Evaluation of a new arterial pressure-based cardiac output device requiring no external calibration

<p>Abstract</p> <p>Background</p> <p>Several techniques have been discussed as alternatives to the intermittent bolus thermodilution cardiac output (CO<sub>PAC</sub>) measurement by the pulmonary artery catheter (PAC). However, these techniques usually requi...

Full description

Bibliographic Details
Main Authors: Amann Matthias, Trabold Benedikt, Schweiger Stefan, Keyl Cornelius, Bele Sylvia, Prasser Christopher, Welnhofer Julia, Wiesenack Christoph
Format: Article
Language:English
Published: BMC 2007-11-01
Series:BMC Anesthesiology
Online Access:http://www.biomedcentral.com/1471-2253/7/9
id doaj-892db8401dcd45f9addc2f00b128562e
record_format Article
spelling doaj-892db8401dcd45f9addc2f00b128562e2020-11-25T03:42:49ZengBMCBMC Anesthesiology1471-22532007-11-0171910.1186/1471-2253-7-9Evaluation of a new arterial pressure-based cardiac output device requiring no external calibrationAmann MatthiasTrabold BenediktSchweiger StefanKeyl CorneliusBele SylviaPrasser ChristopherWelnhofer JuliaWiesenack Christoph<p>Abstract</p> <p>Background</p> <p>Several techniques have been discussed as alternatives to the intermittent bolus thermodilution cardiac output (CO<sub>PAC</sub>) measurement by the pulmonary artery catheter (PAC). However, these techniques usually require a central venous line, an additional catheter, or a special calibration procedure. A new arterial pressure-based cardiac output (CO<sub>AP</sub>) device (FloTrac™, Vigileo™; Edwards Lifesciences, Irvine, CA, USA) only requires access to the radial or femoral artery using a standard arterial catheter and does not need an external calibration. We validated this technique in critically ill patients in the intensive care unit (ICU) using CO<sub>PAC </sub>as the method of reference.</p> <p>Methods</p> <p>We studied 20 critically ill patients, aged 16 to 74 years (mean, 55.5 ± 18.8 years), who required both arterial and pulmonary artery pressure monitoring. CO<sub>PAC </sub>measurements were performed at least every 4 hours and calculated as the average of 3 measurements, while CO<sub>AP </sub>values were taken immediately at the end of bolus determinations. Accuracy of measurements was assessed by calculating the bias and limits of agreement using the method described by Bland and Altman.</p> <p>Results</p> <p>A total of 164 coupled measurements were obtained. Absolute values of CO<sub>PAC </sub>ranged from 2.80 to 10.80 l/min (mean 5.93 ± 1.55 l/min). The bias and limits of agreement between CO<sub>PAC </sub>and CO<sub>AP </sub>for unequal numbers of replicates was 0.02 ± 2.92 l/min. The percentage error between CO<sub>PAC </sub>and CO<sub>AP </sub>was 49.3%. The bias between percentage changes in CO<sub>PAC </sub>(ΔCO<sub>PAC</sub>) and percentage changes in CO<sub>AP </sub>(ΔCO<sub>AP</sub>) for consecutive measurements was -0.70% ± 32.28%. CO<sub>PAC </sub>and CO<sub>AP </sub>showed a Pearson correlation coefficient of 0.58 (<it>p </it>< 0.01), while the correlation coefficient between ΔCO<sub>PAC </sub>and ΔCO<sub>AP </sub>was 0.46 (<it>p </it>< 0.01).</p> <p>Conclusion</p> <p>Although the CO<sub>AP </sub>algorithm shows a minimal bias with CO<sub>PAC </sub>over a wide range of values in an inhomogeneous group of critically ill patients, the scattering of the data remains relative wide. Therefore, the used algorithm (V 1.03) failed to demonstrate an acceptable accuracy in comparison to the clinical standard of cardiac output determination.</p> http://www.biomedcentral.com/1471-2253/7/9
collection DOAJ
language English
format Article
sources DOAJ
author Amann Matthias
Trabold Benedikt
Schweiger Stefan
Keyl Cornelius
Bele Sylvia
Prasser Christopher
Welnhofer Julia
Wiesenack Christoph
spellingShingle Amann Matthias
Trabold Benedikt
Schweiger Stefan
Keyl Cornelius
Bele Sylvia
Prasser Christopher
Welnhofer Julia
Wiesenack Christoph
Evaluation of a new arterial pressure-based cardiac output device requiring no external calibration
BMC Anesthesiology
author_facet Amann Matthias
Trabold Benedikt
Schweiger Stefan
Keyl Cornelius
Bele Sylvia
Prasser Christopher
Welnhofer Julia
