Resonances detected on a historical tower under bells’ forced vibrations
The aim of the paper is to perform a preliminary assessment of the dynamic behavior of the bell tower of Basilica Church “S.S. Medici”, one of the most important church in the town of Bitonto, Bari, Italy. The tower is 55 m tall and it is made in reinforced concrete. It is totally disconnected from...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Gruppo Italiano Frattura
2018-09-01
|
Series: | Frattura ed Integrità Strutturale |
Subjects: | |
Online Access: | https://www.fracturae.com/index.php/fis/article/view/2138 |
id |
doaj-8ab10b20bbb241b8959aa101faf7852e |
---|---|
record_format |
Article |
spelling |
doaj-8ab10b20bbb241b8959aa101faf7852e2021-01-27T17:14:34ZengGruppo Italiano FratturaFrattura ed Integrità Strutturale1971-89932018-09-011246Resonances detected on a historical tower under bells’ forced vibrationsDora Foti0Salvador Ivorra1Mariella Diaferio2David Bru3Vitantonio Vacca4Polytechnic University of BariUniversity of AlicantePolytechnic University of BariUniversity of AlicantePolytechnic University of Bari The aim of the paper is to perform a preliminary assessment of the dynamic behavior of the bell tower of Basilica Church “S.S. Medici”, one of the most important church in the town of Bitonto, Bari, Italy. The tower is 55 m tall and it is made in reinforced concrete. It is totally disconnected from the main structure of the Church. The structural behavior of the tower has been investigated by performing dynamic experimental tests, which have been executed in two different forcing conditions: recording the vibrations induced only by ambient loads, and, then the ones due to ambient loads and to the excitation produced by the bells. Four bells are housed in the lower bell chamber on a concrete bell frame, four more bells are housed at a higher level bell frame. All the bells are directly connected to the tower and swing in the same direction, so that their movement introduces a dynamic excitation on the tower. The experimental records have detected excessive movements on the tower when bells swing. https://www.fracturae.com/index.php/fis/article/view/2138Dynamic tesConcreteBell towerBell swinging |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Dora Foti Salvador Ivorra Mariella Diaferio David Bru Vitantonio Vacca |
spellingShingle |
Dora Foti Salvador Ivorra Mariella Diaferio David Bru Vitantonio Vacca Resonances detected on a historical tower under bells’ forced vibrations Frattura ed Integrità Strutturale Dynamic tes Concrete Bell tower Bell swinging |
author_facet |
Dora Foti Salvador Ivorra Mariella Diaferio David Bru Vitantonio Vacca |
author_sort |
Dora Foti |
title |
Resonances detected on a historical tower under bells’ forced vibrations |
title_short |
Resonances detected on a historical tower under bells’ forced vibrations |
title_full |
Resonances detected on a historical tower under bells’ forced vibrations |
title_fullStr |
Resonances detected on a historical tower under bells’ forced vibrations |
title_full_unstemmed |
Resonances detected on a historical tower under bells’ forced vibrations |
title_sort |
resonances detected on a historical tower under bells’ forced vibrations |
publisher |
Gruppo Italiano Frattura |
series |
Frattura ed Integrità Strutturale |
issn |
1971-8993 |
publishDate |
2018-09-01 |
description |
The aim of the paper is to perform a preliminary assessment of the dynamic behavior of the bell tower of Basilica Church “S.S. Medici”, one of the most important church in the town of Bitonto, Bari, Italy. The tower is 55 m tall and it is made in reinforced concrete. It is totally disconnected from the main structure of the Church. The structural behavior of the tower has been investigated by performing dynamic experimental tests, which have been executed in two different forcing conditions: recording the vibrations induced only by ambient loads, and, then the ones due to ambient loads and to the excitation produced by the bells. Four bells are housed in the lower bell chamber on a concrete bell frame, four more bells are housed at a higher level bell frame. All the bells are directly connected to the tower and swing in the same direction, so that their movement introduces a dynamic excitation on the tower. The experimental records have detected excessive movements on the tower when bells swing.
|
topic |
Dynamic tes Concrete Bell tower Bell swinging |
url |
https://www.fracturae.com/index.php/fis/article/view/2138 |
work_keys_str_mv |
AT dorafoti resonancesdetectedonahistoricaltowerunderbellsforcedvibrations AT salvadorivorra resonancesdetectedonahistoricaltowerunderbellsforcedvibrations AT marielladiaferio resonancesdetectedonahistoricaltowerunderbellsforcedvibrations AT davidbru resonancesdetectedonahistoricaltowerunderbellsforcedvibrations AT vitantoniovacca resonancesdetectedonahistoricaltowerunderbellsforcedvibrations |
_version_ |
1724320824578539520 |