Validation of Modified ART Mod 2 Code through Comparison with Aerosol Deposition of Cesium Compound in Phébus FPT3 Containment Vessel

Evaluation of aerosol deposition in the containment vessel is an important step for the assessment of radioactive material release to the environment. ART Mod 2 is a calculation code that is used for evaluation of aerosol deposition in the containment vessel. The authors modified aerosol deposition...

Full description

Bibliographic Details
Main Authors: Wasin Vechgama, Kampanart Silva, Somboon Rassame
Format: Article
Language:English
Published: Hindawi Limited 2019-01-01
Series:Science and Technology of Nuclear Installations
Online Access:http://dx.doi.org/10.1155/2019/4081943
Description
Summary:Evaluation of aerosol deposition in the containment vessel is an important step for the assessment of radioactive material release to the environment. ART Mod 2 is a calculation code that is used for evaluation of aerosol deposition in the containment vessel. The authors modified aerosol deposition models of ART Mod 2, namely, gravitational settling model, Brownian diffusion model, diffusiophoresis model, and thermophoresis model in order to increase potential of capturing the deposition phenomena. This study aims to compare the simulated results of modified ART Mod 2 with aerosol deposition of cesium compounds in the containment vessel of Phébus FPT3 experiment, in order to validate modified ART Mod 2 code. It is found that aerosol deposition using modified ART Mod 2 agrees with Phébus FPT3. Prediction of Brownian diffusion is significantly improved due to the consideration of turbulent damping process. Cesium mass flow rate and aerosol size are factors that can significantly influence the uncertainty of the results. When conditions of single volumes are carefully selected to match those of the Phébus FPT3 experiment, modified ART Mod 2 can predict aerosol deposition in Phébus FPT3 with relative accuracy.
ISSN:1687-6075