Wiesenack Christoph
author_sort Amann Matthias
title Evaluation of a new arterial pressure-based cardiac output device requiring no external calibration
title_short Evaluation of a new arterial pressure-based cardiac output device requiring no external calibration
title_full Evaluation of a new arterial pressure-based cardiac output device requiring no external calibration
title_fullStr Evaluation of a new arterial pressure-based cardiac output device requiring no external calibration
title_full_unstemmed Evaluation of a new arterial pressure-based cardiac output device requiring no external calibration
title_sort evaluation of a new arterial pressure-based cardiac output device requiring no external calibration
publisher BMC
series BMC Anesthesiology
issn 1471-2253
publishDate 2007-11-01
description <p>Abstract</p> <p>Background</p> <p>Several techniques have been discussed as alternatives to the intermittent bolus thermodilution cardiac output (CO<sub>PAC</sub>) measurement by the pulmonary artery catheter (PAC). However, these techniques usually require a central venous line, an additional catheter, or a special calibration procedure. A new arterial pressure-based cardiac output (CO<sub>AP</sub>) device (FloTrac™, Vigileo™; Edwards Lifesciences, Irvine, CA, USA) only requires access to the radial or femoral artery using a standard arterial catheter and does not need an external calibration. We validated this technique in critically ill patients in the intensive care unit (ICU) using CO<sub>PAC </sub>as the method of reference.</p> <p>Methods</p> <p>We studied 20 critically ill patients, aged 16 to 74 years (mean, 55.5 ± 18.8 years), who required both arterial and pulmonary artery pressure monitoring. CO<sub>PAC </sub>measurements were performed at least every 4 hours and calculated as the average of 3 measurements, while CO<sub>AP </sub>values were taken immediately at the end of bolus determinations. Accuracy of measurements was assessed by calculating the bias and limits of agreement using the method described by Bland and Altman.</p> <p>Results</p> <p>A total of 164 coupled measurements were obtained. Absolute values of CO<sub>PAC </sub>ranged from 2.80 to 10.80 l/min (mean 5.93 ± 1.55 l/min). The bias and limits of agreement between CO<sub>PAC </sub>and CO<sub>AP </sub>for unequal numbers of replicates was 0.02 ± 2.92 l/min. The percentage error between CO<sub>PAC </sub>and CO<sub>AP </sub>was 49.3%. The bias between percentage changes in CO<sub>PAC </sub>(ΔCO<sub>PAC</sub>) and percentage changes in CO<sub>AP </sub>(ΔCO<sub>AP</sub>) for consecutive measurements was -0.70% ± 32.28%. CO<sub>PAC </sub>and CO<sub>AP </sub>showed a Pearson correlation coefficient of 0.58 (<it>p </it>< 0.01), while the correlation coefficient between ΔCO<sub>PAC </sub>and ΔCO<sub>AP </sub>was 0.46 (<it>p </it>< 0.01).</p> <p>Conclusion</p> <p>Although the CO<sub>AP </sub>algorithm shows a minimal bias with CO<sub>PAC </sub>over a wide range of values in an inhomogeneous group of critically ill patients, the scattering of the data remains relative wide. Therefore, the used algorithm (V 1.03) failed to demonstrate an acceptable accuracy in comparison to the clinical standard of cardiac output determination.</p>
url http://www.biomedcentral.com/1471-2253/7/9
work_keys_str_mv AT amannmatthias evaluationofanewarterialpressurebasedcardiacoutputdevicerequiringnoexternalcalibration
AT traboldbenedikt evaluationofanewarterialpressurebasedcardiacoutputdevicerequiringnoexternalcalibration
AT schweigerstefan evaluationofanewarterialpressurebasedcardiacoutputdevicerequiringnoexternalcalibration
AT keylcornelius evaluationofanewarterialpressurebasedcardiacoutputdevicerequiringnoexternalcalibration
AT belesylvia evaluationofanewarterialpressurebasedcardiacoutputdevicerequiringnoexternalcalibration
AT prasserchristopher evaluationofanewarterialpressurebasedcardiacoutputdevicerequiringnoexternalcalibration
AT welnhoferjulia evaluationofanewarterialpressurebasedcardiacoutputdevicerequiringnoexternalcalibration
AT wiesenackchristoph evaluationofanewarterialpressurebasedcardiacoutputdevicerequiringnoexternalcalibration
_version_ 1724523380911112192