The experience of using magnetic resonance imaging of the uterus and its appendages as an alternative to X-ray hysterosalpingography
Objective. Determination of the diagnostic capabilities of magnetic resonance imaging of the uterus and its appendages (MRHSG) on devices with the induction of the magnetic field 3 Tesla (T) as an alternative to the classic X-ray hysterosalpingography, accompanied by a significant radiation dose to...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
LUCHEVAYA DIAGNOSTIKA, LLC
2016-11-01
|
Series: | Вестник рентгенологии и радиологии |
Subjects: | |
Online Access: | https://www.russianradiology.ru/jour/article/view/165 |
id |
doaj-88d07c5a940b4b568c48ff24f4e874a0 |
---|---|
record_format |
Article |
spelling |
doaj-88d07c5a940b4b568c48ff24f4e874a02021-09-15T15:32:23ZengLUCHEVAYA DIAGNOSTIKA, LLCВестник рентгенологии и радиологии0042-46762619-04782016-11-0197526827310.20862/0042-4676-2016-97-5-268-273141The experience of using magnetic resonance imaging of the uterus and its appendages as an alternative to X-ray hysterosalpingographyA. F. Akhatov0S. A. Ryzhkin1M. K. Mikhaylov2Kazan State Medical Academy, Ministry of Health of the RF, ul. Mushtari, 11, Kazan, 420012, Russian FederationKazan State Medical Academy, Ministry of Health of the RF, ul. Mushtari, 11, Kazan, 420012, Russian FederationKazan State Medical Academy, Ministry of Health of the RF, ul. Mushtari, 11, Kazan, 420012, Russian FederationObjective. Determination of the diagnostic capabilities of magnetic resonance imaging of the uterus and its appendages (MRHSG) on devices with the induction of the magnetic field 3 Tesla (T) as an alternative to the classic X-ray hysterosalpingography, accompanied by a significant radiation dose to the patient.Material and methods. During the period from April 2015 to February 2016 12 MRHSG was conducted using magnetic resonance imaging apparatus Verio Magnetom 3T, Siemens company (Diagnostic Center "BarsMed", Kazan, Russia). We used neutral and not giving adverse reactions contrast agent – carbon dioxide. The pelvic organs – the uterus and fallopian tubes – represent the zone of interest.Results. Analysis of the data showed that MRHSG on the apparatus with the induction of the magnetic field of 3 T is a highly informative method in the diagnosis of tubal patency, allowing fully assess the state of the pelvic organs on the whole and identify pathology.The absence of radiation exposure and contraindications associated with intolerance to iodinated contrast agents and other side effects differs MRHSG from the traditional X-ray method and makes MRHSG to be an alternative secure method of diagnosis, which has a number of advantages described in the article.Conclusions. MRHSG on the apparatus with the induction of the magnetic field of 3 T in diagnosis of obstruction of the fallopian tubes and the visualization of the uterus and appendages diseases can be optimal and safe alternative to the X-ray hysterosalpingography, which accompanied with radiation exposure and is a number of side effects.https://www.russianradiology.ru/jour/article/view/165magnetic resonance imaginguterushysterosalpingographyradiation protection of patients |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
A. F. Akhatov S. A. Ryzhkin M. K. Mikhaylov |
spellingShingle |
A. F. Akhatov S. A. Ryzhkin M. K. Mikhaylov The experience of using magnetic resonance imaging of the uterus and its appendages as an alternative to X-ray hysterosalpingography Вестник рентгенологии и радиологии magnetic resonance imaging uterus hysterosalpingography radiation protection of patients |
author_facet |
A. F. Akhatov S. A. Ryzhkin M. K. Mikhaylov |
author_sort |
A. F. Akhatov |
title |
The experience of using magnetic resonance imaging of the uterus and its appendages as an alternative to X-ray hysterosalpingography |
title_short |
The experience of using magnetic resonance imaging of the uterus and its appendages as an alternative to X-ray hysterosalpingography |
title_full |
The experience of using magnetic resonance imaging of the uterus and its appendages as an alternative to X-ray hysterosalpingography |
title_fullStr |
The experience of using magnetic resonance imaging of the uterus and its appendages as an alternative to X-ray hysterosalpingography |
title_full_unstemmed |
The experience of using magnetic resonance imaging of the uterus and its appendages as an alternative to X-ray hysterosalpingography |
title_sort |
experience of using magnetic resonance imaging of the uterus and its appendages as an alternative to x-ray hysterosalpingography |
publisher |
LUCHEVAYA DIAGNOSTIKA, LLC |
series |
Вестник рентгенологии и радиологии |
issn |
0042-4676 2619-0478 |
publishDate |
2016-11-01 |
description |
Objective. Determination of the diagnostic capabilities of magnetic resonance imaging of the uterus and its appendages (MRHSG) on devices with the induction of the magnetic field 3 Tesla (T) as an alternative to the classic X-ray hysterosalpingography, accompanied by a significant radiation dose to the patient.Material and methods. During the period from April 2015 to February 2016 12 MRHSG was conducted using magnetic resonance imaging apparatus Verio Magnetom 3T, Siemens company (Diagnostic Center "BarsMed", Kazan, Russia). We used neutral and not giving adverse reactions contrast agent – carbon dioxide. The pelvic organs – the uterus and fallopian tubes – represent the zone of interest.Results. Analysis of the data showed that MRHSG on the apparatus with the induction of the magnetic field of 3 T is a highly informative method in the diagnosis of tubal patency, allowing fully assess the state of the pelvic organs on the whole and identify pathology.The absence of radiation exposure and contraindications associated with intolerance to iodinated contrast agents and other side effects differs MRHSG from the traditional X-ray method and makes MRHSG to be an alternative secure method of diagnosis, which has a number of advantages described in the article.Conclusions. MRHSG on the apparatus with the induction of the magnetic field of 3 T in diagnosis of obstruction of the fallopian tubes and the visualization of the uterus and appendages diseases can be optimal and safe alternative to the X-ray hysterosalpingography, which accompanied with radiation exposure and is a number of side effects. |
topic |
magnetic resonance imaging uterus hysterosalpingography radiation protection of patients |
url |
https://www.russianradiology.ru/jour/article/view/165 |
work_keys_str_mv |
AT afakhatov theexperienceofusingmagneticresonanceimagingoftheuterusanditsappendagesasanalternativetoxrayhysterosalpingography AT saryzhkin theexperienceofusingmagneticresonanceimagingoftheuterusanditsappendagesasanalternativetoxrayhysterosalpingography AT mkmikhaylov theexperienceofusingmagneticresonanceimagingoftheuterusanditsappendagesasanalternativetoxrayhysterosalpingography AT afakhatov experienceofusingmagneticresonanceimagingoftheuterusanditsappendagesasanalternativetoxrayhysterosalpingography AT saryzhkin experienceofusingmagneticresonanceimagingoftheuterusanditsappendagesasanalternativetoxrayhysterosalpingography AT mkmikhaylov experienceofusingmagneticresonanceimagingoftheuterusanditsappendagesasanalternativetoxrayhysterosalpingography |
_version_ |
1717378768574611456 |