Technique, protocols and adverse reactions for contrast-enhanced spectral mammography (CESM): a systematic review
Abstract We reviewed technical parameters, acquisition protocols and adverse reactions (ARs) for contrast-enhanced spectral mammography (CESM). A systematic search in databases, including MEDLINE/EMBASE, was performed to extract publication year, country of origin, study design; patients; mammograph...
Main Authors: | , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
SpringerOpen
2019-08-01
|
Series: | Insights into Imaging |
Subjects: | |
Online Access: | http://link.springer.com/article/10.1186/s13244-019-0756-0 |
id |
doaj-8918aa1850584699b61ae13d0cbdc0a4 |
---|---|
record_format |
Article |
spelling |
doaj-8918aa1850584699b61ae13d0cbdc0a42020-11-25T03:50:04ZengSpringerOpenInsights into Imaging1869-41012019-08-0110111510.1186/s13244-019-0756-0Technique, protocols and adverse reactions for contrast-enhanced spectral mammography (CESM): a systematic reviewMoreno Zanardo0Andrea Cozzi1Rubina Manuela Trimboli2Olgerta Labaj3Caterina Beatrice Monti4Simone Schiaffino5Luca Alessandro Carbonaro6Francesco Sardanelli7Department of Biomedical Sciences for Health, Università degli Studi di MilanoDepartment of Biomedical Sciences for Health, Università degli Studi di MilanoDepartment of Biomedical Sciences for Health, Università degli Studi di MilanoDepartment of Morphology, Surgery and Experimental Medicine, Section of Radiology, University of FerraraDepartment of Biomedical Sciences for Health, Università degli Studi di MilanoUnit of Radiology, IRCCS Policlinico San DonatoUnit of Radiology, IRCCS Policlinico San DonatoDepartment of Biomedical Sciences for Health, Università degli Studi di MilanoAbstract We reviewed technical parameters, acquisition protocols and adverse reactions (ARs) for contrast-enhanced spectral mammography (CESM). A systematic search in databases, including MEDLINE/EMBASE, was performed to extract publication year, country of origin, study design; patients; mammography unit/vendor, radiation dose, low-/high-energy tube voltage; contrast molecule, concentration and dose; injection modality, ARs and acquisition delay; order of views; examination time. Of 120 retrieved articles, 84 were included from 22 countries (September 2003–January 2019), totalling 14012 patients. Design was prospective in 44/84 studies (52%); in 70/84 articles (83%), a General Electric unit with factory-set kVp was used. Per-view average glandular dose, reported in 12/84 studies (14%), ranged 0.43–2.65 mGy. Contrast type/concentration was reported in 79/84 studies (94%), with Iohexol 350 mgI/mL mostly used (25/79, 32%), dose and flow rate in 72/84 (86%), with 1.5 mL/kg dose at 3 mL/s in 62/72 studies (86%). Injection was described in 69/84 articles (82%), automated in 59/69 (85%), manual in 10/69 (15%) and flush in 35/84 (42%), with 10–30 mL dose in 19/35 (54%). An examination time < 10 min was reported in 65/84 studies (77%), 120 s acquisition delay in 65/84 (77%) and order of views in 42/84 (50%) studies, beginning with the craniocaudal view of the non-suspected breast in 7/42 (17%). Thirty ARs were reported by 14/84 (17%) studies (26 mild, 3 moderate, 1 severe non-fatal) with a pooled rate of 0.82% (fixed-effect model). Only half of CESM studies were prospective; factory-set kVp, contrast 1.5 mL/kg at 3 mL/s and 120 s acquisition delay were mostly used; only 1 severe AR was reported. CESM protocol standardisation is advisable.http://link.springer.com/article/10.1186/s13244-019-0756-0BreastContrast mediaDrug-related side effects and adverse reactionsMammographyRadiation dosage |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Moreno Zanardo Andrea Cozzi Rubina Manuela Trimboli Olgerta Labaj Caterina Beatrice Monti Simone Schiaffino Luca Alessandro Carbonaro Francesco Sardanelli |
spellingShingle |
Moreno Zanardo Andrea Cozzi Rubina Manuela Trimboli Olgerta Labaj Caterina Beatrice Monti Simone Schiaffino Luca Alessandro Carbonaro Francesco Sardanelli Technique, protocols and adverse reactions for contrast-enhanced spectral mammography (CESM): a systematic review Insights into Imaging Breast Contrast media Drug-related side effects and adverse reactions Mammography Radiation dosage |
