Laser Welding on Cerclage Wire Joining in Femur Surgery
Stainless steel wires with fiber-laser welding on lap joints are first proposed in this study to be used as cerclage wire joints for modern femur surgery, because of their potentially larger joint strength and less loosening failure than traditional joint devices. In this feasibility study, an exper...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2020-04-01
|
Series: | Applied Sciences |
Subjects: | |
Online Access: | https://www.mdpi.com/2076-3417/10/7/2407 |
id |
doaj-8a4e58f0327243928f460104ef70ba52 |
---|---|
record_format |
Article |
spelling |
doaj-8a4e58f0327243928f460104ef70ba522020-11-25T02:11:26ZengMDPI AGApplied Sciences2076-34172020-04-01102407240710.3390/app10072407Laser Welding on Cerclage Wire Joining in Femur SurgeryNutchanat Thongchuea0Eakkachai Warinsiriruk1Yin-Tien Wang2Department of Industrial Engineering, Mahidol University, Nakhon Pathom 73170, Bangkok, ThailandDepartment of Industrial Engineering, Mahidol University, Nakhon Pathom 73170, Bangkok, ThailandDepartment of Mechanical and Electro-Mechanical Engineering, Tamkang University, New Taipei City 25137, TaiwanStainless steel wires with fiber-laser welding on lap joints are first proposed in this study to be used as cerclage wire joints for modern femur surgery, because of their potentially larger joint strength and less loosening failure than traditional joint devices. In this feasibility study, an experiment was set up to determine adequate parameters for the laser welding process in order to ensure that the wire joint of cerclage has good weld appearance, free oxidation, and suitable joint strength. A stainless steel wire 316L with a diameter of 1.6 mm, flare-welded on lap joint was used in the experiment as a specimen cerclage wire joint. Two major effective parameters were chosen for controlling a suitable fusion weld, including charge voltage and multiple frequencies of the laser irradiation. The adequate area of the laser parameters was determined from the experiment, including the ranges of charge voltage, multiple frequencies, and pulse width. The suitable welded lengths of specimens were also studied in the mechanical test to validate the joint strength. Suggested welded length has a better tensile strength than traditional cerclage joints. The paper concludes that the stainless wire joints with a fiber laser weld represents a promising alternative to traditional cerclage joint devices for modern femur surgery.https://www.mdpi.com/2076-3417/10/7/2407cerclage wirerobot-assisted laser weldinglaser welding parameterswire joint tensile strength |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Nutchanat Thongchuea Eakkachai Warinsiriruk Yin-Tien Wang |
spellingShingle |
Nutchanat Thongchuea Eakkachai Warinsiriruk Yin-Tien Wang Laser Welding on Cerclage Wire Joining in Femur Surgery Applied Sciences cerclage wire robot-assisted laser welding laser welding parameters wire joint tensile strength |
author_facet |
Nutchanat Thongchuea Eakkachai Warinsiriruk Yin-Tien Wang |
author_sort |
Nutchanat Thongchuea |
title |
Laser Welding on Cerclage Wire Joining in Femur Surgery |
title_short |
Laser Welding on Cerclage Wire Joining in Femur Surgery |
title_full |
Laser Welding on Cerclage Wire Joining in Femur Surgery |
title_fullStr |
Laser Welding on Cerclage Wire Joining in Femur Surgery |
title_full_unstemmed |
Laser Welding on Cerclage Wire Joining in Femur Surgery |
title_sort |
laser welding on cerclage wire joining in femur surgery |
publisher |
MDPI AG |
series |
Applied Sciences |
issn |
2076-3417 |
publishDate |
2020-04-01 |
description |
Stainless steel wires with fiber-laser welding on lap joints are first proposed in this study to be used as cerclage wire joints for modern femur surgery, because of their potentially larger joint strength and less loosening failure than traditional joint devices. In this feasibility study, an experiment was set up to determine adequate parameters for the laser welding process in order to ensure that the wire joint of cerclage has good weld appearance, free oxidation, and suitable joint strength. A stainless steel wire 316L with a diameter of 1.6 mm, flare-welded on lap joint was used in the experiment as a specimen cerclage wire joint. Two major effective parameters were chosen for controlling a suitable fusion weld, including charge voltage and multiple frequencies of the laser irradiation. The adequate area of the laser parameters was determined from the experiment, including the ranges of charge voltage, multiple frequencies, and pulse width. The suitable welded lengths of specimens were also studied in the mechanical test to validate the joint strength. Suggested welded length has a better tensile strength than traditional cerclage joints. The paper concludes that the stainless wire joints with a fiber laser weld represents a promising alternative to traditional cerclage joint devices for modern femur surgery. |
topic |
cerclage wire robot-assisted laser welding laser welding parameters wire joint tensile strength |
url |
https://www.mdpi.com/2076-3417/10/7/2407 |
work_keys_str_mv |
AT nutchanatthongchuea laserweldingoncerclagewirejoininginfemursurgery AT eakkachaiwarinsiriruk laserweldingoncerclagewirejoininginfemursurgery AT yintienwang laserweldingoncerclagewirejoininginfemursurgery |
_version_ |
1724914179967549440 |