Establishing a Customized Guide Plate for Osteotomy in Total Knee Arthroplasty Using Lower-extremity X-ray and Knee Computed Tomography Images
Background: The conventional method cannot guarantee the precise osteotomies required for a perfect realignment and a better prognosis after total knee arthroplasty (TKA). This study investigated a customized guide plate for osteotomy placement in TKAs with the aid of the statistical shape model tec...
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wolters Kluwer
2016-01-01
|
Series: | Chinese Medical Journal |
Subjects: | |
Online Access: | http://www.cmj.org/article.asp?issn=0366-6999;year=2016;volume=129;issue=4;spage=386;epage=391;aulast=Zhang |
id |
doaj-8833f7efa53d47e8ad10ab3aba2f5b51 |
---|---|
record_format |
Article |
spelling |
doaj-8833f7efa53d47e8ad10ab3aba2f5b512020-11-25T02:25:53ZengWolters KluwerChinese Medical Journal0366-69992016-01-01129438639110.4103/0366-6999.176082Establishing a Customized Guide Plate for Osteotomy in Total Knee Arthroplasty Using Lower-extremity X-ray and Knee Computed Tomography ImagesJin ZhangXiao-Bin TianLi SunRu-Yin HuJia-Liang TianWei HanJin-Min ZhaoBackground: The conventional method cannot guarantee the precise osteotomies required for a perfect realignment and a better prognosis after total knee arthroplasty (TKA). This study investigated a customized guide plate for osteotomy placement in TKAs with the aid of the statistical shape model technique using weight-bearing lower-extremity X-rays and computed tomography (CT) images of the knee. Methods: From October 2014 to June 2015, 42 patients who underwent a TKA in Guizhou Provincial People's Hospital were divided into a guide plate group (GPG, 21 cases) and a traditional surgery group (TSG, 21 cases) using a random number table method. In the GPG group, a guide plate was designed and printed using preoperative three-dimensional measurements to plan and digitally simulate the operation. TSG cases were treated with the conventional method. Outcomes were obtained from the postoperative image examination and short-term follow-up. Results: Operative time was 49.0 ± 10.5 min for GPG, and 62.0 ± 9.7 min in TSG. The coronal femoral angle, coronal tibial angle, posterior tibial slope, and the angle between the posterior condylar osteotomy surface and the surgical transepicondylar axis were 89.2 ± 1.7°, 89.0 ± 1.1°, 6.6 ± 1.4°, and 0.9 ± 0.3° in GPG, and 86.7 ± 2.9°, 87.6 ± 2.1°, 8.9 ± 2.8°, and 1.7 ± 0.8° in TSG, respectively. The Hospital for Special Surgery scores 3 months after surgery were 83.7 ± 18.4 in GPG and 71.5 ± 15.2 in TSG. Statistically significant differences were found between GPG and TSG in all measurements. Conclusions: A customized guide plate to create an accurate osteotomy in TKAs may be created using lower-extremity X-ray and knee CT images. This allows for shorter operative times and better postoperative alignment than the traditional surgery. Application of the digital guide plate may also result in better short-term outcomes.http://www.cmj.org/article.asp?issn=0366-6999;year=2016;volume=129;issue=4;spage=386;epage=391;aulast=ZhangDigital; Guide Plate for Osteotomy; Lower-extremity X-ray; Statistical Shape Model; Total Knee Arthroplasty |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Jin Zhang Xiao-Bin Tian Li Sun Ru-Yin Hu Jia-Liang Tian Wei Han Jin-Min Zhao |
spellingShingle |
Jin Zhang Xiao-Bin Tian Li Sun Ru-Yin Hu Jia-Liang Tian Wei Han Jin-Min Zhao Establishing a Customized Guide Plate for Osteotomy in Total Knee Arthroplasty Using Lower-extremity X-ray and Knee Computed Tomography Images Chinese Medical Journal Digital; Guide Plate for Osteotomy; Lower-extremity X-ray; Statistical Shape Model; Total Knee Arthroplasty |
author_facet |
Jin Zhang Xiao-Bin Tian Li Sun Ru-Yin Hu Jia-Liang Tian Wei Han Jin-Min Zhao |
author_sort |
Jin Zhang |
title |
Establishing a Customized Guide Plate for Osteotomy in Total Knee Arthroplasty Using Lower-extremity X-ray and Knee Computed Tomography Images |
title_short |
