A comparison between GafchromicTM EBT3 film and Delta4® phantom in IMRT technique of a heterogeneous chest phantom

Introdution: In advanced radiotherapy techniques such as intensity modulated radiation therapy (IMRT), the quality assurance (QA) is essential. This study aimed to compare the performance between GafchromicTM EBT3 film and Delta4® phantom (2D and 3D) in heterogeneous chest phantom using IMRT...

Full description

Bibliographic Details
Main Authors: Razzagh Abedi Firouzjah, Abolfazl Nickfarjam, Mohsen Bakhshandeh
Format: Article
Language:fas
Published: Shahid Sadoughi University of Medical Sciences 2018-05-01
Series:Majallah-i Dānishgāh-i ’Ulūm-i Pizishkī-i Shahīd Ṣadūqī Yazd
Subjects:
Online Access:http://jssu.ssu.ac.ir/browse.php?a_code=A-10-3400-1&slc_lang=en&sid=1
id doaj-886e9f52f0d149fdb12489247aee034d
record_format Article
spelling doaj-886e9f52f0d149fdb12489247aee034d2020-11-25T00:15:37ZfasShahid Sadoughi University of Medical SciencesMajallah-i Dānishgāh-i ’Ulūm-i Pizishkī-i Shahīd Ṣadūqī Yazd2228-57412228-57332018-05-01262177187A comparison between GafchromicTM EBT3 film and Delta4® phantom in IMRT technique of a heterogeneous chest phantomRazzagh Abedi Firouzjah0Abolfazl Nickfarjam1Mohsen Bakhshandeh2 Department of Medical Physics, Faculty of medicine, Shahid Sadoughi University of Medical Sciences, Yazd, Iran Radiotherapy research center, shahid sadoughi university of medical sciences, yazd, Iran Radiation Technology Department, Allied Medical Sciences Faculty, Shahid Beheshti University of Medical Sciences, Tehran, Iran Introdution: In advanced radiotherapy techniques such as intensity modulated radiation therapy (IMRT), the quality assurance (QA) is essential. This study aimed to compare the performance between GafchromicTM EBT3 film and Delta4® phantom (2D and 3D) in heterogeneous chest phantom using IMRT technique. Methods: In this experimental study, two IMRT plans (A and B) were prepared for radiotherapy of heterogeneous chest phantom. EBT3 film and Delta4 were used for dose measurement in the phantom. The 95% global gamma index accepted by the criteria of  3.3% mm and the dose threshold 20% as the standard criteria were considered in this study. The gamma index of the film and Delta4 were acquired by the verisoft and Delta4 software, respectively. Results: The mean gamma index with standard criteria between treatment planning system (TPS) dose calculations and film measurements was 96.95%, while it was equal to 97.7% and 98.45% between TPS calculations and 2D and 3D Delta4 cases, respectively. The mean 3D gamma analysis of the Delta4 with the given standard criteria was 0.75% and 1.5% higher than their 2D gamma analysis of the Delta4 and film, respectively. The mean gamma index value of film and Delta4 according to the plan B at the standard criteria was 0.24% higher than plan A (97.7% vs 97.46%). Conclusion: Both film and Delta4 showed acceptable standard gamma index for two plans implemented on the chest phantom using IMRT technique. So, according to the results of this study, it is concluded that in the centers where Delta4 is not available, EBT3 films with a simple heterogeneous phantom can be an alternative method.http://jssu.ssu.ac.ir/browse.php?a_code=A-10-3400-1&slc_lang=en&sid=1IMRT technique Gafchromic EBT3 film Delta4 Phantom Gamma index
collection DOAJ
language fas
format Article
sources DOAJ
author Razzagh Abedi Firouzjah
Abolfazl Nickfarjam
Mohsen Bakhshandeh
spellingShingle Razzagh Abedi Firouzjah
Abolfazl Nickfarjam
Mohsen Bakhshandeh
A comparison between GafchromicTM EBT3 film and Delta4® phantom in IMRT technique of a heterogeneous chest phantom
Majallah-i Dānishgāh-i ’Ulūm-i Pizishkī-i Shahīd Ṣadūqī Yazd
