Validation of Modified ART Mod 2 Code through Comparison with Aerosol Deposition of Cesium Compound in Phébus FPT3 Containment Vessel

Evaluation of aerosol deposition in the containment vessel is an important step for the assessment of radioactive material release to the environment. ART Mod 2 is a calculation code that is used for evaluation of aerosol deposition in the containment vessel. The authors modified aerosol deposition...

Full description

Bibliographic Details
Main Authors: Wasin Vechgama, Kampanart Silva, Somboon Rassame
Format: Article
Language:English
Published: Hindawi Limited 2019-01-01
Series:Science and Technology of Nuclear Installations
Online Access:http://dx.doi.org/10.1155/2019/4081943
id doaj-88e80478075c4894a2bda366bcc81c90
record_format Article
spelling doaj-88e80478075c4894a2bda366bcc81c902020-11-24T21:56:46ZengHindawi LimitedScience and Technology of Nuclear Installations1687-60751687-60832019-01-01201910.1155/2019/40819434081943Validation of Modified ART Mod 2 Code through Comparison with Aerosol Deposition of Cesium Compound in Phébus FPT3 Containment VesselWasin Vechgama0Kampanart Silva1Somboon Rassame2Thailand Institute of Nuclear Technology (Public Organization), 9/9 Moo 7, Saimoon, Ongkharak, Nakhon Nayok, 26120, ThailandThailand Institute of Nuclear Technology (Public Organization), 9/9 Moo 7, Saimoon, Ongkharak, Nakhon Nayok, 26120, ThailandDepartment of Nuclear Engineering, Faculty of Engineering, Chulalongkorn University, 254 Phayathai Rd., Pathumwan, Bangkok, 10330, ThailandEvaluation of aerosol deposition in the containment vessel is an important step for the assessment of radioactive material release to the environment. ART Mod 2 is a calculation code that is used for evaluation of aerosol deposition in the containment vessel. The authors modified aerosol deposition models of ART Mod 2, namely, gravitational settling model, Brownian diffusion model, diffusiophoresis model, and thermophoresis model in order to increase potential of capturing the deposition phenomena. This study aims to compare the simulated results of modified ART Mod 2 with aerosol deposition of cesium compounds in the containment vessel of Phébus FPT3 experiment, in order to validate modified ART Mod 2 code. It is found that aerosol deposition using modified ART Mod 2 agrees with Phébus FPT3. Prediction of Brownian diffusion is significantly improved due to the consideration of turbulent damping process. Cesium mass flow rate and aerosol size are factors that can significantly influence the uncertainty of the results. When conditions of single volumes are carefully selected to match those of the Phébus FPT3 experiment, modified ART Mod 2 can predict aerosol deposition in Phébus FPT3 with relative accuracy.http://dx.doi.org/10.1155/2019/4081943
collection DOAJ
language English
format Article
sources DOAJ
author Wasin Vechgama
Kampanart Silva
Somboon Rassame
spellingShingle Wasin Vechgama
Kampanart Silva
Somboon Rassame
Validation of Modified ART Mod 2 Code through Comparison with Aerosol Deposition of Cesium Compound in Phébus FPT3 Containment Vessel
Science and Technology of Nuclear Installations
author_facet Wasin Vechgama
Kampanart Silva
Somboon Rassame
author_sort Wasin Vechgama
title Validation of Modified ART Mod 2 Code through Comparison with Aerosol Deposition of Cesium Compound in Phébus FPT3 Containment Vessel
title_short Validation of Modified ART Mod 2 Code through Comparison with Aerosol Deposition of Cesium Compound in Phébus FPT3 Containment Vessel
title_full Validation of Modified ART Mod 2 Code through Comparison with Aerosol Deposition of Cesium Compound in Phébus FPT3 Containment Vessel
title_fullStr Validation of Modified ART Mod 2 Code through Comparison with Aerosol Deposition of Cesium Compound in Phébus FPT3 Containment Vessel
title_full_unstemmed Validation of Modified ART Mod 2 Code through Comparison with Aerosol Deposition of Cesium Compound in Phébus FPT3 Containment Vessel
title_sort validation of modified art mod 2 code through comparison with aerosol deposition of cesium compound in phébus fpt3 containment vessel
publisher Hindawi Limited
series Science and Technology of Nuclear Installations
issn 1687-6075
1687-6083
publishDate 2019-01-01
description Evaluation of aerosol deposition in the containment vessel is an important step for the assessment of radioactive material release to the environment. ART Mod 2 is a calculation code that is used for evaluation of aerosol deposition in the containment vessel. The authors modified aerosol deposition models of ART Mod 2, namely, gravitational settling model, Brownian diffusion model, diffusiophoresis model, and thermophoresis model in order to increase potential of capturing the deposition phenomena. This study aims to compare the simulated results of modified ART Mod 2 with aerosol deposition of cesium compounds in the containment vessel of Phébus FPT3 experiment, in order to validate modified ART Mod 2 code. It is found that aerosol deposition using modified ART Mod 2 agrees with Phébus FPT3. Prediction of Brownian diffusion is significantly improved due to the consideration of turbulent damping process. Cesium mass flow rate and aerosol size are factors that can significantly influence the uncertainty of the results. When conditions of single volumes are carefully selected to match those of the Phébus FPT3 experiment, modified ART Mod 2 can predict aerosol deposition in Phébus FPT3 with relative accuracy.
url http://dx.doi.org/10.1155/2019/4081943
work_keys_str_mv AT wasinvechgama validationofmodifiedartmod2codethroughcomparisonwithaerosoldepositionofcesiumcompoundinphebusfpt3containmentvessel
AT kampanartsilva validationofmodifiedartmod2codethroughcomparisonwithaerosoldepositionofcesiumcompoundinphebusfpt3containmentvessel
AT somboonrassame validationofmodifiedartmod2codethroughcomparisonwithaerosoldepositionofcesiumcompoundinphebusfpt3containmentvessel
_version_ 1725857289712173056