Establishing a Customized Guide Plate for Osteotomy in Total Knee Arthroplasty Using Lower-extremity X-ray and Knee Computed Tomography Images |
title_full |
Establishing a Customized Guide Plate for Osteotomy in Total Knee Arthroplasty Using Lower-extremity X-ray and Knee Computed Tomography Images |
title_fullStr |
Establishing a Customized Guide Plate for Osteotomy in Total Knee Arthroplasty Using Lower-extremity X-ray and Knee Computed Tomography Images |
title_full_unstemmed |
Establishing a Customized Guide Plate for Osteotomy in Total Knee Arthroplasty Using Lower-extremity X-ray and Knee Computed Tomography Images |
title_sort |
establishing a customized guide plate for osteotomy in total knee arthroplasty using lower-extremity x-ray and knee computed tomography images |
publisher |
Wolters Kluwer |
series |
Chinese Medical Journal |
issn |
0366-6999 |
publishDate |
2016-01-01 |
description |
Background: The conventional method cannot guarantee the precise osteotomies required for a perfect realignment and a better prognosis after total knee arthroplasty (TKA). This study investigated a customized guide plate for osteotomy placement in TKAs with the aid of the statistical shape model technique using weight-bearing lower-extremity X-rays and computed tomography (CT) images of the knee.
Methods: From October 2014 to June 2015, 42 patients who underwent a TKA in Guizhou Provincial People's Hospital were divided into a guide plate group (GPG, 21 cases) and a traditional surgery group (TSG, 21 cases) using a random number table method. In the GPG group, a guide plate was designed and printed using preoperative three-dimensional measurements to plan and digitally simulate the operation. TSG cases were treated with the conventional method. Outcomes were obtained from the postoperative image examination and short-term follow-up.
Results: Operative time was 49.0 ± 10.5 min for GPG, and 62.0 ± 9.7 min in TSG. The coronal femoral angle, coronal tibial angle, posterior tibial slope, and the angle between the posterior condylar osteotomy surface and the surgical transepicondylar axis were 89.2 ± 1.7°, 89.0 ± 1.1°, 6.6 ± 1.4°, and 0.9 ± 0.3° in GPG, and 86.7 ± 2.9°, 87.6 ± 2.1°, 8.9 ± 2.8°, and 1.7 ± 0.8° in TSG, respectively. The Hospital for Special Surgery scores 3 months after surgery were 83.7 ± 18.4 in GPG and 71.5 ± 15.2 in TSG. Statistically significant differences were found between GPG and TSG in all measurements.
Conclusions: A
customized guide plate to create an accurate osteotomy in TKAs may be created using lower-extremity X-ray and knee CT images. This allows for shorter operative times and better postoperative alignment than the traditional surgery. Application of the digital guide plate may also result in better short-term outcomes. |
topic |
Digital; Guide Plate for Osteotomy; Lower-extremity X-ray; Statistical Shape Model; Total Knee Arthroplasty |
url |
http://www.cmj.org/article.asp?issn=0366-6999;year=2016;volume=129;issue=4;spage=386;epage=391;aulast=Zhang |
work_keys_str_mv |
AT jinzhang establishingacustomizedguideplateforosteotomyintotalkneearthroplastyusinglowerextremityxrayandkneecomputedtomographyimages AT xiaobintian establishingacustomizedguideplateforosteotomyintotalkneearthroplastyusinglowerextremityxrayandkneecomputedtomographyimages AT lisun establishingacustomizedguideplateforosteotomyintotalkneearthroplastyusinglowerextremityxrayandkneecomputedtomographyimages AT ruyinhu establishingacustomizedguideplateforosteotomyintotalkneearthroplastyusinglowerextremityxrayandkneecomputedtomographyimages AT jialiangtian establishingacustomizedguideplateforosteotomyintotalkneearthroplastyusinglowerextremityxrayandkneecomputedtomographyimages AT weihan establishingacustomizedguideplateforosteotomyintotalkneearthroplastyusinglowerextremityxrayandkneecomputedtomographyimages AT jinminzhao establishingacustomizedguideplateforosteotomyintotalkneearthroplastyusinglowerextremityxrayandkneecomputedtomographyimages |
_version_ |
1724849795481206784 |