author_facet |
Moreno Zanardo Andrea Cozzi Rubina Manuela Trimboli Olgerta Labaj Caterina Beatrice Monti Simone Schiaffino Luca Alessandro Carbonaro Francesco Sardanelli |
author_sort |
Moreno Zanardo |
title |
Technique, protocols and adverse reactions for contrast-enhanced spectral mammography (CESM): a systematic review |
title_short |
Technique, protocols and adverse reactions for contrast-enhanced spectral mammography (CESM): a systematic review |
title_full |
Technique, protocols and adverse reactions for contrast-enhanced spectral mammography (CESM): a systematic review |
title_fullStr |
Technique, protocols and adverse reactions for contrast-enhanced spectral mammography (CESM): a systematic review |
title_full_unstemmed |
Technique, protocols and adverse reactions for contrast-enhanced spectral mammography (CESM): a systematic review |
title_sort |
technique, protocols and adverse reactions for contrast-enhanced spectral mammography (cesm): a systematic review |
publisher |
SpringerOpen |
series |
Insights into Imaging |
issn |
1869-4101 |
publishDate |
2019-08-01 |
description |
Abstract We reviewed technical parameters, acquisition protocols and adverse reactions (ARs) for contrast-enhanced spectral mammography (CESM). A systematic search in databases, including MEDLINE/EMBASE, was performed to extract publication year, country of origin, study design; patients; mammography unit/vendor, radiation dose, low-/high-energy tube voltage; contrast molecule, concentration and dose; injection modality, ARs and acquisition delay; order of views; examination time. Of 120 retrieved articles, 84 were included from 22 countries (September 2003–January 2019), totalling 14012 patients. Design was prospective in 44/84 studies (52%); in 70/84 articles (83%), a General Electric unit with factory-set kVp was used. Per-view average glandular dose, reported in 12/84 studies (14%), ranged 0.43–2.65 mGy. Contrast type/concentration was reported in 79/84 studies (94%), with Iohexol 350 mgI/mL mostly used (25/79, 32%), dose and flow rate in 72/84 (86%), with 1.5 mL/kg dose at 3 mL/s in 62/72 studies (86%). Injection was described in 69/84 articles (82%), automated in 59/69 (85%), manual in 10/69 (15%) and flush in 35/84 (42%), with 10–30 mL dose in 19/35 (54%). An examination time < 10 min was reported in 65/84 studies (77%), 120 s acquisition delay in 65/84 (77%) and order of views in 42/84 (50%) studies, beginning with the craniocaudal view of the non-suspected breast in 7/42 (17%). Thirty ARs were reported by 14/84 (17%) studies (26 mild, 3 moderate, 1 severe non-fatal) with a pooled rate of 0.82% (fixed-effect model). Only half of CESM studies were prospective; factory-set kVp, contrast 1.5 mL/kg at 3 mL/s and 120 s acquisition delay were mostly used; only 1 severe AR was reported. CESM protocol standardisation is advisable. |
topic |
Breast Contrast media Drug-related side effects and adverse reactions Mammography Radiation dosage |
url |
http://link.springer.com/article/10.1186/s13244-019-0756-0 |
work_keys_str_mv |
AT morenozanardo techniqueprotocolsandadversereactionsforcontrastenhancedspectralmammographycesmasystematicreview AT andreacozzi techniqueprotocolsandadversereactionsforcontrastenhancedspectralmammographycesmasystematicreview AT rubinamanuelatrimboli techniqueprotocolsandadversereactionsforcontrastenhancedspectralmammographycesmasystematicreview AT olgertalabaj techniqueprotocolsandadversereactionsforcontrastenhancedspectralmammographycesmasystematicreview AT caterinabeatricemonti techniqueprotocolsandadversereactionsforcontrastenhancedspectralmammographycesmasystematicreview AT simoneschiaffino techniqueprotocolsandadversereactionsforcontrastenhancedspectralmammographycesmasystematicreview AT lucaalessandrocarbonaro techniqueprotocolsandadversereactionsforcontrastenhancedspectralmammographycesmasystematicreview AT francescosardanelli techniqueprotocolsandadversereactionsforcontrastenhancedspectralmammographycesmasystematicreview |
_version_ |
1724492546304901120 |