A Reliable Flow-Based Method for the Accurate Measure of Mass Density, Size and Weight of Live 3D Tumor Spheroids
Gathering precise information on mass density, size and weight of cells or cell aggregates, is crucial for applications in many biomedical fields with a specific focus on cancer research. Although few technical solutions have been presented for single-cell analysis, literature does not cover this as...
Main Authors: | Domenico Andrea Cristaldi, Azzurra Sargenti, Simone Bonetti, Francesco Musmeci, Cecilia Delprete, Francesco Bacchi, Simone Pasqua, Carola Cavallo, Laura Bonsi, Francesco Alviano, Daniele Gazzola, Spartaco Santi |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2020-04-01
|
Series: | Micromachines |
Subjects: | |
Online Access: | https://www.mdpi.com/2072-666X/11/5/465 |
Similar Items
-
Physical Characterization of Colorectal Cancer Spheroids and Evaluation of NK Cell Infiltration Through a Flow-Based Analysis
by: Azzurra Sargenti, et al.
Published: (2020-12-01) -
A new method for the study of biophysical and morphological parameters in 3D cell cultures: Evaluation in LoVo spheroids treated with crizotinib.
by: Azzurra Sargenti, et al.
Published: (2021-01-01) -
Spheroidal Degeneration of the Cornea
by: Erdem Dinç, et al.
Published: (2011-08-01) -
The interaction energy of two uniformly charged spheroids. Example of deformed nuclei
by: S. Ya. Goroshchenko, et al.
Published: (2020-03-01) -
SIZE AND SHAPE FACTOR EXTREMES OF SPHEROIDS
by: Daniel Hlubinka
Published: (2011-05-01)