Monitoring of praseodymium(III) ions in aqueous solutions, soil and sediment samples by a PVC membrane sensor based on a furan-triazole derivative
A furan-triazole derivative has been explored as an ionophore for preparation of a highly selective Pr(III) membrane sensor. The proposed sensor exhibits a Nernstian response for Pr(III) activity over a wide concentration range with a detection limit of 5.2×10-8 M. Its response is independent of pH...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Sociedade Brasileira de Química
2012-01-01
|
Series: | Química Nova |
Subjects: | |
Online Access: | http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422012001000016&lng=en&tlng=en |
id |
doaj-87d80ec394c942939a52b157ee3ef532 |
---|---|
record_format |
Article |
spelling |
doaj-87d80ec394c942939a52b157ee3ef5322020-11-24T21:44:50ZengSociedade Brasileira de QuímicaQuímica Nova1678-70642012-01-0135101973198010.1590/S0100-40422012001000016S0100-40422012001000016Monitoring of praseodymium(III) ions in aqueous solutions, soil and sediment samples by a PVC membrane sensor based on a furan-triazole derivativeMohammad Reza Pourjavid0Mohammad Rezaee1Majid Haji Hosseini2Taherehsadat Razavi3Nuclear Science & Technology Research InstituteNuclear Science & Technology Research InstituteNuclear Science & Technology Research InstituteResearch Institute of PetroleumA furan-triazole derivative has been explored as an ionophore for preparation of a highly selective Pr(III) membrane sensor. The proposed sensor exhibits a Nernstian response for Pr(III) activity over a wide concentration range with a detection limit of 5.2×10-8 M. Its response is independent of pH of the solution in the range 3.0-8.8 and offers the advantages of fast response time. To investigate the analytical applicability of the sensor, it was applied successfully as an indicator electrode in potentiometric titration of Pr(III) solution and also in the direct and indirect determination of trace Pr(III) ions in some samples.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422012001000016&lng=en&tlng=enmembrane sensorPr(III) selectivefuran-triazole derivative |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Mohammad Reza Pourjavid Mohammad Rezaee Majid Haji Hosseini Taherehsadat Razavi |
spellingShingle |
Mohammad Reza Pourjavid Mohammad Rezaee Majid Haji Hosseini Taherehsadat Razavi Monitoring of praseodymium(III) ions in aqueous solutions, soil and sediment samples by a PVC membrane sensor based on a furan-triazole derivative Química Nova membrane sensor Pr(III) selective furan-triazole derivative |
author_facet |
Mohammad Reza Pourjavid Mohammad Rezaee Majid Haji Hosseini Taherehsadat Razavi |
author_sort |
Mohammad Reza Pourjavid |
title |
Monitoring of praseodymium(III) ions in aqueous solutions, soil and sediment samples by a PVC membrane sensor based on a furan-triazole derivative |
title_short |
Monitoring of praseodymium(III) ions in aqueous solutions, soil and sediment samples by a PVC membrane sensor based on a furan-triazole derivative |
title_full |
Monitoring of praseodymium(III) ions in aqueous solutions, soil and sediment samples by a PVC membrane sensor based on a furan-triazole derivative |
title_fullStr |
Monitoring of praseodymium(III) ions in aqueous solutions, soil and sediment samples by a PVC membrane sensor based on a furan-triazole derivative |
title_full_unstemmed |
Monitoring of praseodymium(III) ions in aqueous solutions, soil and sediment samples by a PVC membrane sensor based on a furan-triazole derivative |
title_sort |
monitoring of praseodymium(iii) ions in aqueous solutions, soil and sediment samples by a pvc membrane sensor based on a furan-triazole derivative |
publisher |
Sociedade Brasileira de Química |
series |
Química Nova |
issn |
1678-7064 |
publishDate |
2012-01-01 |
description |
A furan-triazole derivative has been explored as an ionophore for preparation of a highly selective Pr(III) membrane sensor. The proposed sensor exhibits a Nernstian response for Pr(III) activity over a wide concentration range with a detection limit of 5.2×10-8 M. Its response is independent of pH of the solution in the range 3.0-8.8 and offers the advantages of fast response time. To investigate the analytical applicability of the sensor, it was applied successfully as an indicator electrode in potentiometric titration of Pr(III) solution and also in the direct and indirect determination of trace Pr(III) ions in some samples. |
topic |
membrane sensor Pr(III) selective furan-triazole derivative |
url |
http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422012001000016&lng=en&tlng=en |
work_keys_str_mv |
AT mohammadrezapourjavid monitoringofpraseodymiumiiiionsinaqueoussolutionssoilandsedimentsamplesbyapvcmembranesensorbasedonafurantriazolederivative AT mohammadrezaee monitoringofpraseodymiumiiiionsinaqueoussolutionssoilandsedimentsamplesbyapvcmembranesensorbasedonafurantriazolederivative AT majidhajihosseini monitoringofpraseodymiumiiiionsinaqueoussolutionssoilandsedimentsamplesbyapvcmembranesensorbasedonafurantriazolederivative AT taherehsadatrazavi monitoringofpraseodymiumiiiionsinaqueoussolutionssoilandsedimentsamplesbyapvcmembranesensorbasedonafurantriazolederivative |
_version_ |
1725908563921993728 |