations. Furthermore, we illustrate the crucial role of ozonesonde measurements for the validation of satellite ozone profile retrievals. With the operational validation of the Global Ozone Monitoring Experiment-2 (GOME-2), we show how the Uccle dataset can be used to evaluate the performance of a degradation correction for the MetOp-A/GOME-2 UV (ultraviolet) sensors. In another example, we illustrate that the Microwave Limb Sounder (MLS) overpass ozone profiles in the stratosphere agree within <span class="inline-formula">±</span>5 % with the Uccle ozone profiles between 10 and 70 hPa. Another instrument on the same Aura<span id="page12386"/> satellite platform, the Tropospheric Emission Spectrometer (TES), is generally positively biased with respect to the Uccle ozonesondes in the troposphere by up to <span class="inline-formula">∼</span> 10 ppbv, corresponding to relative differences of up to <span class="inline-formula">∼</span> 15 %. Using the Uccle ozonesonde time series as a reference, we also demonstrate that the temporal stability of those last two satellite retrievals is excellent.</p>https://acp.copernicus.org/articles/21/12385/2021/acp-21-12385-2021.pdf |