Application of Variable Weight Coefficient Method in State Evaluation of AC Contactor
AC contactor state evaluation is a challenging problem. This paper proposes an AC contactor state assessment method based on variable weight coefficient. Firstly, the characteristic indicators that have a great influence on the state of the AC contactor are selected, and the state evaluation index s...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2018-01-01
|
Series: | MATEC Web of Conferences |
Online Access: | https://doi.org/10.1051/matecconf/201823203041 |
id |
doaj-88942fad9ee94b538370edb154e5b2ba |
---|---|
record_format |
Article |
spelling |
doaj-88942fad9ee94b538370edb154e5b2ba2021-03-02T09:54:59ZengEDP SciencesMATEC Web of Conferences2261-236X2018-01-012320304110.1051/matecconf/201823203041matecconf_eitce2018_03041Application of Variable Weight Coefficient Method in State Evaluation of AC ContactorSu Yuze0Liu Zichun1Gao Kai2Na Guangyu3Liu Shuxin4Northeast Electric Power UniversityInstitute of Electrical Apparatus New Technology and Application, Shenyang University of TechnologyLiaoning Provincial Electric Power Co., Ltd. Electric Power Research InstituteLiaoning Provincial Electric Power Co., Ltd. Electric Power Research InstituteInstitute of Electrical Apparatus New Technology and Application, Shenyang University of TechnologyAC contactor state evaluation is a challenging problem. This paper proposes an AC contactor state assessment method based on variable weight coefficient. Firstly, the characteristic indicators that have a great influence on the state of the AC contactor are selected, and the state evaluation index system is established. Secondly, using the subjective and objective combination weighting method combined with the analytic hierarchy process and the grey relational analysis method, the constant weight coefficient is obtained, and the variable weight coefficient method with the equalization function is introduced to obtain the variable weight coefficient of each characteristic parameter. Finally, the fuzzy comprehensive evaluation method is used to evaluate the running state of the AC contactor. The experimental results show that the state evaluation method proposed in this paper can accurately reflect the real state of the AC contactor operation and effectively improve the reliability of the power system.https://doi.org/10.1051/matecconf/201823203041 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Su Yuze Liu Zichun Gao Kai Na Guangyu Liu Shuxin |
spellingShingle |
Su Yuze Liu Zichun Gao Kai Na Guangyu Liu Shuxin Application of Variable Weight Coefficient Method in State Evaluation of AC Contactor MATEC Web of Conferences |
author_facet |
Su Yuze Liu Zichun Gao Kai Na Guangyu Liu Shuxin |
author_sort |
Su Yuze |
title |
Application of Variable Weight Coefficient Method in State Evaluation of AC Contactor |
title_short |
Application of Variable Weight Coefficient Method in State Evaluation of AC Contactor |
title_full |
Application of Variable Weight Coefficient Method in State Evaluation of AC Contactor |
title_fullStr |
Application of Variable Weight Coefficient Method in State Evaluation of AC Contactor |
title_full_unstemmed |
Application of Variable Weight Coefficient Method in State Evaluation of AC Contactor |
title_sort |
application of variable weight coefficient method in state evaluation of ac contactor |
publisher |
EDP Sciences |
series |
MATEC Web of Conferences |
issn |
2261-236X |
publishDate |
2018-01-01 |
description |
AC contactor state evaluation is a challenging problem. This paper proposes an AC contactor state assessment method based on variable weight coefficient. Firstly, the characteristic indicators that have a great influence on the state of the AC contactor are selected, and the state evaluation index system is established. Secondly, using the subjective and objective combination weighting method combined with the analytic hierarchy process and the grey relational analysis method, the constant weight coefficient is obtained, and the variable weight coefficient method with the equalization function is introduced to obtain the variable weight coefficient of each characteristic parameter. Finally, the fuzzy comprehensive evaluation method is used to evaluate the running state of the AC contactor. The experimental results show that the state evaluation method proposed in this paper can accurately reflect the real state of the AC contactor operation and effectively improve the reliability of the power system. |
url |
https://doi.org/10.1051/matecconf/201823203041 |
work_keys_str_mv |
AT suyuze applicationofvariableweightcoefficientmethodinstateevaluationofaccontactor AT liuzichun applicationofvariableweightcoefficientmethodinstateevaluationofaccontactor AT gaokai applicationofvariableweightcoefficientmethodinstateevaluationofaccontactor AT naguangyu applicationofvariableweightcoefficientmethodinstateevaluationofaccontactor AT liushuxin applicationofvariableweightcoefficientmethodinstateevaluationofaccontactor |
_version_ |
1724238123095818240 |