Effect of location and dimensions of welded cover plate on stress intensity factors of cracked plates
Three dimensional finite element model was utilized to determine mode I stress intensity factor through the front of a single edge crack in main plate with welded cover plate. The numerical results showed that the ratio of the crack length to the position of the welded cover plate end is a crucial p...
Main Author: | Amr A. Abd-Elhady |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2013-12-01
|
Series: | Ain Shams Engineering Journal |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S2090447913000373 |
Similar Items
-
Stress intensity factor for small embedded cracks in weldments
by: Paolo Livieri, et al.
Published: (2019-09-01) -
Stress intensity factor for small embedded cracks in weldments
by: Paolo Livieri, et al.
Published: (2019-10-01) -
Welding process of blocking plate in large power station
by: RONG Yi, et al.
Published: (2019-10-01) -
A plan of welding the 65 kW plate heat exchanger
by: Jacek Słania, et al.
Published: (2017-02-01) -
Are three-dimensional plates as effective as superior border plating in mandibular angle fractures? A comparative evaluation of effectiveness
by: E Santhosh Kumar, et al.
Published: (2018-01-01)