Usefulness of Surgical Media Center as a Cataract Surgery Educational Tool
Purpose. This study retrospectively analyzed cataract surgeries to examine the usefulness of Surgical Media Center (SMC) (Abbott Medical Optics Inc.), a new cataract surgery recording device, for training of cataract surgery. Methods. We studied five hundred cataract surgeries conducted with a phaco...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Hindawi Limited
2016-01-01
|
Series: | Journal of Ophthalmology |
Online Access: | http://dx.doi.org/10.1155/2016/8435086 |
id |
doaj-8a5ef6157e724d1d885b3c38cbd51e36 |
---|---|
record_format |
Article |
spelling |
doaj-8a5ef6157e724d1d885b3c38cbd51e362020-11-24T23:02:08ZengHindawi LimitedJournal of Ophthalmology2090-004X2090-00582016-01-01201610.1155/2016/84350868435086Usefulness of Surgical Media Center as a Cataract Surgery Educational ToolTomoichiro Ogawa0Takuya Shiba1Hiroshi Tsuneoka2Department of Ophthalmology, The Jikei University School of Medicine, 3-25-8 Nishishinbashi, Minato-ku, Tokyo 105-0003, JapanDepartment of Ophthalmology, The Jikei University School of Medicine, 3-25-8 Nishishinbashi, Minato-ku, Tokyo 105-0003, JapanDepartment of Ophthalmology, The Jikei University School of Medicine, 3-25-8 Nishishinbashi, Minato-ku, Tokyo 105-0003, JapanPurpose. This study retrospectively analyzed cataract surgeries to examine the usefulness of Surgical Media Center (SMC) (Abbott Medical Optics Inc.), a new cataract surgery recording device, for training of cataract surgery. Methods. We studied five hundred cataract surgeries conducted with a phacoemulsification system connected to the SMC. After surgery, the surgical procedures were reviewed, with changes in aspiration rate, vacuum level, and phaco power displayed as graphs superimposed on the surgical video. We examined whether use of SMC is able to demonstrate the differences in technique between experienced and trainee operators, to identify inappropriate phacoemulsification techniques from analyzing the graphs, and to elucidate the cause of intraoperative complications. Results. Significant differences in the time taken to reach maximum vacuum and the speed of increase in vacuum during irrigation and aspiration were observed between experienced and trainee operators. Analysis of the graphs displayed by SMC detected inappropriate phacoemulsification techniques mostly in cases operated by trainee operators. Conclusions. Using SMC, it was possible to capture details of cataract surgery objectively. This recording device allows surgeons to review cataract surgery techniques and identify the cause of intraoperative complication and is a useful education tool for cataract surgery.http://dx.doi.org/10.1155/2016/8435086 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Tomoichiro Ogawa Takuya Shiba Hiroshi Tsuneoka |
spellingShingle |
Tomoichiro Ogawa Takuya Shiba Hiroshi Tsuneoka Usefulness of Surgical Media Center as a Cataract Surgery Educational Tool Journal of Ophthalmology |
author_facet |
Tomoichiro Ogawa Takuya Shiba Hiroshi Tsuneoka |
author_sort |
Tomoichiro Ogawa |
title |
Usefulness of Surgical Media Center as a Cataract Surgery Educational Tool |
title_short |
Usefulness of Surgical Media Center as a Cataract Surgery Educational Tool |
title_full |
Usefulness of Surgical Media Center as a Cataract Surgery Educational Tool |
title_fullStr |
Usefulness of Surgical Media Center as a Cataract Surgery Educational Tool |
title_full_unstemmed |
Usefulness of Surgical Media Center as a Cataract Surgery Educational Tool |
title_sort |
usefulness of surgical media center as a cataract surgery educational tool |
publisher |
Hindawi Limited |
series |
Journal of Ophthalmology |
issn |
2090-004X 2090-0058 |
publishDate |
2016-01-01 |
description |
Purpose. This study retrospectively analyzed cataract surgeries to examine the usefulness of Surgical Media Center (SMC) (Abbott Medical Optics Inc.), a new cataract surgery recording device, for training of cataract surgery. Methods. We studied five hundred cataract surgeries conducted with a phacoemulsification system connected to the SMC. After surgery, the surgical procedures were reviewed, with changes in aspiration rate, vacuum level, and phaco power displayed as graphs superimposed on the surgical video. We examined whether use of SMC is able to demonstrate the differences in technique between experienced and trainee operators, to identify inappropriate phacoemulsification techniques from analyzing the graphs, and to elucidate the cause of intraoperative complications. Results. Significant differences in the time taken to reach maximum vacuum and the speed of increase in vacuum during irrigation and aspiration were observed between experienced and trainee operators. Analysis of the graphs displayed by SMC detected inappropriate phacoemulsification techniques mostly in cases operated by trainee operators. Conclusions. Using SMC, it was possible to capture details of cataract surgery objectively. This recording device allows surgeons to review cataract surgery techniques and identify the cause of intraoperative complication and is a useful education tool for cataract surgery. |
url |
http://dx.doi.org/10.1155/2016/8435086 |
work_keys_str_mv |
AT tomoichiroogawa usefulnessofsurgicalmediacenterasacataractsurgeryeducationaltool AT takuyashiba usefulnessofsurgicalmediacenterasacataractsurgeryeducationaltool AT hiroshitsuneoka usefulnessofsurgicalmediacenterasacataractsurgeryeducationaltool |
_version_ |