IMRT technique
Gafchromic EBT3 film
Delta4 Phantom
Gamma index
author_facet Razzagh Abedi Firouzjah
Abolfazl Nickfarjam
Mohsen Bakhshandeh
author_sort Razzagh Abedi Firouzjah
title A comparison between GafchromicTM EBT3 film and Delta4® phantom in IMRT technique of a heterogeneous chest phantom
title_short A comparison between GafchromicTM EBT3 film and Delta4® phantom in IMRT technique of a heterogeneous chest phantom
title_full A comparison between GafchromicTM EBT3 film and Delta4® phantom in IMRT technique of a heterogeneous chest phantom
title_fullStr A comparison between GafchromicTM EBT3 film and Delta4® phantom in IMRT technique of a heterogeneous chest phantom
title_full_unstemmed A comparison between GafchromicTM EBT3 film and Delta4® phantom in IMRT technique of a heterogeneous chest phantom
title_sort comparison between gafchromictm ebt3 film and delta4® phantom in imrt technique of a heterogeneous chest phantom
publisher Shahid Sadoughi University of Medical Sciences
series Majallah-i Dānishgāh-i ’Ulūm-i Pizishkī-i Shahīd Ṣadūqī Yazd
issn 2228-5741
2228-5733
publishDate 2018-05-01
description Introdution: In advanced radiotherapy techniques such as intensity modulated radiation therapy (IMRT), the quality assurance (QA) is essential. This study aimed to compare the performance between GafchromicTM EBT3 film and Delta4® phantom (2D and 3D) in heterogeneous chest phantom using IMRT technique. Methods: In this experimental study, two IMRT plans (A and B) were prepared for radiotherapy of heterogeneous chest phantom. EBT3 film and Delta4 were used for dose measurement in the phantom. The 95% global gamma index accepted by the criteria of  3.3% mm and the dose threshold 20% as the standard criteria were considered in this study. The gamma index of the film and Delta4 were acquired by the verisoft and Delta4 software, respectively. Results: The mean gamma index with standard criteria between treatment planning system (TPS) dose calculations and film measurements was 96.95%, while it was equal to 97.7% and 98.45% between TPS calculations and 2D and 3D Delta4 cases, respectively. The mean 3D gamma analysis of the Delta4 with the given standard criteria was 0.75% and 1.5% higher than their 2D gamma analysis of the Delta4 and film, respectively. The mean gamma index value of film and Delta4 according to the plan B at the standard criteria was 0.24% higher than plan A (97.7% vs 97.46%). Conclusion: Both film and Delta4 showed acceptable standard gamma index for two plans implemented on the chest phantom using IMRT technique. So, according to the results of this study, it is concluded that in the centers where Delta4 is not available, EBT3 films with a simple heterogeneous phantom can be an alternative method.
topic IMRT technique
Gafchromic EBT3 film
Delta4 Phantom
Gamma index
url http://jssu.ssu.ac.ir/browse.php?a_code=A-10-3400-1&slc_lang=en&sid=1
work_keys_str_mv AT razzaghabedifirouzjah acomparisonbetweengafchromictmebt3filmanddelta4phantominimrttechniqueofaheterogeneouschestphantom
AT abolfazlnickfarjam acomparisonbetweengafchromictmebt3filmanddelta4phantominimrttechniqueofaheterogeneouschestphantom
AT mohsenbakhshandeh acomparisonbetweengafchromictmebt3filmanddelta4phantominimrttechniqueofaheterogeneouschestphantom
AT razzaghabedifirouzjah comparisonbetweengafchromictmebt3filmanddelta4phantominimrttechniqueofaheterogeneouschestphantom
AT abolfazlnickfarjam comparisonbetweengafchromictmebt3filmanddelta4phantominimrttechniqueofaheterogeneouschestphantom
AT mohsenbakhshandeh comparisonbetweengafchromictmebt3filmanddelta4phantominimrttechniqueofaheterogeneouschestphantom
_version_ 1725385857862467584