CORRELATION: IMPEDANCE AND TOMOGRAPHY IN IMPLANTS INSERTION IN LUMBAR ARTHRODESIS

ABSTRACT Objective: To define whether the electroneurophysiological stimulation would be a safe method for reducing injuries in nerve roots during surgery of lumbar spine arthrodesis, as well as verify whether there is a direct correlation between the intraoperative impedance values and the distanc...

Full description

Bibliographic Details
Main Authors: ÉRIKO GONÇALVES FILGUEIRA, LUCIANO DE ALMEIDA FERRER, ITAMAR ALVES BARBOSA NETO, LEONARDO MORAIS PAIVA, RICARDO SUGAI, LUCIANA FEITOSA FERRER
Format: Article
Language:English
Published: Sociedade Brasileira de Coluna (SBC)
Series:Coluna/Columna
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1808-18512016000400283&lng=en&tlng=en
id doaj-891beeabbbf14003ad9f99dd50b0292e
record_format Article
spelling doaj-891beeabbbf14003ad9f99dd50b0292e2020-11-25T00:27:16ZengSociedade Brasileira de Coluna (SBC)Coluna/Columna 2177-014X15428328610.1590/s1808-185120161504162728S1808-18512016000400283CORRELATION: IMPEDANCE AND TOMOGRAPHY IN IMPLANTS INSERTION IN LUMBAR ARTHRODESISÉRIKO GONÇALVES FILGUEIRALUCIANO DE ALMEIDA FERRERITAMAR ALVES BARBOSA NETOLEONARDO MORAIS PAIVARICARDO SUGAILUCIANA FEITOSA FERRERABSTRACT Objective: To define whether the electroneurophysiological stimulation would be a safe method for reducing injuries in nerve roots during surgery of lumbar spine arthrodesis, as well as verify whether there is a direct correlation between the intraoperative impedance values and the distance from the medial cortical pedicle screw. Methods: Randomized retrospective multicenter study of 10 patients who underwent arthrodesis of lumbar spine after conservative treatment failure, with a total of 50 pedicle screws instrumented. Reliable and safe impedance values were measured in order to reduce the risk of injury to nerve roots in the perioperative period, and these values were compared with the distance between the screw and the medial cortical of the pedicle by CT scan, measured in the immediate post-operative period. Results: There is no direct correlation between the intraoperative impedance values and the distance from the screw to the medial cortical of the pedicle. Conclusion: The electroneurostimulation proved to be a reliable quantitative method to reduce the risk of injury to nerve roots during surgery of lumbar spine arthrodesis when the measured values are greater than 10mA.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1808-18512016000400283&lng=en&tlng=enArtrodeseImpedância elétricaRaízes nervosas espinhaisEstimulação elétrica.
collection DOAJ
language English
format Article
sources DOAJ
author ÉRIKO GONÇALVES FILGUEIRA
LUCIANO DE ALMEIDA FERRER
ITAMAR ALVES BARBOSA NETO
LEONARDO MORAIS PAIVA
RICARDO SUGAI
LUCIANA FEITOSA FERRER
spellingShingle ÉRIKO GONÇALVES FILGUEIRA
LUCIANO DE ALMEIDA FERRER
ITAMAR ALVES BARBOSA NETO
LEONARDO MORAIS PAIVA
RICARDO SUGAI
LUCIANA FEITOSA FERRER
CORRELATION: IMPEDANCE AND TOMOGRAPHY IN IMPLANTS INSERTION IN LUMBAR ARTHRODESIS
Coluna/Columna
Artrodese
Impedância elétrica
Raízes nervosas espinhais
Estimulação elétrica.
author_facet ÉRIKO GONÇALVES FILGUEIRA
LUCIANO DE ALMEIDA FERRER
ITAMAR ALVES BARBOSA NETO
LEONARDO MORAIS PAIVA
RICARDO SUGAI
LUCIANA FEITOSA FERRER
author_sort ÉRIKO GONÇALVES FILGUEIRA
title CORRELATION: IMPEDANCE AND TOMOGRAPHY IN IMPLANTS INSERTION IN LUMBAR ARTHRODESIS
title_short CORRELATION: IMPEDANCE AND TOMOGRAPHY IN IMPLANTS INSERTION IN LUMBAR ARTHRODESIS
title_full CORRELATION: IMPEDANCE AND TOMOGRAPHY IN IMPLANTS INSERTION IN LUMBAR ARTHRODESIS
title_fullStr CORRELATION: IMPEDANCE AND TOMOGRAPHY IN IMPLANTS INSERTION IN LUMBAR ARTHRODESIS
title_full_unstemmed CORRELATION: IMPEDANCE AND TOMOGRAPHY IN IMPLANTS INSERTION IN LUMBAR ARTHRODESIS
title_sort correlation: impedance and tomography in implants insertion in lumbar arthrodesis
publisher Sociedade Brasileira de Coluna (SBC)
series Coluna/Columna
issn 2177-014X
description ABSTRACT Objective: To define whether the electroneurophysiological stimulation would be a safe method for reducing injuries in nerve roots during surgery of lumbar spine arthrodesis, as well as verify whether there is a direct correlation between the intraoperative impedance values and the distance from the medial cortical pedicle screw. Methods: Randomized retrospective multicenter study of 10 patients who underwent arthrodesis of lumbar spine after conservative treatment failure, with a total of 50 pedicle screws instrumented. Reliable and safe impedance values were measured in order to reduce the risk of injury to nerve roots in the perioperative period, and these values were compared with the distance between the screw and the medial cortical of the pedicle by CT scan, measured in the immediate post-operative period. Results: There is no direct correlation between the intraoperative impedance values and the distance from the screw to the medial cortical of the pedicle. Conclusion: The electroneurostimulation proved to be a reliable quantitative method to reduce the risk of injury to nerve roots during surgery of lumbar spine arthrodesis when the measured values are greater than 10mA.
topic Artrodese
Impedância elétrica
Raízes nervosas espinhais
Estimulação elétrica.
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1808-18512016000400283&lng=en&tlng=en
work_keys_str_mv AT erikogoncalvesfilgueira correlationimpedanceandtomographyinimplantsinsertioninlumbararthrodesis
AT lucianodealmeidaferrer correlationimpedanceandtomographyinimplantsinsertioninlumbararthrodesis
AT itamaralvesbarbosaneto correlationimpedanceandtomographyinimplantsinsertioninlumbararthrodesis
AT leonardomoraispaiva correlationimpedanceandtomographyinimplantsinsertioninlumbararthrodesis
AT ricardosugai correlationimpedanceandtomographyinimplantsinsertioninlumbararthrodesis
AT lucianafeitosaferrer correlationimpedanceandtomographyinimplantsinsertioninlumbararthrodesis
_version_ 1725340956846194688