Calculation of compensating susceptance for a three-wire net

A problem of inactive power compensation in a three-wire three-phase network under asymmetrical sinusoidal voltage is considered. An algorithm for calculating susceptance of a Δ-compensator for the total current component active power of which equals zero is introduced. Examples of calculation are g...

Full description

Bibliographic Details
Main Author: Yu.А. Sirotin
Format: Article
Language:English
Published: National Technical University "Kharkiv Polytechnic Institute" 2014-03-01
Series:Електротехніка і електромеханіка
Subjects:
Online Access:http://eie.khpi.edu.ua/article/view/22462/20079
id doaj-8aebb76f85b749a393170633ff5efcf2
record_format Article
spelling doaj-8aebb76f85b749a393170633ff5efcf22021-07-02T08:32:55ZengNational Technical University "Kharkiv Polytechnic Institute"Електротехніка і електромеханіка2074-272X2014-03-0117174Calculation of compensating susceptance for a three-wire netYu.А. Sirotin0National Technical University "Kharkiv Polytechnic Institute"A problem of inactive power compensation in a three-wire three-phase network under asymmetrical sinusoidal voltage is considered. An algorithm for calculating susceptance of a Δ-compensator for the total current component active power of which equals zero is introduced. Examples of calculation are given.http://eie.khpi.edu.ua/article/view/22462/20079three-phase networkcompensationasymmetrical voltagereactive power
collection DOAJ
language English
format Article
sources DOAJ
author Yu.А. Sirotin
spellingShingle Yu.А. Sirotin
Calculation of compensating susceptance for a three-wire net
Електротехніка і електромеханіка
three-phase network
compensation
asymmetrical voltage
reactive power
author_facet Yu.А. Sirotin
author_sort Yu.А. Sirotin
title Calculation of compensating susceptance for a three-wire net
title_short Calculation of compensating susceptance for a three-wire net
title_full Calculation of compensating susceptance for a three-wire net
title_fullStr Calculation of compensating susceptance for a three-wire net
title_full_unstemmed Calculation of compensating susceptance for a three-wire net
title_sort calculation of compensating susceptance for a three-wire net
publisher National Technical University "Kharkiv Polytechnic Institute"
series Електротехніка і електромеханіка
issn 2074-272X
publishDate 2014-03-01
description A problem of inactive power compensation in a three-wire three-phase network under asymmetrical sinusoidal voltage is considered. An algorithm for calculating susceptance of a Δ-compensator for the total current component active power of which equals zero is introduced. Examples of calculation are given.
topic three-phase network
compensation
asymmetrical voltage
reactive power
url http://eie.khpi.edu.ua/article/view/22462/20079
work_keys_str_mv AT yuasirotin calculationofcompensatingsusceptanceforathreewirenet
_version_ 1721334643348733952