Examination of Multivalent Diagnoses Developed by a Diagnostic Program with an Artificial Neural Network for Devices in the Electric Hybrid Power Supply System “House on Water”
<b>: </b>This article presents the problem of diagnostic examination by the (DIAG) diagnostic system of devices of the House on Water (HoW) hybrid electric power system in the multi-valued (2, 3, and 4) state assessment. Forming the basis for the functioning of the (DIAG) diagnostic syst...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2021-04-01
|
Series: | Energies |
Subjects: | |
Online Access: | https://www.mdpi.com/1996-1073/14/8/2153 |
id |
doaj-89490d8d733641faa5ad9ca694dd044f |
---|---|
record_format |
Article |
spelling |
doaj-89490d8d733641faa5ad9ca694dd044f2021-04-12T23:05:28ZengMDPI AGEnergies1996-10732021-04-01142153215310.3390/en14082153Examination of Multivalent Diagnoses Developed by a Diagnostic Program with an Artificial Neural Network for Devices in the Electric Hybrid Power Supply System “House on Water”Stanisław Duer0Konrad Zajkowski1Marta Harničárová2Henryk Charun3Dariusz Bernatowicz4Department of Energy, Faculty of Mechanical Engineering, Technical University of Koszalin, 15-17 Raclawicka St., 75-620 Koszalin, PolandDepartment of Energy, Faculty of Mechanical Engineering, Technical University of Koszalin, 15-17 Raclawicka St., 75-620 Koszalin, PolandDepartment of Mechanical Engineering, Faculty of Technology, Institute of Technology and Business in České Budějovice, Okružní 10, 370 01 České Budějovice, Czech RepublicDepartment of Energy, Faculty of Mechanical Engineering, Technical University of Koszalin, 15-17 Raclawicka St., 75-620 Koszalin, PolandFaculty of Electronic and Informatic, Technical University of Koszalin, 2 Sniadeckich St., 75-620 Koszalin, Poland<b>: </b>This article presents the problem of diagnostic examination by the (DIAG) diagnostic system of devices of the House on Water (HoW) hybrid electric power system in the multi-valued (2, 3, and 4) state assessment. Forming the basis for the functioning of the (DIAG) diagnostic system is the measurement knowledge base of the object tested. For this purpose, the issues of building a diagnostic knowledge base for a hybrid power system for HoW are presented. The basis for obtaining diagnostic information for the measurement knowledge base is a functional and diagnostic analysis of the hybrid power system tested. The result of this analysis is a functional and diagnostic model of the research object. At the next stage of the work, on the basis of the model created, the sets of basic elements and the sets of measurement signals were determined together with the reference signals assigned. State classification in the (DIAG) system is based on an analysis of the value of the divergence metrics of the signal vectors tested. The purpose of the HoW diagnostic test is to assess an increase in the diagnoses developed by the intelligent diagnostic system (DIAG 2) in 4-valued logic in relation to the assessments in 3- and 2-valued logic.https://www.mdpi.com/1996-1073/14/8/2153technical diagnosticsdiagnostic reasoningmultivalent logicartificial intelligencehybrid power system |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Stanisław Duer Konrad Zajkowski Marta Harničárová Henryk Charun Dariusz Bernatowicz |
spellingShingle |
Stanisław Duer Konrad Zajkowski Marta Harničárová Henryk Charun Dariusz Bernatowicz Examination of Multivalent Diagnoses Developed by a Diagnostic Program with an Artificial Neural Network for Devices in the Electric Hybrid Power Supply System “House on Water” Energies technical diagnostics diagnostic reasoning multivalent logic artificial intelligence hybrid power system |
author_facet |
Stanisław Duer Konrad Zajkowski Marta Harničárová Henryk Charun Dariusz Bernatowicz |
author_sort |
Stanisław Duer |
title |
Examination of Multivalent Diagnoses Developed by a Diagnostic Program with an Artificial Neural Network for Devices in the Electric Hybrid Power Supply System “House on Water” |
title_short |
Examination of Multivalent Diagnoses Developed by a Diagnostic Program with an Artificial Neural Network for Devices in the Electric Hybrid Power Supply System “House on Water” |
title_full |
Examination of Multivalent Diagnoses Developed by a Diagnostic Program with an Artificial Neural Network for Devices in the Electric Hybrid Power Supply System “House on Water” |
title_fullStr |
Examination of Multivalent Diagnoses Developed by a Diagnostic Program with an Artificial Neural Network for Devices in the Electric Hybrid Power Supply System “House on Water” |
title_full_unstemmed |
Examination of Multivalent Diagnoses Developed by a Diagnostic Program with an Artificial Neural Network for Devices in the Electric Hybrid Power Supply System “House on Water” |
title_sort |
examination of multivalent diagnoses developed by a diagnostic program with an artificial neural network for devices in the electric hybrid power supply system “house on water” |
publisher |
MDPI AG |
series |
Energies |
issn |
1996-1073 |
publishDate |
2021-04-01 |
description |
<b>: </b>This article presents the problem of diagnostic examination by the (DIAG) diagnostic system of devices of the House on Water (HoW) hybrid electric power system in the multi-valued (2, 3, and 4) state assessment. Forming the basis for the functioning of the (DIAG) diagnostic system is the measurement knowledge base of the object tested. For this purpose, the issues of building a diagnostic knowledge base for a hybrid power system for HoW are presented. The basis for obtaining diagnostic information for the measurement knowledge base is a functional and diagnostic analysis of the hybrid power system tested. The result of this analysis is a functional and diagnostic model of the research object. At the next stage of the work, on the basis of the model created, the sets of basic elements and the sets of measurement signals were determined together with the reference signals assigned. State classification in the (DIAG) system is based on an analysis of the value of the divergence metrics of the signal vectors tested. The purpose of the HoW diagnostic test is to assess an increase in the diagnoses developed by the intelligent diagnostic system (DIAG 2) in 4-valued logic in relation to the assessments in 3- and 2-valued logic. |
topic |
technical diagnostics diagnostic reasoning multivalent logic artificial intelligence hybrid power system |
url |
https://www.mdpi.com/1996-1073/14/8/2153 |
work_keys_str_mv |
AT stanisławduer examinationofmultivalentdiagnosesdevelopedbyadiagnosticprogramwithanartificialneuralnetworkfordevicesintheelectrichybridpowersupplysystemhouseonwater AT konradzajkowski examinationofmultivalentdiagnosesdevelopedbyadiagnosticprogramwithanartificialneuralnetworkfordevicesintheelectrichybridpowersupplysystemhouseonwater AT martaharnicarova examinationofmultivalentdiagnosesdevelopedbyadiagnosticprogramwithanartificialneuralnetworkfordevicesintheelectrichybridpowersupplysystemhouseonwater AT henrykcharun examinationofmultivalentdiagnosesdevelopedbyadiagnosticprogramwithanartificialneuralnetworkfordevicesintheelectrichybridpowersupplysystemhouseonwater AT dariuszbernatowicz examinationofmultivalentdiagnosesdevelopedbyadiagnosticprogramwithanartificialneuralnetworkfordevicesintheelectrichybridpowersupplysystemhouseonwater |
_version_ |
1721529387293081600 |