A remote test method for power grid security and stability control system and its engineering application

Security and stability control (SSC) system or special protection system (SPS) is an important means to ensure the safe operation of power grid. In view of the insufficiency that the current open-loop testing method cannot fully test the SSC system on-site, a remote real-time closed-loop test method...

Full description

Bibliographic Details
Main Authors: Guo Qi, Zhu Yihua, Chang Dongxu, Li Shengnan, Chen Yong, Wu Mingkang
Format: Article
Language:English
Published: EDP Sciences 2021-01-01
Series:E3S Web of Conferences
Subjects:
Online Access:https://www.e3s-conferences.org/articles/e3sconf/pdf/2021/36/e3sconf_aepee2021_02006.pdf
id doaj-8aff741d334846ab9668e84eb83312f4
record_format Article
spelling doaj-8aff741d334846ab9668e84eb83312f42021-05-28T14:41:16ZengEDP SciencesE3S Web of Conferences2267-12422021-01-012600200610.1051/e3sconf/202126002006e3sconf_aepee2021_02006A remote test method for power grid security and stability control system and its engineering applicationGuo QiZhu YihuaChang DongxuLi Shengnan0Chen Yong1Wu MingkangElectric Power Research Institute, Ltd. of Yunnan Power Grid Co.Electric Power Research Institute, Ltd. of Yunnan Power Grid Co.Security and stability control (SSC) system or special protection system (SPS) is an important means to ensure the safe operation of power grid. In view of the insufficiency that the current open-loop testing method cannot fully test the SSC system on-site, a remote real-time closed-loop test method is proposed. The solutions of key techniques such as information interaction, remote communication and signal conversion in remote test system are studied. Then the platform architecture and standard interface of the remote test system are designed. A remote test platform for SSC system is developed, and there application modes of the platform is deeply analysed. Finally, taking SSC system of Yunnan AC power outgoing grid as pilot application, experiment of two substations on-site is carried out. The results in practical project further prove the effectiveness of the method presented in this paper.https://www.e3s-conferences.org/articles/e3sconf/pdf/2021/36/e3sconf_aepee2021_02006.pdfsecurity and stability control systemreal-time simulationpower communication networkremote closed loop test
collection DOAJ
language English
format Article
sources DOAJ
author Guo Qi
Zhu Yihua
Chang Dongxu
Li Shengnan
Chen Yong
Wu Mingkang
spellingShingle Guo Qi
Zhu Yihua
Chang Dongxu
Li Shengnan
Chen Yong
Wu Mingkang
A remote test method for power grid security and stability control system and its engineering application
E3S Web of Conferences
security and stability control system
real-time simulation
power communication network
remote closed loop test
author_facet Guo Qi
Zhu Yihua
Chang Dongxu
Li Shengnan
Chen Yong
Wu Mingkang
author_sort Guo Qi
title A remote test method for power grid security and stability control system and its engineering application
title_short A remote test method for power grid security and stability control system and its engineering application
title_full A remote test method for power grid security and stability control system and its engineering application
title_fullStr A remote test method for power grid security and stability control system and its engineering application
title_full_unstemmed A remote test method for power grid security and stability control system and its engineering application
title_sort remote test method for power grid security and stability control system and its engineering application
publisher EDP Sciences
series E3S Web of Conferences
issn 2267-1242
publishDate 2021-01-01
description Security and stability control (SSC) system or special protection system (SPS) is an important means to ensure the safe operation of power grid. In view of the insufficiency that the current open-loop testing method cannot fully test the SSC system on-site, a remote real-time closed-loop test method is proposed. The solutions of key techniques such as information interaction, remote communication and signal conversion in remote test system are studied. Then the platform architecture and standard interface of the remote test system are designed. A remote test platform for SSC system is developed, and there application modes of the platform is deeply analysed. Finally, taking SSC system of Yunnan AC power outgoing grid as pilot application, experiment of two substations on-site is carried out. The results in practical project further prove the effectiveness of the method presented in this paper.
topic security and stability control system
real-time simulation
power communication network
remote closed loop test
url https://www.e3s-conferences.org/articles/e3sconf/pdf/2021/36/e3sconf_aepee2021_02006.pdf
work_keys_str_mv AT guoqi aremotetestmethodforpowergridsecurityandstabilitycontrolsystemanditsengineeringapplication
AT zhuyihua aremotetestmethodforpowergridsecurityandstabilitycontrolsystemanditsengineeringapplication
AT changdongxu aremotetestmethodforpowergridsecurityandstabilitycontrolsystemanditsengineeringapplication
AT lishengnan aremotetestmethodforpowergridsecurityandstabilitycontrolsystemanditsengineeringapplication
AT chenyong aremotetestmethodforpowergridsecurityandstabilitycontrolsystemanditsengineeringapplication
AT wumingkang aremotetestmethodforpowergridsecurityandstabilitycontrolsystemanditsengineeringapplication
AT guoqi remotetestmethodforpowergridsecurityandstabilitycontrolsystemanditsengineeringapplication
AT zhuyihua remotetestmethodforpowergridsecurityandstabilitycontrolsystemanditsengineeringapplication
AT changdongxu remotetestmethodforpowergridsecurityandstabilitycontrolsystemanditsengineeringapplication
AT lishengnan remotetestmethodforpowergridsecurityandstabilitycontrolsystemanditsengineeringapplication
AT chenyong remotetestmethodforpowergridsecurityandstabilitycontrolsystemanditsengineeringapplication
AT wumingkang remotetestmethodforpowergridsecurityandstabilitycontrolsystemanditsengineeringapplication
_version_ 1721423473612423168