Evaluation of properties of AISI 431Grade Stainless Steel by Vacuum Annealing Process
The wear behaviour of AISI 431stainless steel was investigated at consistent load under a dry sliding touch with vacuum annealing device. The approach implemented was found to have been effective in improving the wear actions of stainless steel products, advancing the pliability properties. For Vacu...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2020-01-01
|
Series: | E3S Web of Conferences |
Online Access: | https://www.e3s-conferences.org/articles/e3sconf/pdf/2020/44/e3sconf_icmed2020_01021.pdf |
id |
doaj-88b5d4367e944288b5c6b932adda11b9 |
---|---|
record_format |
Article |
spelling |
doaj-88b5d4367e944288b5c6b932adda11b92021-04-02T17:40:41ZengEDP SciencesE3S Web of Conferences2267-12422020-01-011840102110.1051/e3sconf/202018401021e3sconf_icmed2020_01021Evaluation of properties of AISI 431Grade Stainless Steel by Vacuum Annealing ProcessLakshmi Prasanna Gandla0Keerthi Reddy G.1Ram Subbiah Dr.2PG Student, Mechanical department, Gokaraju Rangaraju Institute of Engineering and TechnologyPG Student, Mechanical department, Gokaraju Rangaraju Institute of Engineering and TechnologyAssociate Professor, Mechanical Department, Gokaraju Rangaraju Institute of Engineering and TechnologyThe wear behaviour of AISI 431stainless steel was investigated at consistent load under a dry sliding touch with vacuum annealing device. The approach implemented was found to have been effective in improving the wear actions of stainless steel products, advancing the pliability properties. For Vacuum Annealed (VA1) 2 hours, Vacuum Annealed (VA2) 4 hours and Vacuum Annealed (VA3) 6 hours respectively, a low temperature heat treatment was performed on sample for the maximum annealing cycle. Untreated stainless steel (UNT) was used as a kind of viewpoint tool for contrast with specific hardening samples and conducted wear checks. The hardening samples show certain hard formed layers which enhance the hardness of the surface. Estimations of small scale toughness showed a crucial improvement in toughness following operation. This method raises the hardness of the substance up to 150 percent. A pin on the disc drive is used to do wear checking to assess wear failure. The layers were represented by optical lens magnification and the examination of electron magnifying glass.https://www.e3s-conferences.org/articles/e3sconf/pdf/2020/44/e3sconf_icmed2020_01021.pdf |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Lakshmi Prasanna Gandla Keerthi Reddy G. Ram Subbiah Dr. |
spellingShingle |
Lakshmi Prasanna Gandla Keerthi Reddy G. Ram Subbiah Dr. Evaluation of properties of AISI 431Grade Stainless Steel by Vacuum Annealing Process E3S Web of Conferences |
author_facet |
Lakshmi Prasanna Gandla Keerthi Reddy G. Ram Subbiah Dr. |
author_sort |
Lakshmi Prasanna Gandla |
title |
Evaluation of properties of AISI 431Grade Stainless Steel by Vacuum Annealing Process |
title_short |
Evaluation of properties of AISI 431Grade Stainless Steel by Vacuum Annealing Process |
title_full |
Evaluation of properties of AISI 431Grade Stainless Steel by Vacuum Annealing Process |
title_fullStr |
Evaluation of properties of AISI 431Grade Stainless Steel by Vacuum Annealing Process |
title_full_unstemmed |
Evaluation of properties of AISI 431Grade Stainless Steel by Vacuum Annealing Process |
title_sort |
evaluation of properties of aisi 431grade stainless steel by vacuum annealing process |
publisher |
EDP Sciences |
series |
E3S Web of Conferences |
issn |
2267-1242 |
publishDate |
2020-01-01 |
description |
The wear behaviour of AISI 431stainless steel was investigated at consistent load under a dry sliding touch with vacuum annealing device. The approach implemented was found to have been effective in improving the wear actions of stainless steel products, advancing the pliability properties. For Vacuum Annealed (VA1) 2 hours, Vacuum Annealed (VA2) 4 hours and Vacuum Annealed (VA3) 6 hours respectively, a low temperature heat treatment was performed on sample for the maximum annealing cycle. Untreated stainless steel (UNT) was used as a kind of viewpoint tool for contrast with specific hardening samples and conducted wear checks. The hardening samples show certain hard formed layers which enhance the hardness of the surface. Estimations of small scale toughness showed a crucial improvement in toughness following operation. This method raises the hardness of the substance up to 150 percent. A pin on the disc drive is used to do wear checking to assess wear failure. The layers were represented by optical lens magnification and the examination of electron magnifying glass. |
url |
https://www.e3s-conferences.org/articles/e3sconf/pdf/2020/44/e3sconf_icmed2020_01021.pdf |
work_keys_str_mv |
AT lakshmiprasannagandla evaluationofpropertiesofaisi431gradestainlesssteelbyvacuumannealingprocess AT keerthireddyg evaluationofpropertiesofaisi431gradestainlesssteelbyvacuumannealingprocess AT ramsubbiahdr evaluationofpropertiesofaisi431gradestainlesssteelbyvacuumannealingprocess |
_version_ |
1721553605068062720 |