Comparison of real-time water proton spectroscopy and echo-planar imaging sensitivity to the BOLD effect at 3 T and at 7 T.
Gradient-echo echo-planar imaging (GE EPI) is the most commonly used approach to assess localized blood oxygen level dependent (BOLD) signal changes in real-time. Alternatively, real-time spin-echo single-voxel spectroscopy (SE SVS) has recently been introduced for spatially specific BOLD neurofeedb...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Public Library of Science (PLoS)
2014-01-01
|
Series: | PLoS ONE |
Online Access: | https://www.ncbi.nlm.nih.gov/pmc/articles/pmid/24614912/pdf/?tool=EBI |
id |
doaj-8a28c4fe51c041f78d16c104205b69f9 |
---|---|
record_format |
Article |
spelling |
doaj-8a28c4fe51c041f78d16c104205b69f92021-03-04T11:56:52ZengPublic Library of Science (PLoS)PLoS ONE1932-62032014-01-0193e9162010.1371/journal.pone.0091620Comparison of real-time water proton spectroscopy and echo-planar imaging sensitivity to the BOLD effect at 3 T and at 7 T.Yury KoushMark A ElliottFrank ScharnowskiKlaus MathiakGradient-echo echo-planar imaging (GE EPI) is the most commonly used approach to assess localized blood oxygen level dependent (BOLD) signal changes in real-time. Alternatively, real-time spin-echo single-voxel spectroscopy (SE SVS) has recently been introduced for spatially specific BOLD neurofeedback at 3 T and at 7 T. However, currently it is not known how neurofeedback based on real-time SE SVS compares to real-time GE EPI-based. We therefore compared both methods at high (3 T) and at ultra-high (7 T) magnetic field strengths. We evaluated standard quality measures of both methods for signals originating from the motor cortex, the visual cortex, and for a neurofeedback condition. At 3 T, the data quality of the real-time SE SVS and GE EPI R2* estimates were comparable. At 7 T, the data quality of the real-time GE EPI acquisitions was superior compared to those of the real-time SE SVS. Despite the somehow lower data quality of real-time SE SVS compared to GE EPI at 7 T, SE SVS acquisitions might still be an interesting alternative. Real-time SE SVS allows for a direct and subject-specific T2* estimation and thus for a physiologically more plausible neurofeedback signal.https://www.ncbi.nlm.nih.gov/pmc/articles/pmid/24614912/pdf/?tool=EBI |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Yury Koush Mark A Elliott Frank Scharnowski Klaus Mathiak |
spellingShingle |
Yury Koush Mark A Elliott Frank Scharnowski Klaus Mathiak Comparison of real-time water proton spectroscopy and echo-planar imaging sensitivity to the BOLD effect at 3 T and at 7 T. PLoS ONE |
author_facet |
Yury Koush Mark A Elliott Frank Scharnowski Klaus Mathiak |
author_sort |
Yury Koush |
title |
Comparison of real-time water proton spectroscopy and echo-planar imaging sensitivity to the BOLD effect at 3 T and at 7 T. |
title_short |
Comparison of real-time water proton spectroscopy and echo-planar imaging sensitivity to the BOLD effect at 3 T and at 7 T. |
title_full |
Comparison of real-time water proton spectroscopy and echo-planar imaging sensitivity to the BOLD effect at 3 T and at 7 T. |
title_fullStr |
Comparison of real-time water proton spectroscopy and echo-planar imaging sensitivity to the BOLD effect at 3 T and at 7 T. |
title_full_unstemmed |
Comparison of real-time water proton spectroscopy and echo-planar imaging sensitivity to the BOLD effect at 3 T and at 7 T. |
title_sort |
comparison of real-time water proton spectroscopy and echo-planar imaging sensitivity to the bold effect at 3 t and at 7 t. |
publisher |
Public Library of Science (PLoS) |
series |
PLoS ONE |
issn |
1932-6203 |
publishDate |
2014-01-01 |
description |
Gradient-echo echo-planar imaging (GE EPI) is the most commonly used approach to assess localized blood oxygen level dependent (BOLD) signal changes in real-time. Alternatively, real-time spin-echo single-voxel spectroscopy (SE SVS) has recently been introduced for spatially specific BOLD neurofeedback at 3 T and at 7 T. However, currently it is not known how neurofeedback based on real-time SE SVS compares to real-time GE EPI-based. We therefore compared both methods at high (3 T) and at ultra-high (7 T) magnetic field strengths. We evaluated standard quality measures of both methods for signals originating from the motor cortex, the visual cortex, and for a neurofeedback condition. At 3 T, the data quality of the real-time SE SVS and GE EPI R2* estimates were comparable. At 7 T, the data quality of the real-time GE EPI acquisitions was superior compared to those of the real-time SE SVS. Despite the somehow lower data quality of real-time SE SVS compared to GE EPI at 7 T, SE SVS acquisitions might still be an interesting alternative. Real-time SE SVS allows for a direct and subject-specific T2* estimation and thus for a physiologically more plausible neurofeedback signal. |
url |
https://www.ncbi.nlm.nih.gov/pmc/articles/pmid/24614912/pdf/?tool=EBI |
work_keys_str_mv |
AT yurykoush comparisonofrealtimewaterprotonspectroscopyandechoplanarimagingsensitivitytotheboldeffectat3tandat7t AT markaelliott comparisonofrealtimewaterprotonspectroscopyandechoplanarimagingsensitivitytotheboldeffectat3tandat7t AT frankscharnowski comparisonofrealtimewaterprotonspectroscopyandechoplanarimagingsensitivitytotheboldeffectat3tandat7t AT klausmathiak comparisonofrealtimewaterprotonspectroscopyandechoplanarimagingsensitivitytotheboldeffectat3tandat7t |
_version_ |
1714803231191728128 |