Application of Solid Phase Microextraction (SPME) Sampler for Determination of Carbon Disulfide in Air

Carbon disulfide is used predominantly in the manufacture. It has affects the nervous system. In this study, the applicability of SPME as a passive sampler for determination of carbon disulphide in air was studied. Effect of sampler and environmental parameters on uptake of Carbon disulphide was st...

Full description

Bibliographic Details
Main Authors: Abdul Rahman Bahrami, Farshid Ghorbani, Hadi Baiati, Mohammad Javad Zare-Sakhvidi
Format: Article
Language:English
Published: Tehran University of Medical Sciences 2015-10-01
Series:International Journal of Occupational Hygiene
Subjects:
Online Access:https://ijoh.tums.ac.ir/index.php/ijoh/article/view/112
id doaj-88932c76254640a3834d8d063ccf5a2f
record_format Article
spelling doaj-88932c76254640a3834d8d063ccf5a2f2020-12-07T08:39:28ZengTehran University of Medical SciencesInternational Journal of Occupational Hygiene2008-51092008-54352015-10-0163112Application of Solid Phase Microextraction (SPME) Sampler for Determination of Carbon Disulfide in AirAbdul Rahman Bahrami0Farshid Ghorbani1Hadi Baiati2Mohammad Javad Zare-Sakhvidi3Excellence Centre for Occupational Health, Research Centre for Health Sciences, School of Public Health, Hamadan University of Medical Science, Hamadan, Iran.Department of Occupational Health Engineering, Research Centre for Health Sciences, School of Public, Health, Hamadan University of Medical Science, Hamadan, Iran.Department of Occupational Health Engineering, Research Centre for Health Sciences, School of Public, Health, Hamadan University of Medical Science, Hamadan, Iran.Department of Occupational Health, Faculty of Health Engineering, ShahidSadoughi University of Medical Sciences,Yazd, Iran. Carbon disulfide is used predominantly in the manufacture. It has affects the nervous system. In this study, the applicability of SPME as a passive sampler for determination of carbon disulphide in air was studied. Effect of sampler and environmental parameters on uptake of Carbon disulphide was studied as well. Four fibers were tested to select the best sampler for determine carbon disulfide in ambient air. A standard generation chamber was built in the laboratory and was used to test the SPME. Analysis SPME samples were carried out by a gas chromatography-Mass spectrometry and results were compared with data obtained with National Institute for Occupational Safety and Health (NIOSH) method 1600. Polymethylsiloxane-carboxen (PDMS/CAR) showed  the  most  effective stationary phase  material for sorbing BTEX among other materials (polyacrylate, PDMS, PDMS/divinylbenzene). Its linearity range in exposed mode was less than 10 minutes but with its retracted mode application, its linearity increased up to 8 hours. Temperature had not linear effect on uptake of pollutant in temperatures lower than 25, it has positive effect and above this range it has negative effect. Relative humidity had negative effect on mass loaded on fiber. Velocity in range of static to 0.5 m/s had no significant effect. The precision of the method was 4.18% relative standard deviation (RSD). The detection limit for carbon disulfide in the GC/MS system in SIM mode was 6.7 ng per sample. SPME is a good alternative for sampling of carbon disulfide in air. However, for the situations in high humidity values it should be used with care. https://ijoh.tums.ac.ir/index.php/ijoh/article/view/112Carbon disulphideAir samplingGas chromatographySolid phase microextraction
collection DOAJ
language English
format Article
sources DOAJ
author Abdul Rahman Bahrami
Farshid Ghorbani
Hadi Baiati
Mohammad Javad Zare-Sakhvidi
spellingShingle Abdul Rahman Bahrami
Farshid Ghorbani
Hadi Baiati
Mohammad Javad Zare-Sakhvidi
Application of Solid Phase Microextraction (SPME) Sampler for Determination of Carbon Disulfide in Air
International Journal of Occupational Hygiene
Carbon disulphide
Air sampling
Gas chromatography
Solid phase microextraction
author_facet Abdul Rahman Bahrami
Farshid Ghorbani
Hadi Baiati
Mohammad Javad Zare-Sakhvidi
author_sort Abdul Rahman Bahrami
title Application of Solid Phase Microextraction (SPME) Sampler for Determination of Carbon Disulfide in Air
title_short Application of Solid Phase Microextraction (SPME) Sampler for Determination of Carbon Disulfide in Air
title_full Application of Solid Phase Microextraction (SPME) Sampler for Determination of Carbon Disulfide in Air
title_fullStr Application of Solid Phase Microextraction (SPME) Sampler for Determination of Carbon Disulfide in Air
title_full_unstemmed Application of Solid Phase Microextraction (SPME) Sampler for Determination of Carbon Disulfide in Air
title_sort application of solid phase microextraction (spme) sampler for determination of carbon disulfide in air
publisher Tehran University of Medical Sciences
series International Journal of Occupational Hygiene
issn 2008-5109
2008-5435
publishDate 2015-10-01
description Carbon disulfide is used predominantly in the manufacture. It has affects the nervous system. In this study, the applicability of SPME as a passive sampler for determination of carbon disulphide in air was studied. Effect of sampler and environmental parameters on uptake of Carbon disulphide was studied as well. Four fibers were tested to select the best sampler for determine carbon disulfide in ambient air. A standard generation chamber was built in the laboratory and was used to test the SPME. Analysis SPME samples were carried out by a gas chromatography-Mass spectrometry and results were compared with data obtained with National Institute for Occupational Safety and Health (NIOSH) method 1600. Polymethylsiloxane-carboxen (PDMS/CAR) showed  the  most  effective stationary phase  material for sorbing BTEX among other materials (polyacrylate, PDMS, PDMS/divinylbenzene). Its linearity range in exposed mode was less than 10 minutes but with its retracted mode application, its linearity increased up to 8 hours. Temperature had not linear effect on uptake of pollutant in temperatures lower than 25, it has positive effect and above this range it has negative effect. Relative humidity had negative effect on mass loaded on fiber. Velocity in range of static to 0.5 m/s had no significant effect. The precision of the method was 4.18% relative standard deviation (RSD). The detection limit for carbon disulfide in the GC/MS system in SIM mode was 6.7 ng per sample. SPME is a good alternative for sampling of carbon disulfide in air. However, for the situations in high humidity values it should be used with care.
topic Carbon disulphide
Air sampling
Gas chromatography
Solid phase microextraction
url https://ijoh.tums.ac.ir/index.php/ijoh/article/view/112
work_keys_str_mv AT abdulrahmanbahrami applicationofsolidphasemicroextractionspmesamplerfordeterminationofcarbondisulfideinair
AT farshidghorbani applicationofsolidphasemicroextractionspmesamplerfordeterminationofcarbondisulfideinair
AT hadibaiati applicationofsolidphasemicroextractionspmesamplerfordeterminationofcarbondisulfideinair
AT mohammadjavadzaresakhvidi applicationofsolidphasemicroextractionspmesamplerfordeterminationofcarbondisulfideinair
_version_ 1724397726214389760